A two-photon active chevron-shaped type I photoinitiator designed for 3D stereolithography

2019 ◽  
Vol 55 (44) ◽  
pp. 6233-6236 ◽  
Author(s):  
Ruchun Zhou ◽  
Jean-Pierre Malval ◽  
Ming Jin ◽  
Arnaud Spangenberg ◽  
Haiyan Pan ◽  
...  

A highly reactive two-photon cleavable initiator with a chevron-shaped architecture has been designed which presents very promising performances for three-dimensional multiphoton fabrication.

2020 ◽  
Vol 11 (1) ◽  
Author(s):  
Jiang Lan Fan ◽  
Jose A. Rivera ◽  
Wei Sun ◽  
John Peterson ◽  
Henry Haeberle ◽  
...  

AbstractUnderstanding the structure and function of vasculature in the brain requires us to monitor distributed hemodynamics at high spatial and temporal resolution in three-dimensional (3D) volumes in vivo. Currently, a volumetric vasculature imaging method with sub-capillary spatial resolution and blood flow-resolving speed is lacking. Here, using two-photon laser scanning microscopy (TPLSM) with an axially extended Bessel focus, we capture volumetric hemodynamics in the awake mouse brain at a spatiotemporal resolution sufficient for measuring capillary size and blood flow. With Bessel TPLSM, the fluorescence signal of a vessel becomes proportional to its size, which enables convenient intensity-based analysis of vessel dilation and constriction dynamics in large volumes. We observe entrainment of vasodilation and vasoconstriction with pupil diameter and measure 3D blood flow at 99 volumes/second. Demonstrating high-throughput monitoring of hemodynamics in the awake brain, we expect Bessel TPLSM to make broad impacts on neurovasculature research.


1997 ◽  
Vol 3 (S2) ◽  
pp. 305-306
Author(s):  
David W. Piston

Two-photon excitation microscopy (TPEM) provides attractive advantages over confocal microscopy for three-dimensionally resolved fluorescence imaging and photochemistry. It provides three-dimensional resolution and eliminates background equivalent to an ideal confocal microscope without requiring a confocal spatial filter, whose absence enhances fluorescence collection efficiency. This results in inherent submicron optical sectioning by excitation alone. In practice, TPEM is made possible by the very high local instantaneous intensity provided by a combination of diffraction-limited focusing of a single laser beam in the microscope and the temporal concentration of 100 femtosecond pulses generated by a mode-locked laser. Resultant peak excitation intensities are 106 times greater than the CW intensities used in confocal microscopy, but the pulse duty cycle of 10−5 limits the average input power to less than 10 mW, only slightly greater than the power normally used in confocal microscopy. Because of the intensity-squared dependence of the two-photon absorption, the excitation is limited to the focal volume.


Author(s):  
Yunpeng Gu ◽  
Ning Kang ◽  
Qianwen Lv ◽  
Yue Qi ◽  
Zhenjun Liu ◽  
...  

Abstract Background Upper arm liposuction mainly focuses on the posterolateral region, which may lead to a lack of harmony between the aspirated and unaspirated areas. In addition, the treatment effect of arm liposuction is often evaluated only by preoperative and postoperative photograph comparison and simple measurement; quantitative research on this topic is still lacking. Methods The multi-positional circumferential arm liposuction (MCAL) technique was proposed and applied to a total of 34 females in our hospital from 2017 to 2019. Three-dimensional data of 12 patients before the operation and after 2–3 months were collected and processed by 3D imaging, and the volume reduction rate was evaluated quantitatively. Results The MCAL method was successfully applied in the clinic, and its surgical effect was quantitatively studied. The mean follow-up time of 12 patients was (75.2 ±13.1) days, and the postoperative volume was significantly reduced. The postoperative volume of patients with type I, type II and type III decreased by (10.79 ±2.55)%, (17.25 ±3.02)% and (22.76 ±3.51)%, respectively. Conclusion Our new MCAL technique was successful, maximizing the esthetic results in upper limb contour refinements in the superficial fascial layer. The clinical efficacy of this proposed MCAL method was evaluated by CT and 3D digital technology, which provided further accuracy in demonstrating its effect on the shape of the arm. Level of evidence IV This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors https://www.springer.com.


2009 ◽  
Vol 14 (4) ◽  
pp. 044029 ◽  
Author(s):  
Hayden Huang ◽  
Catherine MacGillivray ◽  
Hyuk-Sang Kwon ◽  
Jan Lammerding ◽  
Jeffrey Robbins ◽  
...  
Keyword(s):  

2020 ◽  
Vol 10 (23) ◽  
pp. 8563
Author(s):  
Sangmo Koo

Two-photon polymerization (TPP) based on the femtosecond laser (fs laser) direct writing technique in the realization of high-resolution three-dimensional (3D) shapes is spotlighted as a unique and promising processing technique. It is also interesting that TPP can be applied to various applications in not only optics, chemistry, physics, biomedical engineering, and microfluidics but also micro-robotics systems. Effort has been made to design innovative microscale actuators, and research on how to remotely manipulate actuators is also constantly being conducted. Various manipulation methods have been devised including the magnetic, optical, and acoustic control of microscale actuators, demonstrating the great potential for non-contact and non-invasive control. However, research related to the precise control of microscale actuators is still in the early stages, and in-depth research is needed for the efficient control and diversification of a range of applications. In the future, the combination of the fs laser-based fabrication technique for the precise fabrication of microscale actuators/robots and their manipulation can be established as a next-generation processing method by presenting the possibility of applications to various areas.


1981 ◽  
Vol 1 (10) ◽  
pp. 801-810 ◽  
Author(s):  
Karl A. Piez ◽  
Benes L. Trus

A specific fibril model is presented consisting of bundles of five-stranded microfibrils, which are usually disordered (except axially) but under lateral compression become ordered. The features are as follows (where D = 234 residues or 67 nm): (1) D-staggered collagen molecules 4.5 D long in the helical microfibril have a left-handed supercoil with a pitch of 400–700 residues, but microfibrils need not have helical symmetry. (2) Straight-tilted 0.5-D overlap regions on a near-hexagonal lattice contribute the discrete x-ray diffraction reflections arising from lateral order, while the gap regions remain disordered. (3) The overlap regions are equivalent, but are crystallographically distinguished by systematic displacements from the near-hexagonal lattice. (4) The unit cell is the same as in a recently proposed three-dimensional crystal model, and calculated intensities in the equatorial region of the x-ray diffraction pattern agree with observed values.


2020 ◽  
Vol 9 (1) ◽  
pp. 1118-1136
Author(s):  
Zhenjia Huang ◽  
Gary Chi-Pong Tsui ◽  
Yu Deng ◽  
Chak-Yin Tang

AbstractMicro/nano-fabrication technology via two-photon polymerization (TPP) nanolithography is a powerful and useful manufacturing tool that is capable of generating two dimensional (2D) to three dimensional (3D) arbitrary micro/nano-structures of various materials with a high spatial resolution. This technology has received tremendous interest in cell and tissue engineering and medical microdevices because of its remarkable fabrication capability for sophisticated structures from macro- to nano-scale, which are difficult to be achieved by traditional methods with limited microarchitecture controllability. To fabricate precisely designed 3D micro/nano-structures for biomedical applications via TPP nanolithography, the use of photoinitiators (PIs) and photoresists needs to be considered comprehensively and systematically. In this review, widely used commercially available PIs are first discussed, followed by elucidating synthesis strategies of water-soluble initiators for biomedical applications. In addition to the conventional photoresists, the distinctive properties of customized stimulus-responsive photoresists are discussed. Finally, current limitations and challenges in the material and fabrication aspects and an outlook for future prospects of TPP for biomedical applications based on different biocompatible photosensitive composites are discussed comprehensively. In all, this review provides a basic understanding of TPP technology and important roles of PIs and photoresists for fabricating high-precision stimulus-responsive micro/nano-structures for a wide range of biomedical applications.


2006 ◽  
Vol 532-533 ◽  
pp. 568-571
Author(s):  
Ming Zhou ◽  
Hai Feng Yang ◽  
Li Peng Liu ◽  
Lan Cai

The photo-polymerization induced by Two-Photon Absorption (TPA) is tightly confined in the focus because the efficiency of TPA is proportional to the square of intensity. Three-dimensional (3D) micro-fabrication can be achieved by controlling the movement of the focus. Based on this theory, a system for 3D-micro-fabrication with femtosecond laser is proposed. The system consists of a laser system, a microscope system, a real-time detection system and a 3D-movement system, etc. The precision of micro-machining reaches a level down to 700nm linewidth. The line width was inversely proportional to the fabrication speed, but proportional to laser power and NA. The experiment results were simulated, beam waist of 0.413μm and TPA cross section of 2×10-54cm4s was obtained. While we tried to optimize parameters, we also did some research about its applications. With TPA photo-polymerization by means of our experimental system, 3D photonic crystal of wood-pile structure twelve layers and photonic crystal fiber are manufactured. These results proved that the micro-fabrication system of TPA can not only obtain the resolution down to sub-micron level, but also realize real 3D micro-fabrication.


2009 ◽  
Vol 185 (1) ◽  
pp. 11-19 ◽  
Author(s):  
Farideh Sabeh ◽  
Ryoko Shimizu-Hirota ◽  
Stephen J. Weiss

Tissue invasion during metastasis requires cancer cells to negotiate a stromal environment dominated by cross-linked networks of type I collagen. Although cancer cells are known to use proteinases to sever collagen networks and thus ease their passage through these barriers, migration across extracellular matrices has also been reported to occur by protease-independent mechanisms, whereby cells squeeze through collagen-lined pores by adopting an ameboid phenotype. We investigate these alternate models of motility here and demonstrate that cancer cells have an absolute requirement for the membrane-anchored metalloproteinase MT1-MMP for invasion, and that protease-independent mechanisms of cell migration are only plausible when the collagen network is devoid of the covalent cross-links that characterize normal tissues.


Sign in / Sign up

Export Citation Format

Share Document