3D Printed Smart Silk Wearable Sensors

The Analyst ◽  
2021 ◽  
Author(s):  
Tianshu Chu ◽  
Huili Wang ◽  
Yumeng Qiu ◽  
Haoxi Luo ◽  
Bingfang He ◽  
...  

Wearable sensors play a key role in point-of-care testing (POCT) for its flexible and integration capability on sensitive physiological and biochemical sensing. Here, we present a multifunction wearable silk patch...

Sensors ◽  
2021 ◽  
Vol 21 (5) ◽  
pp. 1796
Author(s):  
Miroslav Pohanka ◽  
Jitka Zakova

Acetylcholinesterase (AChE) and butyrylcholinesterase (BChE) can serve as biochemical markers of various pathologies like liver disfunction and poisonings by nerve agents. Ellman’s assay is the standard spectrophotometric method to measure cholinesterase activity in clinical laboratories. The authors present a new colorimetric test to assess AChE and BChE activity in biological samples using chromogenic reagents, treated 3D-printed measuring pads and a smartphone camera as a signal detector. Multiwell pads treated with reagent substrates 2,6-dichlorophenolindophenyl acetate, indoxylacetate, ethoxyresorufin and methoxyresorufin were prepared and tested for AChE and BChE. In the experiments, 3D-printed pads containing indoxylacetate as a chromogenic substrate were optimal for analytical purposes. The best results were achieved using the red (R) channel, where the limit of detection was 4.05 µkat/mL for BChE and 4.38 µkat/mL for AChE using a 40 µL sample and a 60 min assay. The major advantage of this method is its overall simplicity, as samples are applied directly without any specific treatment or added reagents. The assay was also validated to the standard Ellman’s assay using human plasma samples. In conclusion, this smartphone camera-based colorimetric assay appears to have practical applicability and to be a suitable method for point-of-care testing because it does not require specific manipulation, additional education of staff or use of sophisticated analytical instruments.


Author(s):  
Neil Vaughan ◽  
Venketesh N. Dubey ◽  
Tamas Hickish ◽  
Jonathan Cole

This paper presents a patented smart point-of-care testing (POCT) system for the diagnosis and grading of peripheral neuropathy at the patient’s home or care center. The device aims to detect changes or worsening of a patient’s neuropathy. Our system utilizes the vibration motor within a smartphone, applied through a 3D printed probe attachment to detect sensation loss in vibration sensitivity threshold (VST). A smartphone app displays several neuropathy questionnaires to the user to identify and monitor changes in their condition. This paper presents results from comparison between the new smart device and the gold standard Neurothesiometer. Results suggest that the new device performs closely to the gold standard in terms of the frequency and amplitude of vibration.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Arthur Zargaryan ◽  
Nathalie Farhoudi ◽  
George Haworth ◽  
Julian F. Ashby ◽  
Sam H. Au

Abstract 3D printed and paper-based microfluidics are promising formats for applications that require portable miniaturized fluid handling such as point-of-care testing. These two formats deployed in isolation, however, have inherent limitations that hamper their capabilities and versatility. Here, we present the convergence of 3D printed and paper formats into hybrid devices that overcome many of these limitations, while capitalizing on their respective strengths. Hybrid channels were fabricated with no specialized equipment except a commercial 3D printer. Finger-operated reservoirs and valves capable of fully-reversible dispensation and actuation were designed for intuitive operation without equipment or training. Components were then integrated into a versatile multicomponent device capable of dynamic fluid pathing. These results are an early demonstration of how 3D printed and paper microfluidics can be hybridized into versatile lab-on-chip devices.


2020 ◽  
Vol 27 ◽  
Author(s):  
Yi Zhang

: Point-of-care (POC) testing decentralizes the diagnostic tests to the sites near the patient. Many POC tests rely microfluidic platforms for sample-to-answer analysis. Compared to other microfluidic systems, magnetic digital microfluidics demonstrate compelling advantages for POC diagnostics. In this review, we have examined the capability of magnetic digital microfluidics-based POC diagnostic platforms. More importantly, we have categorized POC settings into three classes based on “where is the point”, “who to care” and “how to test”, and evaluated the suitability of magnetic digital microfluidics in various POC settings. Furthermore, we have addressed other technical issues associated with POC testing such as controlled environment, sample-system interface, system integration and information connectivity. We hope this review would provide a guideline for the future development of magnetic digital microfluidics-based platforms for POC testing.