Engineering dithiobenzoic acid lactone-decorated Si-rhodamine as a highly selective near-infrared HOCl fluorescent probe for imaging drug-induced acute nephrotoxicity

2019 ◽  
Vol 55 (73) ◽  
pp. 10916-10919 ◽  
Author(s):  
Jinping Wang ◽  
Dan Cheng ◽  
Longmin Zhu ◽  
Peng Wang ◽  
Hong-Wen Liu ◽  
...  

A NIR fluorescent probe based on Si-rhodamine dithiobenzoic acid lactone was used to selectively visualize HOCl during GEN-induced nephrotoxicity for the first time.

2017 ◽  
Vol 8 (5) ◽  
pp. 3479-3483 ◽  
Author(s):  
Xinyuan He ◽  
Lihong Li ◽  
Yu Fang ◽  
Wen Shi ◽  
Xiaohua Li ◽  
...  

The upregulation of leucine aminopeptidase in hepatopathy models is imaged in vivo for the first time with a near-infrared fluorescent probe.


2017 ◽  
Vol 53 (68) ◽  
pp. 9438-9441 ◽  
Author(s):  
Xinyuan He ◽  
Yiming Hu ◽  
Wen Shi ◽  
Xiaohua Li ◽  
Huimin Ma

We have, for the first time, developed a near-infrared fluorescent probe for aminopeptidase N by combining a hemicyanine and an alanyl residue.


2020 ◽  
Vol 1 (4) ◽  
pp. 814-819
Author(s):  
Huan-ren Cheng ◽  
Botao Qu ◽  
Chen Qian ◽  
Meng Xu ◽  
Ruiping Zhang

In this study, for the first time, a novel near-infrared and ratiometric fluorescent probe was conveniently synthesized by reacting PDI-based salicylaldehyde with 2-(hydrazonomethyl)phenol.


2019 ◽  
Vol 55 (95) ◽  
pp. 14307-14310 ◽  
Author(s):  
Wen-Li Jiang ◽  
Yongfei Li ◽  
Wen-Xin Wang ◽  
Yi-Ting Zhao ◽  
Junjie Fei ◽  
...  

A novel hepatocyte-targeting near-infrared ratiometric fluorescent probe named Gal-NIR is developed for detecting ONOO−. The probe can target the hepatocyte and assess drug-induced liver injury and its remediation in living cells and mice.


The Analyst ◽  
2018 ◽  
Vol 143 (20) ◽  
pp. 4860-4869 ◽  
Author(s):  
Ling Zhang ◽  
Xiaoning Kai ◽  
Yiran Zhang ◽  
Youguang Zheng ◽  
Yunsheng Xue ◽  
...  

Endogenously generated selenocysteine in tumor-bearing mice were selectively detected by our reaction-based NIR probe for the first time.


Talanta ◽  
2021 ◽  
Vol 221 ◽  
pp. 121607
Author(s):  
Guo-Jiang Mao ◽  
Guang-Qi Gao ◽  
Wen-Pei Dong ◽  
Qian-Qian Wang ◽  
Ying-Ying Wang ◽  
...  

1991 ◽  
Vol 148 ◽  
pp. 205-206 ◽  
Author(s):  
A. Krabbe ◽  
J. Storey ◽  
V. Rotaciuc ◽  
S. Drapatz ◽  
R. Genzel

Images with subarcsec spatial resolution in the light of near-infrared atomic (Bry) and molecular hydrogen H2 (S(1) v=1-0) emission lines were obtained for some extended, pointlike objects in the Large Magellanic Cloud (LMC) for the first time. We used the Max-Planck-Institut für extraterrestrische Physik (MPE) near-infrared array spectrometer FAST (image scale 0.8”/pix, spectral resolving power 950) at the ESO/MPI 2.2m telescope, La Silla. We present some results on the 30-Dor complex and N159A5.


Sign in / Sign up

Export Citation Format

Share Document