scholarly journals Point-of-use robotic sensors for simultaneous pressure detection and chemical analysis

2019 ◽  
Vol 6 (3) ◽  
pp. 604-611 ◽  
Author(s):  
Moran Amit ◽  
Rupesh K. Mishra ◽  
Quyen Hoang ◽  
Aida Martin Galan ◽  
Joseph Wang ◽  
...  

This work combined pressure and chemical sensors on disposable, retrofitting gloves to enable simultaneous tactile sensing and pesticide detection in a point-of-use robotic platform.

2020 ◽  
Vol 2 (7) ◽  
pp. 3033-3049
Author(s):  
Raja Nehru ◽  
Shen-Ming Chen

The development of novel chemical sensors for pesticide detection has found particular application in the area of environmental monitoring.


Lab on a Chip ◽  
2019 ◽  
Vol 19 (7) ◽  
pp. 1287-1295 ◽  
Author(s):  
M. Tweedie ◽  
D. Sun ◽  
B. Ward ◽  
P. D. Maguire

Future ocean profiling of dissolved inorganic carbon and other analytes will require miniaturised chemical analysis systems based on sealed gas membranes between two fluid channels.


2020 ◽  
Vol 67 ◽  
pp. 327-374 ◽  
Author(s):  
Jesse Thomason ◽  
Aishwarya Padmakumar ◽  
Jivko Sinapov ◽  
Nick Walker ◽  
Yuqian Jiang ◽  
...  

In this work, we present methods for using human-robot dialog to improve language understanding for a mobile robot agent. The agent parses natural language to underlying semantic meanings and uses robotic sensors to create multi-modal models of perceptual concepts like red and heavy. The agent can be used for showing navigation routes, delivering objects to people, and relocating objects from one location to another. We use dialog clari_cation questions both to understand commands and to generate additional parsing training data. The agent employs opportunistic active learning to select questions about how words relate to objects, improving its understanding of perceptual concepts. We evaluated this agent on Amazon Mechanical Turk. After training on data induced from conversations, the agent reduced the number of dialog questions it asked while receiving higher usability ratings. Additionally, we demonstrated the agent on a robotic platform, where it learned new perceptual concepts on the y while completing a real-world task.


2014 ◽  
Author(s):  
Donald M. Friedrich ◽  
Charles A. Hulse ◽  
Marc von Gunten ◽  
Eric P. Williamson ◽  
Christopher G. Pederson ◽  
...  

Author(s):  
R. Sinclair ◽  
B.E. Jacobson

INTRODUCTIONThe prospect of performing chemical analysis of thin specimens at any desired level of resolution is particularly appealing to the materials scientist. Commercial TEM-based systems are now available which virtually provide this capability. The purpose of this contribution is to illustrate its application to problems which would have been intractable until recently, pointing out some current limitations.X-RAY ANALYSISIn an attempt to fabricate superconducting materials with high critical currents and temperature, thin Nb3Sn films have been prepared by electron beam vapor deposition [1]. Fine-grain size material is desirable which may be achieved by codeposition with small amounts of Al2O3 . Figure 1 shows the STEM microstructure, with large (∽ 200 Å dia) voids present at the grain boundaries. Higher quality TEM micrographs (e.g. fig. 2) reveal the presence of small voids within the grains which are absent in pure Nb3Sn prepared under identical conditions. The X-ray spectrum from large (∽ lμ dia) or small (∽100 Ǻ dia) areas within the grains indicates only small amounts of A1 (fig.3).


Author(s):  
W.C. de Bruijn ◽  
A.A.W. de Jong ◽  
C.W.J. Sorber

One aspect of enzyme cytochemistry is, whether all macrophage lysosomal hydrolytical enzymes are present in an active form, or are activated upon stimulation. Integrated morphometrical and chemical analysis has been chosen as a tool to illucidate that cytochemical problem. Mouse peritoneal resident macrophages have been used as a model for this complicated integration of morphometrical and element-related data. Only aldehyde-fixed cells were treated with three cytochemical reactions to detect different enzyme activities within one cell (for details see [1,2]). The enzyme-related precipitates anticipated to be differentiated, were:(1).lysosomal barium and sulphur from aryl sulphatase activity,(2).lysosomal cerium and phosphate from acid phosphatase activity and(3).platinum/di-amino-benzidine( D A B) complex from endogenous peroxidase activity.


Author(s):  
M. Vallet-Regí ◽  
M. Parras ◽  
J.M. González-Calbet ◽  
J.C. Grenier

BaFeO3-y compositions (0.35<y<0.50) have been investigated by means of electron diffraction and microscopy to resolve contradictory results from powder X-ray diffraction data.The samples were obtained by annealing BaFeO2.56 for 48 h. in the temperature range from 980°C to 1050°C . Total iron and barium in the samples were determined using chemical analysis and gravimetric methods, respectively.In the BaFeO3-y system, according to the electron diffraction and microscopy results, the nonstoichiometry is accommodated in different ways as a function of the composition (y):In the domain between BaFeO2.5+δBaFeO2.54, compositional variations are accommodated through the formation of microdomains. Fig. la shows the ED pattern of the BaFeO2.52 material along thezone axis. The corresponding electron micrograph is seen in Fig. 1b. Several domains corresponding to the monoclinic BaFeO2.50 phase, intergrow with domains of the orthorhombic phase. According to that, the ED pattern of Fig. 1a, can be interpreted as formed by the superposition of three types of diffraction maxima : Very strong spots corresponding to a cubic perovskite, a set of maxima due to the superposition of three domains of the monoclinic phase along [100]m and a series of maxima corresponding to three domains corresponding to the orthorhombic phase along the [100]o.


VASA ◽  
2015 ◽  
Vol 44 (5) ◽  
pp. 355-362 ◽  
Author(s):  
Marie Urban ◽  
Alban Fouasson-Chailloux ◽  
Isabelle Signolet ◽  
Christophe Colas Ribas ◽  
Mathieu Feuilloy ◽  
...  

Abstract. Summary: Background: We aimed at estimating the agreement between the Medicap® (photo-optical) and Radiometer® (electro-chemical) sensors during exercise transcutaneous oxygen pressure (tcpO2) tests. Our hypothesis was that although absolute starting values (tcpO2rest: mean over 2 minutes) might be different, tcpO2-changes over time and the minimal value of the decrease from rest of oxygen pressure (DROPmin) results at exercise shall be concordant between the two systems. Patients and methods: Forty seven patients with arterial claudication (65 + / - 7 years) performed a treadmill test with 5 probes each of the electro-chemical and photo-optical devices simultaneously, one of each system on the chest, on each buttock and on each calf. Results: Seventeen Medicap® probes disconnected during the tests. tcpO2rest and DROPmin values were higher with Medicap® than with Radiometer®, by 13.7 + / - 17.1 mm Hg and 3.4 + / - 11.7 mm Hg, respectively. Despite the differences in absolute starting values, changes over time were similar between the two systems. The concordance between the two systems was approximately 70 % for classification of test results from DROPmin. Conclusions: Photo-optical sensors are promising alternatives to electro-chemical sensors for exercise oximetry, provided that miniaturisation and weight reduction of the new sensors are possible.