Nanocrystalline cellulose mediated seed-growth for ultra-robust colorimetric detection of hydrogen sulfide

Nanoscale ◽  
2017 ◽  
Vol 9 (28) ◽  
pp. 9811-9817 ◽  
Author(s):  
Yuexiao Jia ◽  
Yongming Guo ◽  
Shiwen Wang ◽  
Wenwen Chen ◽  
Jiangjiang Zhang ◽  
...  

We describe an ultra-stable, ultra-robust, straightforward and low-cost approach for the colorimetric detection of H2S with nanocrystalline cellulose (NCC) based on the reaction of H2S with lead acetate.

2020 ◽  
Vol 18 (1) ◽  
pp. 303-313 ◽  
Author(s):  
Aamir Rasheed ◽  
Tahseen Ghous ◽  
Sumaira Mumtaz ◽  
Muhammad Nadeem Zafar ◽  
Kalsoom Akhter ◽  
...  

AbstractIn the present work, a novel continuous flow system (CFS) is developed for the preconcentration and determination of Cr (VI) using Pseudomonas aeruginosa static biomass immobilized onto an effective and low-cost solid support of powdered eggshells. A mini glass column packed with the immobilized biosorbent is incorporated in a CFS for the preconcentration and determination of Cr (VI) from aqueous solutions. The method is based on preconcentration, washing and elution steps followed by colorimetric detection with 1,5-diphenyl carbazide in sulphuric acid. The effects of several variables such as pH, retention time, flow rate, eluent concentration and loaded volume are studied. Under optimal conditions, the CFS method has a linear range between 10 and 100 μg L-1 and a detection limit of 6.25 μg L-1 for the determination of Cr (VI). The sampling frequency is 10 samples per hour with a preconcentration time of 5 mins. Furthermore, after washing with a 0.1 M buffer (pH 3.0), the activity of the biosorbent is regenerated and remained comparable for more than 200 cycles. Scanning electron microscopy reveals a successful immobilization of biomass on eggshells powder and precipitation of Cr (VI) on the bacterial cell surface. The proposed method proves highly sensitive and could be suitable for the determination of Cr (VI) at an ultra-trace level.


e-Polymers ◽  
2021 ◽  
Vol 21 (1) ◽  
pp. 500-510
Author(s):  
Xiaoguang Ying ◽  
Jieyuan He ◽  
Xiao Li

Abstract An imprinted electrospun fiber membrane was developed for the detection of volatile organic acids, which are key components of human body odor. In this study, hexanoic acid (HA) was selected as the target, polymethyl methacrylate (PMMA) was used as the substrate, and colorimetric detection of HA was achieved by a bromocresol purple (BCP) chromogenic agent. The results showed that the morphology of the fiber membrane was uniform and continuous, and it showed excellent selectivity and specificity to HA. Photographs of the color changes before and after fiber membrane adsorption were recorded by a camera and quantified by ImageJ software by the difference in gray value (ΔGray). This method is simple, intuitive, and low cost and has great potential for application in human odor analysis.


2004 ◽  
Vol 50 (1) ◽  
pp. 185-191 ◽  
Author(s):  
J.E. Ebdon ◽  
J.L. Wallis ◽  
H.D. Taylor

Antibiotic resistance profiling (ARP) is a potentially useful method for distinguishing faecal bacteria according to host source. This phenotypic approach has cost benefits over genotypic methods, but existing protocols are time-consuming and manual data handling is open to human error. A simplified, low-cost approach to the ARP technique was developed that used automated data recording techniques combined with simple statistical analyses to compare isolates of the genus Enterococcus from various faecal sources. An initial battery of 21 antibiotics (at up to four concentrations) was chosen for source discrimination. Images of growth or non-growth in microplate wells were stored as bitmaps and converted to binary data to form a database of known antibiotic resistance profiles. Discriminant function analysis (DFA) showed that the average rate of isolates correctly classified by the database (wastewater vs non-wastewater) was 86%. Once the more discriminating antibiotics and their concentrations had been identified, it was possible to reduce the number of tests from 80 to 18 whilst increasing the number of correctly classified human isolates. ARP could offer a low-cost and rapid means of identifying sources of faecal pollution. As such, the technique may be of particular benefit to developing countries, where water quality may have a significant impact on health and where cost is a major factor when choosing environmental management technology.


2019 ◽  
Vol 4 (3) ◽  
pp. 580-585 ◽  
Author(s):  
Bineh G. Ndefru ◽  
Bryan S. Ringstrand ◽  
Sokhna I.-Y. Diouf ◽  
Sönke Seifert ◽  
Juan H. Leal ◽  
...  

Combining bottom-up self-assembly with top-down 3D photoprinting affords a low cost approach for the introduction of nanoscale features into a build with low resolution features.


The Analyst ◽  
2015 ◽  
Vol 140 (4) ◽  
pp. 1260-1264 ◽  
Author(s):  
Yanhong Zhu ◽  
Guangfeng Wang ◽  
Liang Sha ◽  
Yuwei Qiu ◽  
Hong Jiang ◽  
...  

Development of strategies for the sensitive and selective detection of the folate receptor (FR) that are simple and low cost is of great importance for assessing cancer therapeutics due to its crucial role in physiological, pharmacological and pathological processes.


2011 ◽  
Vol 59 (4) ◽  
pp. 1155-1163 ◽  
Author(s):  
Mohamed H. Awida ◽  
Shady H. Suleiman ◽  
Aly E. Fathy

Sign in / Sign up

Export Citation Format

Share Document