Simultaneous determination of whitening agents and parabens in cosmetic products by capillary electrophoresis with on-line sweeping enhancement

2014 ◽  
Vol 6 (19) ◽  
pp. 7615-7620 ◽  
Author(s):  
I-Chi Tsai ◽  
Chia-Yu Su ◽  
Cho-Chun Hu ◽  
Tai-Chia Chiu

An on-line sweeping-MEKC method for simultaneous determination of whitening agents and parabens in commercial cosmetic products was demonstrated. This approach was shown to offer high separation efficiency, short analysis time, and convenience of analysis. The LODs of the analytes were in the range from 8 to 162 nM (1.1 to 21.0 ng mL−1) and a 46 to 279-fold enhancement was achieved.

1996 ◽  
Vol 42 (11) ◽  
pp. 1805-1811 ◽  
Author(s):  
C X Zhang ◽  
Y Aebi ◽  
W Thormann

Abstract Binary-system capillary electrophoresis (CE) with head-column field-amplified sample stacking permits determination of amiodarone and desethylamiodarone in 20-microL serum samples. The assay is characterized by a detection limit for both compounds of 80 nmol/L and by excellent linear response over the recommended therapeutic range for amiodarone (1.5-4 mumol/L). Intra- and interday reproducibilities (CVs) between 3% and 6% and run times of approximately 10 min are comparable with those for conventional HPLC. Besides excellent sensitivity, attractive features of the assay include low operating costs, high separation efficiency, rapid drug extraction, consumption of almost negligible amounts of organic solvents, and simple operation. If appropriate microvessels and liquid-handling facilities are available, the same assay can be performed with 2 microL of serum, and if the serum is not diluted but rather is concentrated during extraction, < 1 nmol/L of amiodarone can be detected.


Talanta ◽  
2020 ◽  
Vol 209 ◽  
pp. 120578
Author(s):  
Xiaoyu Song ◽  
Rui Zhang ◽  
Yue Wang ◽  
Mengqing Feng ◽  
Honghua Zhang ◽  
...  

Molecules ◽  
2021 ◽  
Vol 26 (4) ◽  
pp. 993
Author(s):  
Błażej Grodner ◽  
Mariola Napiórkowska

In this study, a complex consisting of 2-hydroxypropyl-β-cyclodextrin and 5,10,15,20-tetrakis (4-hydroxyphenyl) porphyrin, (named dual chiral-achiral selector complex) was used for the determination of two novel potential anticancer agents of (I) and (II) aminoalkanol derivatives. This work aimed at developing an effective method that can be utilized for the determination of I (S), I (R), and II (S) and II (R) enantiomers of (I) and (II) compounds through the use of a dual chiral-achiral selector complex consisting of hydroxypropyl-β-cyclodextrin and 5,10,15,20-tetrakis (4-hydroxyphenyl) porphyrin system by applying capillary electrophoresis. This combination proved to be beneficial in achieving high separation selectivity due to the combined effects of different modes of chiral discrimination. The enantiomers of (I) and (II) compounds were separated within a very short time of 3.6–7.2 min, in pH 2.5 phosphate buffer containing 2-hydroxypropyl-β-cyclodextrin and 5,10,15,20-tetrakis (4-hydroxyphenyl) porphyrin system at a concentration of 5 and 10 mM, respectively, at 25 °C and +10 kV. The detection wavelength of the detector was set at 200 nm. The LOD for I (S), I (R), II (S), and II (R) was 65.2, 65.6, 65.1, and 65.7 ng/mL, respectively. LOQ for I (S), I (R), II (S), and II (R) was 216.5, 217.8, 217.1, and 218.1 ng/mL, respectively. Recovery was 94.9–99.9%. The repeatability and reproducibility of the method based on the values of the migration time, and the area under the peak was 0.3–2.9% RSD. The stability of the method was determined at 0.1–4.9% RSD. The developed method was used in the pilot studies for determining the enantiomers I (S), I (R), II (S), and II (R) in the blood serum.


Sign in / Sign up

Export Citation Format