In situ spectroscopic evidence for facile, carbon monoxide mediated, reversible cleavage of neutral heterobimetallic rhodium–ruthenium complexes into ionic mononuclear complexes

1996 ◽  
pp. 2061-2062 ◽  
Author(s):  
Phillip S. Bearman ◽  
Anthony K. Smith ◽  
Nicola C. Tong ◽  
Robin Whyman
Author(s):  
Thulani M. Nyathi ◽  
Mohamed I. Fadlalla ◽  
Nico Fischer ◽  
Andrew P.E. York ◽  
Ezra J. Olivier ◽  
...  

1985 ◽  
Vol 40 (10) ◽  
pp. 1243-1249 ◽  
Author(s):  
Henri Brunner ◽  
Alfons Knott

The chelate phosphanes Diphos, Diop, and Norphos were reacted with C5H5Mn(CO)2THF and CH3C5H4Mn(CO)2THF to give mononuclear complexes, containing the phosphanes as unidentate or as bidentate ligands, and dinuclear complexes, containing bridging phosphane ligands. In C5H5Mn(CO)2Diop one of the two P(C6H5)2 groups of Diop is coordinated to the C5H5Mn(CO)2 fragment; the uncoordinated P(C6H5)2 group makes it a monodentate ligand. C5H5Mn(CO)2Diop together with [Rh(cod)Cl]2 was used as an in situ catalyst in the enantioselective hydrogenation of (Z)-a-[N -acetam ino]cinnamic acid (78.4% ee) and in the enantioselective hydrosilylation of acetophenone with diphenylsilane (6.7% ee).


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Lian Wang ◽  
Juncheng Zhou ◽  
Yuhao Chen ◽  
Liu Xiao ◽  
Guojia Huang ◽  
...  

Abstract An intensity modulated fiber-optic carbon monoxide (CO) sensor by integrating in-situ solvothermal-growth Ag/Co-MOF sensing film is fabricated and evaluated. The Michelson interference sensing structure is composed of single-mode fiber (SMF), enlarged taper, thin-core fiber (TCF), and Ag film as the reflector. Ag/Co-MOF was coated on the cladding of the TCF as the sensing material, and the enlarged taper is located between TCF and SMF as the coupler. The structure, morphology, compositions and thermal stability of the Ag/Co-MOF sensing film were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS), thermogravimetric analysis (TGA), etc. The sensitivity of the sensor is 0.04515 dB/ppm, and the fitting parameter of the CO concentration is 0.99876. In addition, the sensor has the advantages of good selectivity, good signal and temperature stability, and it has potential application in trace CO detection.


2021 ◽  
Vol 62 (1) ◽  
pp. 160-171
Author(s):  
A. M. Kremneva ◽  
A. V. Fedorov ◽  
A. A. Saraev ◽  
O. A. Bulavchenko ◽  
V. A. Yakovlev ◽  
...  

Carbon ◽  
2020 ◽  
Vol 158 ◽  
pp. 110-120
Author(s):  
Junsung Hong ◽  
Youngjin Ko ◽  
Kwang-Yeon Cho ◽  
Dong-Geun Shin ◽  
Prabhakar Singh ◽  
...  

2019 ◽  
Vol 21 (21) ◽  
pp. 11079-11086 ◽  
Author(s):  
C. Karthika ◽  
S. R. Sarath Kumar ◽  
L. Kathuria ◽  
P. K. Das ◽  
A. G. Samuelson

Reversible redox switching of first hyperpolarizability of Monometallic and bimetallic complex.


Sign in / Sign up

Export Citation Format

Share Document