Sensitive and selective detection of nitrite ions with highly fluorescent glutathione-stabilized copper nanoclusters

2017 ◽  
Vol 9 (38) ◽  
pp. 5668-5673 ◽  
Author(s):  
Dan-Ling Zhou ◽  
Hong Huang ◽  
Yan Wang

Highly fluorescent glutathione stabilized Cu NCs were simply prepared in a one-pot manner. The Cu NCs can be applied as a robust probe for the determination of NO2− in real water samples with high sensitivity and good recoveries.

2019 ◽  
Vol 11 (40) ◽  
pp. 5214-5221 ◽  
Author(s):  
Mingyu Tang ◽  
Xiaodong Liu ◽  
Nannan Zhang ◽  
Jingyu Pang ◽  
Yu Zou ◽  
...  

Herein, nitrogen and sulfur codoped carbon dots (N&S CDs) were prepared by hydrothermal process and could be introduced as a fluorescent probe for determination of Cd2+, yielding high sensitivity and excellent selectivity.


2012 ◽  
Vol 179 (3-4) ◽  
pp. 193-199 ◽  
Author(s):  
Sha Peng ◽  
Jing Xiao ◽  
Jing Cheng ◽  
Miao Zhang ◽  
Xiaoyan Li ◽  
...  

2020 ◽  
Vol 44 (16) ◽  
pp. 6232-6237 ◽  
Author(s):  
Lei Shi ◽  
Huijuan Yu ◽  
Xianqing Zeng ◽  
Sheng Yang ◽  
Shengzhao Gong ◽  
...  

A novel ratiometric fluorescent probe based on thieno[3,2-c]coumarin has been prepared for sensing hypochlorite, which could exhibit a large emission shift and a 338-fold emission ratio (I470/I640).


2017 ◽  
Vol 164 (9) ◽  
pp. B463-B469 ◽  
Author(s):  
Mani Govindasamy ◽  
Sakthivel Kogularasu ◽  
Shen-Ming Chen ◽  
Yi-Hui Cheng ◽  
Muthumariappan Akilarasan ◽  
...  

2014 ◽  
Vol 70 (7) ◽  
pp. 1182-1187 ◽  
Author(s):  
Zhe Chen ◽  
Hua Li

Based on the sensitive reaction of Co(II) and salicyl fluorone with the presence of cetylpyridinium bromide in basic solution, a new method of flow injection micelle-solubilized spectrophotometry was developed for the determination of cobalt. The reaction was monitored for the absorbance of Co(II) at 540 nm. The reagents, flow injection variables and effects of foreign ions were investigated and the optimum conditions were established. At the optimum test conditions, the developed method provides a linearity range of 3–40 μg L−1 with a detection limit of 0.1 μg L−1 at about 60 h−1 sampling frequency. Relative standard deviation of 0.91, 0.95 and 0.89% were obtained for the determination of 3, 15 and 30 μg L−1 Co(II) solution. The proposed method has been successfully applied for analysis of trace amounts of cobalt in water samples.


The Analyst ◽  
2016 ◽  
Vol 141 (19) ◽  
pp. 5555-5562 ◽  
Author(s):  
Lili Xiao ◽  
Jiao Yin ◽  
Yingchun Li ◽  
Qunhui Yuan ◽  
Hangjia Shen ◽  
...  

A high sensitivity sensor for detection of hydroquinone and catechol was constructed based on nitrogen and sulfur co-doped activated graphene.


Sign in / Sign up

Export Citation Format

Share Document