Maghemite-human serum albumin hybrid nanoparticles: towards a theranostic system with high MRI r2* relaxivity

2016 ◽  
Vol 4 (21) ◽  
pp. 3801-3814 ◽  
Author(s):  
Rivka Ben Ishay ◽  
Liron L. Israel ◽  
Esthy Levy Eitan ◽  
David M. Partouche ◽  
Jean-Paul Lellouche

Magnetic hybrid human serum albumin-based NPs were successfully fabricated, disclosing a powerful T2* contrast agent for dual therapeutic and diagnostic applications.

2018 ◽  
Vol 54 (82) ◽  
pp. 11586-11589
Author(s):  
Jeong Yu Lee ◽  
Ho Yeon Son ◽  
Jae Chul Park ◽  
Jongnam Park ◽  
Yoon Sung Nam

Self-assembly of monodisperse superparamagnetic iron oxide nanocrystals into a close-packed, three-dimensional (3D) superlattice is designed within cross-linked protein-based nanoparticles composed of human serum albumin and polyethylene glycol.


2019 ◽  
Vol 2 (2) ◽  
pp. 279-302 ◽  
Author(s):  
Subhadeep Banerjee ◽  
Jayeeta Sengupta ◽  
Ana Isabel Aljarilla ◽  
Francesca Setaro ◽  
Petri Makinen ◽  
...  

Diseases caused by obstruction or rupture of vulnerable plaques in the arterial walls such as cardiovascular infarction or stroke are the leading cause of death in the world. In the present work, we developed human serum albumin nanoparticles loaded by physisorption with zinc phthalocyanine, TT1, mainly used for industrial application as near-infrared photosensitizer and compared these to HSA NPs loaded with the well-known silicone phthalocyanine (Pc4). The use of NIR light allows for better tissue penetration, while the use of nanoparticles permits high local concentrations. The particles were characterized and tested for toxicity and stability as well as for their potential use as a contrast agent and NIR photosensitizer for photodynamic therapy in cardiovascular disease. We focused on the distribution of the nanoparticles in RAW264.7 macrophage cells and atherosclerotic mice. The nanoparticles had an average size of 120 nm according to dynamic light scattering, good loading capacity for zinc phthalocyanine, and satisfying stability in 50% (v/v) fetal bovine serum for 8 hours and in an aqueous environment at 4°C for 4–6 weeks. Under light irradiation we found a high production of singlet oxygen and the products showed no dark toxicity in vitro with macrophages (the target cells in vulnerable plaques), but at a low g/mL nanoparticle concentration killed efficiently the macrophages upon LED illumination. Injection of the contrast agent in atherosclerotic mice led to a visible fluorescence signal of zinc phthalocyanine in the atherosclerotic plaque at 30 minutes and in the lungs with a fast clearance of the nanoparticles. Zinc phthalocyanine loaded human serum albumin nanoparticles present an interesting candidate for the visualization and potentially photodynamic treatment of macrophages in atherosclerotic plaques.


Author(s):  
Louise R Tear ◽  
Carla Carrera ◽  
Chetan Bharatkumar Dhakan ◽  
Eleonora Cavallari ◽  
Fabio Travagin ◽  
...  

Gadolinium contrast agents that bind to human serum albumin (HSA) can achieve significantly higher relaxivity values and show improved vascular retention time. Most contrast agents of this design are linear...


1969 ◽  
Vol 08 (01) ◽  
pp. 15-21 ◽  
Author(s):  
K. E. Scheer ◽  
J. Heep ◽  
W. Maier-Borst ◽  
W. J. Lorenz ◽  
H. Sinn ◽  
...  

ZusammenfassungNach tierexperimentellen Voruntersuchungen wurde die Placentographie mit trägerfreiem 113Inm -HSA als klinische Methode eingeführt. Vor Amniocentesen und bei Verdacht auf Placenta praevia werden Placentographien geschrieben. Den Schwangeren wird eine Aktivität von 500 μCi in die Cubitalvene injiziert. Die der Aktivität entsprechende Indiummenge ist kleiner als 0,1 ng. Die fetale Strahlenbelastung liegt unter lOmrad. Bei Anwendung von 113Inm-HSA entfällt eine Blockade der mütterlichen und fetalen Schilddrüsen. Die genaue Abgrenzung einer Placenta praevia wird nicht durch eine Blasenaktivität beeinträchtigt.Es wurden bisher 19 Placentalokalisationen durchgeführt. In allen Fällen konnte der Placentasitz eindeutig festgestellt werden. Bedingt durch die lange Liegezeit beim Aufnehmen eines Szintigramms kam es in zwei Fällen zu einem Vena-Cava-Kompressions-Syndrom. Zur Verhinderung dieser klinischen Zwischenfälle werden inzwischen Placentographien mit der Anger-Kamera aufgenommen. Mit Hilfe des divergierenden Kollimators konnte der gesamte Abdominalbereich erfaßt werden. Die Aufnahmezeit konnte auf 7 — 10 Minuten verkürzt werden. Die intravenöse injizierte Aktivität betrug bei dieser Methode ebenfalls 500 μCi. Der diagnostische Aussagewert der Kamerabilder ist szintigraphischen Aufnahmen gleichwertig.


Sign in / Sign up

Export Citation Format

Share Document