Sustained subconjunctival delivery of cyclosporine A using thermogelling polymers for glaucoma filtration surgery

2017 ◽  
Vol 5 (31) ◽  
pp. 6400-6411 ◽  
Author(s):  
Jianguo Sun ◽  
Xi Liu ◽  
Yuan Lei ◽  
Mingyu Tang ◽  
Zhaoxing Dai ◽  
...  

We successfully developed a subconjunctival delivery system of CsA using an injectable thermogel to inhibit post-surgical scar formation after glaucoma filtration surgery.

2016 ◽  
Vol 57 (7) ◽  
pp. 3381 ◽  
Author(s):  
Ajay Sharma ◽  
Govindaraj Anumanthan ◽  
Marcos Reyes ◽  
Huiyi Chen ◽  
Jacob W. Brubaker ◽  
...  

Drug Delivery ◽  
2019 ◽  
Vol 26 (1) ◽  
pp. 812-819 ◽  
Author(s):  
Feng Zhang ◽  
Ke Liu ◽  
Zheng Pan ◽  
Mengdan Cao ◽  
Dengming Zhou ◽  
...  

2009 ◽  
Vol 50 (11) ◽  
pp. 5217 ◽  
Author(s):  
Zhongqiu Li ◽  
Tine Van Bergen ◽  
Sara Van de Veire ◽  
Isabelle Van de Vel ◽  
Huberte Moreau ◽  
...  

2011 ◽  
Vol 93 (5) ◽  
pp. 689-699 ◽  
Author(s):  
Tine Van Bergen ◽  
Evelien Vandewalle ◽  
Sara Van de Veire ◽  
Mieke Dewerchin ◽  
Jean-Marie Stassen ◽  
...  

2021 ◽  
pp. 112067212110177
Author(s):  
Ayse Gul Kocak Altintas ◽  
Cagri Ilhan

Purpose: To compare the phaco time parameters including ultrasound time (UST), effective phaco time (EPT), and average phaco power (APP) in eyes with pseudoexfoliation glaucoma (PEG) and had or had not glaucoma filtration surgery. Methods: In this retrospective comparative study, Group 1 was constructed with 84 PEG patients who had not operated previously, and Group 2 was constructed with 49 PEG patients who had glaucoma filtration surgery. The mean values of UST, EPT, and APP were compared. The preoperative clinical characteristics and surgical manipulations were also compared. Results: The mean ages and male-to-female ratios of the groups were similar ( p > 0.05, for both). There was no difference in the preoperative clinical characteristics, including biometric values between the groups ( p > 0.05, for all). Some surgical manipulations, including pupillary stretching ( p = 0.004), pupillary membrane peeling ( p = 0.021), iris hook using ( p = 0.041), and capsular tension ring implantation ( p = 0.041), were significantly performed more commonly in Group 2. Although the mean UST and EPT values were similar ( p > 0.05, for both), the mean APP value was significantly lower in Group 2 ( p = 0.011). Conclusion: The lower APP parameter was observed in PEG patients having had glaucoma filtration surgery. Needing more surgical manipulation to overcome poor pupillary dilation and weak zonular instability can be a reason for this result.


Sign in / Sign up

Export Citation Format

Share Document