A new HPLC method for simultaneous analysis of sterols, tocopherols, tocotrienols, and squalene in olive oil deodorizer distillates using a monolithic column with chemometric techniques

2019 ◽  
Vol 11 (36) ◽  
pp. 4681-4692 ◽  
Author(s):  
İsmail Tarhan ◽  
Hüseyin Kara

Simultaneous determination: sterols, tocopherols, tocotrienols, and squalene in an olive oil deodorizer distillate have been separated using a monolithic column.

2016 ◽  
Vol 8 (5) ◽  
pp. 1170-1180 ◽  
Author(s):  
Fanny Galimany-Rovira ◽  
Pilar Pérez-Lozano ◽  
Josep Ma Suñé-Negre ◽  
Encarna García-Montoya ◽  
Montserrat Miñarro ◽  
...  

Simultaneous analysis with a single HPLC run allows for a much more cost-effective and less time-consuming analysis of skin-whitening cream.


2014 ◽  
Vol 64 (2) ◽  
pp. 187-198 ◽  
Author(s):  
Amer M. Alanazi ◽  
Ali S. Abdelhameed ◽  
Nasr Y. Khalil ◽  
Azmat A. Khan ◽  
Ibrahim A. Darwish

Abstract A simple, sensitive and accurate HPLC method with high throughput has been developed and validated for the simultaneous determination of irbesartan (IRB) and hydrochlorothiazide (HCT) in combined pharmaceutical dosage forms. The proposed method employed, for the first time, a monolithic column in the analysis. Optimal chromatographic separation of the analytes was achieved on Chromolith® Performance RP-18e column using a mobile phase consisting of phosphate buffer (pH 4)/acetonitrile (50:50, V/V) pumped isocratically at a flow rate of 1.0 mL min-1. The eluted analytes were monitored with a UV detector set at 270 nm. Under the optimum chromatographic conditions, linear relationship with a good correlation coefficient (R ≥ 0.9997) was found between the peak area and the corresponding concentrations of both IRB and HCT in the ranges of 10-200 and 1-20 ng mL-1. The limits of detection were 2.34 and 0.03 ng mL-1 for IRB and HCT, respectively. The intra- and inter-assay precisions were satisfactory as the RSD values did not exceed 3 %. The accuracy of the proposed method was > 97 %. The proposed method had high throughput as the analysis involved a simple procedure and a very short run- -time of < 3 min. The results demonstrated that the method is applicable in the quality control of combined pharmaceutical tablets containing IRB and HCT


2012 ◽  
Vol 2 (2) ◽  
pp. 364-367 ◽  
Author(s):  
Saida Naik Dheeravath ◽  
◽  
Kasani Ramadevi ◽  
Zilla Saraswathi ◽  
Dheeravath Maniklal ◽  
...  

Author(s):  
Hina Shamshad ◽  
Ali Sayqal ◽  
Jahan Zeb ◽  
Agha Zeeshan Mirza

Abstract A simple, accurate and precise RP-HPLC method was developed for the simultaneous determination of chloroquine, pyrimethamine and cetirizine hydrochloride concentrations in bulk drug and human serum. The assay was performed using a mobile phase of methanol: water (70:30) at pH of 2.8 ± 0.05 on the Purospher C-18 column with UV detection at 230 nm and rosuvastatin used as an internal standard. The retention times observed for chloroquine, pyrimethamine and cetirizine hydrochloride were 3.5, 2.5 and 5.5 minutes, respectively. The method was found to be specific for the assayed drugs showing a linear response in the concentration range of 1–100 μg mL−1 with coefficients of determination values of (r = 0.999). The method was developed and validated according to ICH guidelines. The method was used to monitor the serum samples and was found to be sensitive for therapeutic purposes, showing the potential to be a useful tool for routine analysis in laboratories.


2005 ◽  
Vol 39 (1-2) ◽  
pp. 305-309 ◽  
Author(s):  
Irinel Badea ◽  
Lelia Lazăr ◽  
Dana Moja ◽  
Daniela Nicolescu ◽  
Aurel Tudose

Sign in / Sign up

Export Citation Format

Share Document