Highly selective fluorescence detection of Pd2+/4+ species based on a catalyzed aromatic Claisen rearrangement

RSC Advances ◽  
2015 ◽  
Vol 5 (128) ◽  
pp. 105810-105813 ◽  
Author(s):  
Xuejing Li ◽  
Huanhuan Huang ◽  
Yuqing Zhu ◽  
Hong Zhao ◽  
Zhifei Wang

A highly selective chemodosimeter based on 1,8-naphthalimide for Pd2+/4+ species via a Claisen rearrangement was developed with a detection limit of 1.4 μM.

2020 ◽  
Vol 16 ◽  
Author(s):  
Ikko Mikami ◽  
Eri Shibayama ◽  
Kengo Takagi

Background: Determination of a reducing substance based on the reaction between Ce(IV) and a reducing substance and fluorescence detection of Ce(III) generated has been reported as a selective and sensitive method. However, this method could not be applied to the determination of alcohol due to the low reaction rate of alcohol and Ce(IV). Objective: We found that thiosulfate catalytically enhanced reaction of alcohols (such as, methanol, ethanol, and propanol) and Ce(IV). Utilizing this effect, we developed a new method for the determination of alcohols. Results: In the presence of thiosulfate, an increase in fluorescence intensity was detected by injecting alcohol at concentrations of several millimolar, whereas it was not observed even at the concentration of 10% v/v (2 M for ethanol) in the absence of thiosulfate. The optimum detection conditions were determined to be 4.0 mM Ce(IV) sulfate and 0.50 mM thiosulfate, and the detection limit (S/N = 3) of ethanol under these conditions was 1 mM. In the calibration curves, changes in the slope were observed when the alcohol concentrations were approximately 10–25 mM. Using a thiosulfate solution containing ethanol as the reaction solution, a calibration curve without any change in slope was obtained, although the concentration of ethanol at the detection limit increased. The alcohols in the liquor and fuel were successfully analyzed using the proposed detection method as a postcolumn reaction. Conclusion: This new alcohol detection method using a versatile fluorescence detector can be applied to the postcolumn reaction of HPLC omitting need of time-consuming pretreatment processes.


The Analyst ◽  
2014 ◽  
Vol 139 (9) ◽  
pp. 2114-2117 ◽  
Author(s):  
Xiulan He ◽  
Li Zhang ◽  
Hetong Qi ◽  
Ping Yu ◽  
Junjie Fei ◽  
...  

We have demonstrated a new strategy to improve the fluorescence detection limit by enhancing the energy transfer efficiency between carbon structures and fluorescent dyes using polyimidazolium-functionalized carbon nanostructures as a low background signal platform.


2005 ◽  
Vol 46 (14) ◽  
pp. 2457-2460 ◽  
Author(s):  
James R. Vyvyan ◽  
Jennifer M. Oaksmith ◽  
Bevin W. Parks ◽  
Elaine M. Peterson

1987 ◽  
Vol 70 (5) ◽  
pp. 813-818 ◽  
Author(s):  
T Bill Waggoner ◽  
Malcolm C Bowman

Abstract A spectrofluorometric (SPF) method is described for determination of residues of BAY Vp 2674 in chicken and turkey tissues. The drug is extracted from tissues with dichloromethane-methanol. The organic extract is concentrated to near dryness and cleaned up by a series of partitionings with n-hexane, then dichloromethane against pH 2 buffer and dichloromethane against pH 12 buffer. The drug is partitioned into dichloromethane from pH 7 buffer and concentrated to dryness. The residue is dissolved in pH 3.5 buffer for SPF analysis at 282 nm (excitation) and 445 nm (emission). Recoveries of BAY Vp 2674 added to chicken and turkey tissues at levels of 0.05, 0.1, and 0.2 ppm range from 86 to 92% with a coefficient of variation of 3.4-10.1%. Detection limit is 0.02 ppm. A liquid chromatographic confirmatory procedure is also described, with ultraviolet and fluorescence detection


2020 ◽  
Vol 13 (5) ◽  
pp. 2425-2439 ◽  
Author(s):  
Andrew W. Rollins ◽  
Pamela S. Rickly ◽  
Ru-Shan Gao ◽  
Thomas B. Ryerson ◽  
Steven S. Brown ◽  
...  

Abstract. We describe a newly developed single-photon laser-induced fluorescence sensor for measurements of nitric oxide (NO) in the atmosphere. Rapid tuning of a narrow-band laser on and off of a rotationally resolved NO spectral feature near 215 nm and detection of the red-shifted fluorescence provides for interference-free direct measurements of NO with a detection limit of 1 part per trillion by volume (pptv) for 1 s of integration, or 0.3 pptv for 10 s of integration. Uncertainty in the sensitivity of the instrument is typically ±6–9 %, with no known interferences. Uncertainty in the zero of the detector is shown to be <0.2 pptv. The instrument was deployed on the NASA DC-8 aircraft during the NASA/NOAA FIREX-AQ experiment (Fire Influence on Regional to Global Environments Experiment – Air Quality) during July–September 2019 and provided more than 140 h of NO measurements over 22 flights, demonstrating the ability of this instrument to operate routinely and autonomously. Comparisons with a seasoned chemiluminescence sensor during FIREX-AQ in a variety of chemical environments provides validation and confidence in the accuracy of this technique.


2014 ◽  
Vol 136 (10) ◽  
pp. 3817-3827 ◽  
Author(s):  
Matthew F. L. Parker ◽  
Sílvia Osuna ◽  
Guillaume Bollot ◽  
Shivaiah Vaddypally ◽  
Michael J. Zdilla ◽  
...  

2014 ◽  
Vol 989-994 ◽  
pp. 2761-2763
Author(s):  
Yong Qiang Cheng ◽  
Cui Lian Guo ◽  
Bin Zhao ◽  
Li Yang

Laser induced fluorescence (LIF) detection technique is one of the most sensitive detection method in micro total analytical systems (μTAS) as its good monochromaticity, strong collimation and high optical density. It is widely used in biochemical analysis systems and the detection limit could reach 10-9-10-12mol/L. Due to the important role in μTAS, different optical structure arrangements of LIF detection techniques were continuously developed. We reviewed the recent progress of the optical structure arrangement and the applications of the LIF detection techniques.


Sign in / Sign up

Export Citation Format

Share Document