scholarly journals A fluorescent and colorimetric probe based on naphthalene diimide and its high sensitivity towards copper ions when used as test strips

RSC Advances ◽  
2019 ◽  
Vol 9 (22) ◽  
pp. 12675-12680 ◽  
Author(s):  
Luyi Zong ◽  
Can Wang ◽  
Yuchen Song ◽  
Jie Hu ◽  
Qianqian Li ◽  
...  

A red fluorescent and colorimetric probe (NDI-Py) exhibited high selectivity and sensitivity towards copper ions both in solution and on silica gel plates.

The Analyst ◽  
2016 ◽  
Vol 141 (3) ◽  
pp. 832-835 ◽  
Author(s):  
Mian Wang ◽  
Yanglei Yuan ◽  
Hongmei Wang ◽  
Zhaohai Qin

A coumarin based probe that contains oxime-ether (1) shows high selectivity and high sensitivity for Pd2+ in pure water and can ratiometrically image Pd2+ in living cells.


2021 ◽  
Vol 9 (7) ◽  
pp. 1811-1820
Author(s):  
Shuang Yan ◽  
Bin Luo ◽  
Jia He ◽  
Fang Lan ◽  
Yao Wu

Novel bimetallic metal–organic framework nanocomposites were fabricated by a facile yet efficient method. The as-prepared nanomaterial exhibited high sensitivity and high selectivity toward phosphopeptides and good reusability of five cycles for enriching phosphopeptides.


2015 ◽  
Vol 1095 ◽  
pp. 341-344 ◽  
Author(s):  
Can Hui Xu ◽  
Guang Liang Zhang ◽  
Xin Zhou ◽  
Xi Lin Xiao ◽  
Chang Ming Nie ◽  
...  

The characterization of phosphoproteins requires highly specific methods for the separation and enrichment of phosphopeptides. Here we report a novel metal ion-immobilized solid phase material for the separation and enrichment of phosphopeptides. The material is uranyl-salophen-silica gel (USSG) particles in which salophen is a tetradentate ligand of uranyl ion. In USSG salophen is connected on the surface of silica gel and uranyl is bound on the surface through its coordination with salophen. Phosphopeptides can be selectively retained by USSG because uranyl-salophen can bind phosphate moiety with strong affinity and high selectivity. The new material USSG has been successfully used for the separation of phosphopeptides from peptide mixtures with the separation efficiency of 97.0% to 97.4%.


2021 ◽  
Author(s):  
Feng Gao ◽  
Xiaolong Tu ◽  
Yongfang Yu ◽  
Yansha Gao ◽  
Jin Zou ◽  
...  

Abstract Herein, an efficient electrochemical sensing platform is proposed for selective and sensitive detection of nitrite on the basis of Cu@C@Zeolitic imidazolate framework-8 (Cu@C@ZIF-8) heterostructure. Core-shell Cu@C@ZIF-8 composite was synthesized by pyrolysis of Cu-metal-organic framework@ZIF-8 (Cu-MOF@ZIF-8) in Ar atmosphere on account of the difference of thermal stability between Cu-MOF and ZIF-8. For the sensing system of Cu@C@ZIF-8, ZIF-8 with proper pore size allows nitrite diffuse through the shell, while big molecules cannot, which ensures high selectivity of the sensor. On the other hand, Cu@C as electrocatalyst promotes the oxidation of nitrite, thereby resulting high sensitivity of the sensor. Accordingly, the Cu@C@ZIF-8 based sensor presents excellent performance for nitrite detection, which achieves a wide linear response range of 0.1 µM to 300.0 µM, and a low limit of detection (LOD) of 0.033 µM. In addition, the Cu@C@ZIF-8 sensor possesses excellent stability and reproducibility, and was employed to quantify nitrite in sausage samples with recoveries of 95.45-104.80%.


RSC Advances ◽  
2021 ◽  
Vol 11 (47) ◽  
pp. 29466-29485
Author(s):  
Eunike Hamukwaya ◽  
Johannes Naimhwaka ◽  
Veikko Uahengo

A ditopic multi-colorimetric probe based on the phenylpridyl-thioic moiety (EN) was synthesized via a Schiff base reaction mechanism and characterized using 1H NMR and UV-vis spectroscopy.


Revista Vitae ◽  
2021 ◽  
Vol 28 (3) ◽  
Author(s):  
Laura Carvajal Barbosa ◽  
Diego Insuasty Cepeda ◽  
Andrés Felipe León Torres ◽  
Maria Mercedes Arias Cortes ◽  
Zuly Jenny Rivera Monroy ◽  
...  

BACKGROUND : Biosensing techniques have been the subject of exponentially increasing interest due to their performance advantages such as high selectivity and sensitivity, easy operation, low cost, short analysis time, simple sample preparation, and real-time detection. Biosensors have been developed by integrating the unique specificity of biological reactions and the high sensitivity of physical sensors. Therefore, there has been a broad scope of applications for biosensing techniques, and nowadays, they are ubiquitous in different areas of environmental, healthcare, and food safety. Biosensors have been used for environmental studies, detecting and quantifying pollutants in water, air, and soil. Biosensors also showed great potential for developing analytical tools with countless applications in diagnosing, preventing, and treating diseases, mainly by detecting biomarkers. Biosensors as a medical device can identify nucleic acids, proteins, peptides, metabolites, etc.; these analytes may be biomarkers associated with the disease status. Bacterial food contamination is considered a worldwide public health issue; biosensor-based analytical techniques can identify the presence or absence of pathogenic agents in food. OBJECTIVES: The present review aims to establish state-of-the-art, comprising the recent advances in the use of nucleic acid-based biosensors and their novel application for the detection of nucleic acids. Emphasis will be given to the performance characteristics, advantages, and challenges. Additionally, food safety applications of nucleic acid-based biosensors will be discussed. METHODS: Recent research articles related to nucleic acid-based biosensors, biosensors for detecting nucleic acids, biosensors and food safety, and biosensors in environmental monitoring were reviewed. Also, biosensing platforms associated with the clinical diagnosis and food industry were included. RESULTS: It is possible to appreciate that multiple applications of nucleic acid-based biosensors have been reported in the diagnosis, prevention, and treatment of diseases, as well as to identify foodborne pathogenic bacteria. The use of PNA and aptamers opens the possibility of developing new biometric tools with better analytical properties. CONCLUSIONS: Biosensors could be considered the most important tool for preventing, treating, and monitoring diseases that significantly impact human health. The aptamers have advantages as biorecognition elements due to the structural conformation, hybridization capacity, robustness, stability, and lower costs. It is necessary to implement biosensors in situ to identify analytes with high selectivity and lower detection limits.


RSC Advances ◽  
2016 ◽  
Vol 6 (32) ◽  
pp. 27130-27135 ◽  
Author(s):  
Xiao-Bin Cheng ◽  
Hui Li ◽  
Feng Zheng ◽  
Qi Lin ◽  
Hong Yao ◽  
...  

By a deprotonated mechanism, the simple chemosensorHYshowed high sensitivity and selectivity for cyanide in aqueous media.


Nanomaterials ◽  
2018 ◽  
Vol 9 (1) ◽  
pp. 32 ◽  
Author(s):  
Zhezhe Wang ◽  
Xuechun Xiao ◽  
Tong Zou ◽  
Yue Yang ◽  
Xinxin Xing ◽  
...  

Citric acid capped CdS quantum dots (CA-CdS QDs), a new assembled fluorescent probe for copper ions (Cu2+), was synthesized successfully by a simple hydrothermal method. In this work, the fluorescence sensor for the detection of heavy and transition metal (HTM) ions has been extensively studied in aqueous solution. The results of the present study indicate that the obtained CA-CdS QDs could detect Cu2+ with high sensitivity and selectivity. It found that the existence of Cu2+ has a significant fluorescence quenching with a large red shifted (from greenish-yellow to yellowish-orange), but not in the presence of 17 other HTM ions. As a result, Cu2S, the energy level below the CdS conduction band, could be formed at the surface of the CA-CdS QDs and leads to the quenching of fluorescence of CA-CdS QDs. Under optimal conditions, the copper ions detection range using the synthesized fluorescence sensor was 1.0 × 10‒8 M to 5.0 × 10‒5 M and the limit of detection (LOD) is 9.2 × 10‒9 M. Besides, the as-synthesized CA-CdS QDs sensor exhibited good selectivity toward Cu2+ relative to other common metal ions. Thus, the CA-CdS QDs has potential applications for detecting Cu2+ in real water samples.


2011 ◽  
Vol 254 ◽  
pp. 13-16
Author(s):  
Badariah Bais ◽  
Liang Wen Loh ◽  
Rosminazuin A. Rahim ◽  
Majlis Burhanuddin Yeop

Micro-cantilever has been proven as an outstanding platform for extremely sensitive chemical and biological sensors. MEMS cantilever-based sensor is becoming popular due to its high sensitivity, high selectivity, easy to fabricate and can be easily integrated with on-chip electronics circuitry. However, the interface circuit used in this kind of sensors typically has a very low resolution and this limits its capability in sensing the small signal generated by the micro-cantilever. One solution is by incorporating stress concentration regions (SCR) on the micro-cantilever which were found to improve the sensitivity of the sensor. This project will focus on optimizing the sensitivity of the micro-cantilever by modeling the micro-cantilever with the SCR technique. The model is then be verified by numerical simulations.


Sign in / Sign up

Export Citation Format

Share Document