scholarly journals TiO2 doped chitosan/hydroxyapatite/halloysite nanotube membranes with enhanced mechanical properties and osteoblast-like cell response for application in bone tissue engineering

RSC Advances ◽  
2019 ◽  
Vol 9 (68) ◽  
pp. 39768-39779
Author(s):  
Sarim Khan ◽  
Viney Kumar ◽  
Partha Roy ◽  
Patit Paban Kundu

This two-stage study aims to optimize the amount of halloysite nanotubes and TiO2 in a chitosan/nano-hydroxyapatite composite to tailor the mechanical and biological properties for application in bone tissue engineering.

2015 ◽  
Vol 3 (23) ◽  
pp. 4679-4689 ◽  
Author(s):  
Ya-Ping Guo ◽  
Jun-Jie Guan ◽  
Jun Yang ◽  
Yang Wang ◽  
Chang-Qing Zhang ◽  
...  

A bioinspired strategy has been developed to fabricate a hybrid nanostructured hydroxyapatite–chitosan composite scaffold for bone tissue engineering.


2019 ◽  
Vol 819 ◽  
pp. 9-14 ◽  
Author(s):  
Kanharit Wongsawichai ◽  
Arada Kingkaew ◽  
Aninart Pariyaisut ◽  
Supang Khondee

Bone tissue engineering is an alternative approach to generate bone using biomaterials and cells. Hydroxyapatite (HA) has good biocompatibility, osteoinductivity, and osteoconductivity. However, it has limited utility due to poor mechanical properties and slow degradation rate. To improve mechanical properties and to modify degradation profile, hydroxyapatite was tethered in chitosan (CS) and carboxymethyl cellulose (CMC) complex. Gelatin was incorporated to promote cell attachment and polyvinyl alcohol (PVA) was used to improve mechanical strength of this scaffold. The physico-mechanical and biological properties of these scaffolds were investigated. Fourier transform infrared (FTIR) analysis and X-ray diffraction (XRD) showed the incorporation of hydroxyapatite in polymer matrix. The scaffolds had density, compressive strength, and Young’s modulus in the range of 0.24-0.30 g/cm3, 0.028-0.035 MPa, 0.178-0.560 MPa, respectively. The scaffolds had porosity of 69-91 percent. Higher content of PVA decreased porosity of scaffolds. Scanning electron microscope showed porous microstructure with pore size in the range of 60-183 μm. In vitro test on MC3T3-E1 preosteoblast cells showed negligible cytotoxicity of scaffolds. The data suggested that HA/CS/CMC/gelatin/PVA scaffold has potential applications in bone tissue engineering.


Author(s):  
Linus H. Leung ◽  
Saba Mortazavi ◽  
Sheldon M. Dick ◽  
Hani E. Naguib

Tissue engineering is an emerging alternative treatment for various diseases and injuries. The use of hydroxapatite composites for bioscaffolds has shown to improve the osteoconductivity. Studies in the literature have been performed to examine the advantages of using this composite in the biological aspects of tissue engineering; however, few studies have been on the synthesis and mechanical properties of these bioscaffolds. These properties are especially important in load bearing applications like in bone tissue engineering. In this study, poly(DL-lactide-co-glycolide) acid (PLGA) and hydroxyapatite (HA) were used to fabricate gas-foamed/salt leached scaffolds. Micro and nano-scaled HA particles were melt-compounded with PLGA using a twin-screw compounder. The composite material was dry blended with salt particles at a salt-to-polymer mass ratio of 5:1. From observations of micrographs taken with a scanning electron microscope, both the micro and nano-HA particles were shown to be well dispersed within the polymer matrix. The thermal properties were examined using differential scanning calorimetry, and the effect of the compositions on the glass transition temperature, Tg, was studied. The Tg was not significantly changed with the addition of HA particles from 0 to 20 wt%. Similarly, thermogravimetric analysis showed that the thermal degradation temperature remained at approximately 320 °C. The mechanical properties of the scaffolds were tested in compression. At the same composition, the scaffolds fabricated with the nano-HA showed an increase in modulus and strength. The results found in this study are important in developing novel biodegradable scaffolds with a focus on improving the mechanical properties of the scaffolds for bone tissue engineering applications.


RSC Advances ◽  
2015 ◽  
Vol 5 (74) ◽  
pp. 60188-60198 ◽  
Author(s):  
R. Govindan ◽  
G. Suresh Kumar ◽  
E. K. Girija

Biopolymer coated PG/HA composite scaffolds were prepared with enhanced mechanical properties for bone tissue engineering applications.


Author(s):  
Mariane Beatriz Sordi ◽  
Ariadne Cristiane Cabral da Cruz ◽  
Águedo Aragones ◽  
Mabel Mariela Rodríguez Cordeiro ◽  
Ricardo de Souza Magini

The aim of this study was to synthesize, characterize, and evaluate degradation and biocompatibility of poly(lactic-co-glycolic acid) + hydroxyapatite / β-tricalcium phosphate (PLGA+HA/βTCP) scaffolds incorporating simvastatin (SIM) to verify if this biomaterial might be promising for bone tissue engineering. Samples were obtained by the solvent evaporation technique. Biphasic ceramic particles (70% HA, 30% βTCP) were added to PLGA in a ratio of 1:1. Samples with SIM received 1% (m:m) of this medication. Scaffolds were synthesized in a cylindric-shape and sterilized by ethylene oxide. For degradation analysis, samples were immersed in PBS at 37 °C under constant stirring for 7, 14, 21, and 28 days. Non-degraded samples were taken as reference. Mass variation, scanning electron microscopy, porosity analysis, Fourier transform infrared spectroscopy, differential scanning calorimetry, and thermogravimetry were performed to evaluate physico-chemical properties. Wettability and cytotoxicity tests were conducted to evaluate the biocompatibility. Microscopic images revealed the presence of macro, meso, and micropores in the polymer structure with HA/βTCP particles homogeneously dispersed. Chemical and thermal analyses presented very similar results for both PLGA+HA/βTCP and PLGA+HA/βTCP+SIM. The incorporation of simvastatin improved the hydrophilicity of scaffolds. Additionally, PLGA+HA/βTCP and PLGA+HA/βTCP+SIM scaffolds were biocompatible for osteoblasts and mesenchymal stem cells. In summary, PLGA+HA/βTCP scaffolds incorporating simvastatin presented adequate structural, chemical, thermal, and biological properties for bone tissue engineering.


Nanomaterials ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 1319
Author(s):  
Muhammad Umar Aslam Khan ◽  
Wafa Shamsan Al-Arjan ◽  
Mona Saad Binkadem ◽  
Hassan Mehboob ◽  
Adnan Haider ◽  
...  

Bone tissue engineering is an advanced field for treatment of fractured bones to restore/regulate biological functions. Biopolymeric/bioceramic-based hybrid nanocomposite scaffolds are potential biomaterials for bone tissue because of biodegradable and biocompatible characteristics. We report synthesis of nanocomposite based on acrylic acid (AAc)/guar gum (GG), nano-hydroxyapatite (HAp NPs), titanium nanoparticles (TiO2 NPs), and optimum graphene oxide (GO) amount via free radical polymerization method. Porous scaffolds were fabricated through freeze-drying technique and coated with silver sulphadiazine. Different techniques were used to investigate functional group, crystal structural properties, morphology/elemental properties, porosity, and mechanical properties of fabricated scaffolds. Results show that increasing amount of TiO2 in combination with optimized GO has improved physicochemical and microstructural properties, mechanical properties (compressive strength (2.96 to 13.31 MPa) and Young’s modulus (39.56 to 300.81 MPa)), and porous properties (pore size (256.11 to 107.42 μm) and porosity (79.97 to 44.32%)). After 150 min, silver sulfadiazine release was found to be ~94.1%. In vitro assay of scaffolds also exhibited promising results against mouse pre-osteoblast (MC3T3-E1) cell lines. Hence, these fabricated scaffolds would be potential biomaterials for bone tissue engineering in biomedical engineering.


2005 ◽  
Vol 898 ◽  
Author(s):  
Devendra Verma ◽  
Rahul Bhowmik ◽  
Bedabibhas Mohanty ◽  
Dinesh R Katti ◽  
Kalpana S Katti

AbstractInterfaces play an important role in controlling the mechanical properties of composites. Optimum mechanical strength of scaffolds is of prime importance for bone tissue engineering. In the present work, molecular dynamics simulations and experimental studies have been conducted to study effect of interfacial interactions on mechanical properties of composites for bone replacement. In order to mimic biological processes, hydroxyapatite (HAP) is mineralized in presence of polyacrylic acid (PAAc) (in situ HAP). Further, solid and porous composites of in situ HAP with polycaprolactone (PCL) are made. Mechanical tests of composites of in situ HAP with PAAc have shown improved strain recovery, higher modulus/density ratio and also improved mechanical response in simulated body fluid (SBF). Simulation studies indicate potential for calcium bridging between –COO− of PAAc and surface calcium of HAP. This fact is also supported by infrared spectroscopic studies. PAAc modified surfaces of in situ HAP offer means to control the microstructure and mechanical response of porous composites. Nanoindentation experiments indicate that apatite grown on in situ HAP/PCL composites from SBF has improved elastic modulus and hardness. This work gives insight into the interfacial mechanisms responsible for mechanical response as well as bioactivity in biomaterials.


Sign in / Sign up

Export Citation Format

Share Document