scholarly journals Applications Of Microspectroscopy, Hyperspectral Chemical Imaging And Fluorescence Microscopy In Chemistry, Biochemistry, Biotechnology, Molecular And Cell Biology

2011 ◽  
Author(s):  
I. Baianu
Author(s):  
K. Jacobson ◽  
A. Ishihara ◽  
B. Holifield ◽  
F. Zhang

Our laboratory is concerned with understanding the dynamic structure of the plasma membrane with particular reference to the movement of membrane constituents during cell locomotion. In addition to the standard tools of molecular cell biology, we employ both fluorescence recovery after photo- bleaching (FRAP) and digitized fluorescence microscopy (DFM) to investigate individual cells. FRAP allows the measurement of translational mobility of membrane and cytoplasmic molecules in small regions of single, living cells. DFM is really a new form of light microscopy in that the distribution of individual classes of ions, molecules, and macromolecules can be followed in single, living cells. By employing fluorescent antibodies to defined antigens or fluorescent analogs of cellular constituents as well as ultrasensitive, electronic image detectors and video image averaging to improve signal to noise, fluorescent images of living cells can be acquired over an extended period without significant fading and loss of cell viability.


2018 ◽  
Vol 29 (6) ◽  
pp. 763-771 ◽  
Author(s):  
Robert D. Phair

Genetically encoded fluorescent proteins, combined with fluorescence microscopy, are widely used in cell biology to collect kinetic data on intracellular trafficking. Methods for extraction of quantitative information from these data are based on the mathematics of diffusion and tracer kinetics. Current methods, although useful and powerful, depend on the assumption that the cellular system being studied is in a steady state, that is, the assumption that all the molecular concentrations and fluxes are constant for the duration of the experiment. Here, we derive new tracer kinetic analytical methods for non–steady state biological systems by constructing mechanistic nonlinear differential equation models of the underlying cell biological processes and linking them to a separate set of differential equations governing the kinetics of the fluorescent tracer. Linking the two sets of equations is based on a new application of the fundamental tracer principle of indistinguishability and, unlike current methods, supports correct dependence of tracer kinetics on cellular dynamics. This approach thus provides a general mathematical framework for applications of GFP fluorescence microscopy (including photobleaching [FRAP, FLIP] and photoactivation to frequently encountered experimental protocols involving physiological or pharmacological perturbations (e.g., growth factors, neurotransmitters, acute knockouts, inhibitors, hormones, cytokines, and metabolites) that initiate mechanistically informative intracellular transients. When a new steady state is achieved, these methods automatically reduce to classical steady state tracer kinetic analysis.


2019 ◽  
Vol 70 (1) ◽  
pp. 199-218
Author(s):  
Joshua D. Morris ◽  
Christine K. Payne

Understanding the cellular basis of human health and disease requires the spatial resolution of microscopy and the molecular-level details provided by spectroscopy. This review highlights imaging methods at the intersection of microscopy and spectroscopy with applications in cell biology. Imaging methods are divided into three broad categories: fluorescence microscopy, label-free approaches, and imaging tools that can be applied to multiple imaging modalities. Just as these imaging methods allow researchers to address new biological questions, progress in biological sciences will drive the development of new imaging methods. We highlight four topics in cell biology that illustrate the need for new imaging tools: nanoparticle-cell interactions, intracellular redox chemistry, neuroscience, and the increasing use of spheroids and organoids. Overall, our goal is to provide a brief overview of individual imaging methods and highlight recent advances in the use of microscopy for cell biology.


2004 ◽  
Vol 12 (1) ◽  
pp. 3-7
Author(s):  
Stephen W. Carmichael ◽  
Jon Charlesworth

The use of fluorescent probes is becoming more and more common in cell biology. It would be useful if we were able to correlate a fluorescent structure with an electron microscopic image. The ability to definitively identify a fluorescent organelle would be very valuable. Recently, Ying Ren, Michael Kruhlak, and David Bazett-Jones devised a clever technique to correlate a structure visualized in the light microscope, even a fluorescing cell, with transmission electron microscopy (TEM).Two keys to the technique of Ren et al are the use of grids (as used in the TEM) with widely spaced grid bars and the use of Quetol as the embedding resin. The grids allow for cells to be identified between the grid bars, and in turn the bars are used to keep the cell of interest in register throughout the processing for TEM. Quetol resin was used for embedding because of its low auto fluorescence and sectioning properties. The resin also becomes soft and can be cut and easily peeled from glass coverslips when heated to 70°C.


2009 ◽  
Vol 185 (7) ◽  
pp. 1135-1148 ◽  
Author(s):  
Jennifer C. Waters

The light microscope has long been used to document the localization of fluorescent molecules in cell biology research. With advances in digital cameras and the discovery and development of genetically encoded fluorophores, there has been a huge increase in the use of fluorescence microscopy to quantify spatial and temporal measurements of fluorescent molecules in biological specimens. Whether simply comparing the relative intensities of two fluorescent specimens, or using advanced techniques like Förster resonance energy transfer (FRET) or fluorescence recovery after photobleaching (FRAP), quantitation of fluorescence requires a thorough understanding of the limitations of and proper use of the different components of the imaging system. Here, I focus on the parameters of digital image acquisition that affect the accuracy and precision of quantitative fluorescence microscopy measurements.


2016 ◽  
Vol 22 (5) ◽  
pp. 1062-1071 ◽  
Author(s):  
Lorella Pascolo ◽  
Alessandra Gianoncelli ◽  
Clara Rizzardi ◽  
Martin de Jonge ◽  
Daryl Howard ◽  
...  

AbstractAsbestos bodies are the histological hallmarks of asbestos exposure. Both conventional and advanced techniques are used to evaluate abundance and composition in histological samples. We previously reported the possibility of using synchrotron X-ray fluorescence microscopy (XFM) for analyzing the chemical composition of asbestos bodies directly in lung tissue samples. Here we applied a high-performance synchrotron X-ray fluorescence (XRF) set-up that could allow new protocols for fast monitoring of the occurrence of asbestos bodies in large histological sections, improving investigation of the related chemical changes. A combination of synchrotron X-ray transmission and fluorescence microscopy techniques at different energies at three distinct synchrotrons was used to characterize asbestos in paraffinated lung tissues. The fast chemical imaging of the XFM beamline (Australian Synchrotron) demonstrates that asbestos bodies can be rapidly and efficiently identified as co-localization of high calcium and iron, the most abundant elements of these formations inside tissues (Fe up to 10% w/w; Ca up to 1%). By following iron presence, we were also able to hint at small asbestos fibers in pleural spaces. XRF at lower energy and at higher spatial resolution was afterwards performed to better define small fibers. These analyses may predispose for future protocols to be set with laboratory instruments.


2003 ◽  
Vol 31 (4) ◽  
pp. 819-823 ◽  
Author(s):  
V. Beaumont

There is a dizzying array of fluorescent probes now commercially available to monitor cellular processes, and advances in molecular biology have highlighted the ease with which proteins can now be labelled with fluorophores without loss of functionality. This has led to an explosion in the popularity of fluorescence microscopy techniques. One such specialized technique, total internal reflection fluorescence microscopy (TIR-FM), is ideally suited to gaining insight into events occurring at, or close to, the plasma membrane of live cells with excellent optical resolution. In the last few years, the application of TIR-FM to membrane trafficking events in both non-excitable and excitable cells has been an area of notable expansion and fruition. This review gives a brief overview of that literature, with emphasis on the study of the regulation of exocytosis and endocytosis in excitable cells using TIR-FM. Finally, recent applications of TIR-FM to the study of cellular processes at the molecular level are discussed briefly, providing promise that the future of TIR-FM in cell biology will only get brighter.


1989 ◽  
pp. 139-149
Author(s):  
Ken Jacobson ◽  
Akira Ishihara ◽  
Bruce Holifield ◽  
James DiGuiseppi

Sign in / Sign up

Export Citation Format

Share Document