Site location optimization of regional air quality monitoring network in china: methodology and case study

2011 ◽  
Vol 13 (11) ◽  
pp. 3185 ◽  
Author(s):  
Junyu Zheng ◽  
Xiaoqiong Feng ◽  
Panwei Liu ◽  
Liuju Zhong ◽  
Senchao Lai
2011 ◽  
Vol 6 (3) ◽  
pp. 63-72 ◽  
Author(s):  
Jarmila Rimbalová ◽  
Silvia Vilčeková ◽  
Adriana Eštoková

2021 ◽  
Vol 13 (15) ◽  
pp. 8263
Author(s):  
Marius Bodor

An important aspect of air pollution analysis consists of the varied presence of particulate matter in analyzed air samples. In this respect, the present work aims to present a case study regarding the evolution in time of quantified particulate matter of different sizes. This study is based on data acquisitioned in an indoor location, already used in a former particulate matter-related article; thus, it can be considered as a continuation of that study, with the general aim to demonstrate the necessity to expand the existing network for pollution monitoring. Besides particle matter quantification, a correlation of the obtained results is also presented against meteorological data acquisitioned by the National Air Quality Monitoring Network. The transformation of quantified PM data in mass per volume and a comparison with other results are also addressed.


2018 ◽  
Vol 5 (9) ◽  
pp. 180889 ◽  
Author(s):  
Zhengqiu Zhu ◽  
Bin Chen ◽  
Sihang Qiu ◽  
Rongxiao Wang ◽  
Yiping Wang ◽  
...  

The chemical industry is of paramount importance to the world economy and this industrial sector represents a substantial income source for developing countries. However, the chemical plants producing inside an industrial district pose a great threat to the surrounding atmospheric environment and human health. Therefore, designing an appropriate and available air quality monitoring network (AQMN) is essential for assessing the effectiveness of deployed pollution-controlling strategies and facilities. As monitoring facilities located at inappropriate sites would affect data validity, a two-stage data-driven approach constituted of a spatio-temporal technique (i.e. Bayesian maximum entropy) and a multi-objective optimization model (i.e. maximum concentration detection capability and maximum dosage detection capability) is proposed in this paper. The approach aims at optimizing the design of an AQMN formed by gas sensor modules. Owing to the lack of long-term measurement data, our developed atmospheric dispersion simulation system was employed to generate simulated data for the above method. Finally, an illustrative case study was implemented to illustrate the feasibility of the proposed approach, and results imply that this work is able to design an appropriate AQMN with acceptable accuracy and efficiency.


2021 ◽  
Author(s):  
Sonu Kumar Jha ◽  
Mohit Kumar ◽  
Vipul Arora ◽  
Sachchida Nand Tripathi ◽  
Vidyanand Motiram Motghare ◽  
...  

<div>Air pollution is a severe problem growing over time. A dense air-quality monitoring network is needed to update the people regarding the air pollution status in cities. A low-cost sensor device (LCSD) based dense air-quality monitoring network is more viable than continuous ambient air quality monitoring stations (CAAQMS). An in-field calibration approach is needed to improve agreements of the LCSDs to CAAQMS. The present work aims to propose a calibration method for PM2.5 using domain adaptation technique to reduce the collocation duration of LCSDs and CAAQMS. A novel calibration approach is proposed in this work for the measured PM2.5 levels of LCSDs. The dataset used for the experimentation consists of PM2.5 values and other parameters (PM10, temperature, and humidity) at hourly duration over a period of three months data. We propose new features, by combining PM2.5, PM10, temperature, and humidity, that significantly improved the performance of calibration. Further, the calibration model is adapted to the target location for a new LCSD with a collocation time of two days. The proposed model shows high correlation coefficient values (R2) and significantly low mean absolute percentage error (MAPE) than that of other baseline models. Thus, the proposed model helps in reducing the collocation time while maintaining high calibration performance.</div>


2018 ◽  
Vol 137 ◽  
pp. 11-17 ◽  
Author(s):  
Hong-di He ◽  
Min Li ◽  
Wei-li Wang ◽  
Zhan-yong Wang ◽  
Yu Xue

Sign in / Sign up

Export Citation Format

Share Document