Interplay of Coriolis effect with rheology results in unique blood dynamics on a compact disc

The Analyst ◽  
2019 ◽  
Vol 144 (12) ◽  
pp. 3782-3789 ◽  
Author(s):  
Rahul Agarwal ◽  
Arnab Sarkar ◽  
Suman Chakraborty

We investigate the influence of rotational forces on blood dynamics in a microfluidic device.

2018 ◽  
Vol 34 (3) ◽  
pp. 379-382 ◽  
Author(s):  
Shunsuke FURUTANI ◽  
Keiko NISHIO ◽  
Nahoko NARUISHI ◽  
Yoko AKAZAWA-OGAWA ◽  
Yoshihisa HAGIHARA ◽  
...  

2005 ◽  
Vol 51 (10) ◽  
pp. 1955-1961 ◽  
Author(s):  
Nobuo Honda ◽  
Ulrika Lindberg ◽  
Per Andersson ◽  
Stephan Hoffmann ◽  
Hiroyuki Takei

Abstract Background: We explored the potential of a microfluidic device based on centrifugal force as an immunoassay platform by examining the imprecision of assays carried out with 200 nL of sample. Methods: Biotinylated antibodies against α-fetoprotein (AFP), interleukin-6 (IL-6), and carcinoembryonic antigen [(CEA); 0.1 g/L each in 15 mmol/L phosphate-buffered saline (PBS) containing 0.1 mL/L Tween 20] were attached to a microcolumn packed with streptavidin-coated particles. A 200-nL sample was then allowed to pass through the microcolumn for 240 s, followed by Alexa 647–labeled detection antibody (7.5 mg/L in 15 mmol/L PBS containing 10 g/L bovine serum albumin). The flow rate was controlled by altering the rotational speed. Up to 104 sandwich type immunoassays were completed within 50 min. Results: For AFP, IL-6, and CEA the detection limits were, respectively, 0.15, 1.25, and 1.31 pmol/L. Inter- and intraassay imprecisions (CVs) were <10% and <20%, respectively, for analyte concentrations >5 pmol/L. The CEA antibody had the lowest affinity according to fluorescence image analysis of the microcolumn region. The result was confirmed in a comparative study using BIAcore 3000. Conclusions: Day-to-day (total) imprecision (CV) of immunoassays on the compact disc–shaped device are <20%. Analysis of fluorescence images allows rapid ranking of antibodies according to their affinities.


2003 ◽  
Vol 1 (1) ◽  
pp. 60-69
Author(s):  
Mark Tomita

Compact disc (CD-ROM) computer technology have been around for at least a decade, but health educators have been slow to use this technology for health education purposes. This paper describes the process of CD-ROM production in health education.


2019 ◽  
Vol 139 (7) ◽  
pp. 209-216
Author(s):  
Jiaxu Wu ◽  
Yoshikazu Hirai ◽  
Ken-ichiro Kamei ◽  
Toshiyuki Tsuchiya ◽  
Osamu Tabata

2016 ◽  
Vol 136 (9) ◽  
pp. 384-389
Author(s):  
Kazuya Fujimoto ◽  
Hirofumi Shintaku ◽  
Hidetoshi Kotera ◽  
Ryuji Yokokawa

2003 ◽  
Vol 773 ◽  
Author(s):  
Myung-Il Park ◽  
Jonging Hong ◽  
Dae Sung Yoon ◽  
Chong-Ook Park ◽  
Geunbae Im

AbstractThe large optical detection systems that are typically utilized at present may not be able to reach their full potential as portable analysis tools. Accurate, early, and fast diagnosis for many diseases requires the direct detection of biomolecules such as DNA, proteins, and cells. In this research, a glass microchip with integrated microelectrodes has been fabricated, and the performance of electrochemical impedance detection was investigated for the biomolecules. We have used label-free λ-DNA as a sample biomolecule. By changing the distance between microelectrodes, the significant difference between DW and the TE buffer solution is obtained from the impedance-frequency measurements. In addition, the comparison for the impedance magnitude of DW, the TE buffer, and λ-DNA at the same distance was analyzed.


2002 ◽  
Author(s):  
Min Yue ◽  
Katherine Dunphy ◽  
Jerry Jenkins ◽  
Christopher Dames ◽  
Guanghua Wu ◽  
...  

Diabetes ◽  
2019 ◽  
Vol 68 (Supplement 1) ◽  
pp. 101-LB
Author(s):  
ABHINAV BHUSHAN ◽  
SONALI J. KARNIK

Sign in / Sign up

Export Citation Format

Share Document