scholarly journals Toward point-of-care management of chronic respiratory conditions: Electrochemical sensing of nitrite content in exhaled breath condensate using reduced graphene oxide

2017 ◽  
Vol 3 (1) ◽  
Author(s):  
Azam Gholizadeh ◽  
Damien Voiry ◽  
Clifford Weisel ◽  
Andrew Gow ◽  
Robert Laumbach ◽  
...  
10.2196/23831 ◽  
2021 ◽  
Vol 10 (7) ◽  
pp. e23831
Author(s):  
Lauren Fox ◽  
Jessica Gates ◽  
Ruth De Vos ◽  
Laura Wiffen ◽  
Alexander Hicks ◽  
...  

Background More than 7% of the world’s population is living with a chronic respiratory condition. In the United Kingdom, lung disease affects approximately 1 in 5 people, resulting in over 700,000 hospital admissions each year. People with respiratory conditions have several symptoms and can require multiple health care visits and investigations before a diagnosis is made. The tests available can be difficult to perform, especially if a person is symptomatic, leading to poor quality results. A new, easy-to-perform, point-of-care test that can be performed in any health care setting and that can differentiate between various respiratory conditions would have a significant, beneficial impact on the ability to diagnose respiratory diseases. Objective The objective of this study is to use a new handheld device (Inflammacheck) in different respiratory conditions to measure the exhaled breath condensate hydrogen peroxide (EBC H2O2) and compare these results with those of healthy controls and with each other. This study also aims to determine whether the device can measure other parameters, including breath humidity, breath temperature, breath flow dynamics, and end tidal carbon dioxide. Methods We will perform a single-visit, cross-sectional observational study of EBC H2O2 levels, as measured by Inflammacheck, in people with respiratory disease and volunteers with no known lung disease. Participants with a confirmed diagnosis of asthma, chronic obstructive pulmonary disease, lung cancer, bronchiectasis, pneumonia, breathing pattern disorder, and interstitial lung disease as well as volunteers with no history of lung disease will be asked to breathe into the Inflammacheck device to record their breath sample. Results The results from this study will be available in 2022, in anticipation of COVID-19–related delays. Conclusions This study will investigate the EBC H2O2, as well as other exhaled breath parameters, for use as a future diagnostic tool.


2020 ◽  
Author(s):  
Lauren Fox ◽  
Jessica Gates ◽  
Ruth De Vos ◽  
Laura Wiffen ◽  
Alexander Hicks ◽  
...  

BACKGROUND More than 7% of the world’s population is living with a chronic respiratory condition. In the United Kingdom, lung disease affects approximately 1 in 5 people, resulting in over 700,000 hospital admissions each year. People with respiratory conditions have several symptoms and can require multiple health care visits and investigations before a diagnosis is made. The tests available can be difficult to perform, especially if a person is symptomatic, leading to poor quality results. A new, easy-to-perform, point-of-care test that can be performed in any health care setting and that can differentiate between various respiratory conditions would have a significant, beneficial impact on the ability to diagnose respiratory diseases. OBJECTIVE The objective of this study is to use a new handheld device (Inflammacheck) in different respiratory conditions to measure the exhaled breath condensate hydrogen peroxide (EBC H<sub>2</sub>O<sub>2</sub>) and compare these results with those of healthy controls and with each other. This study also aims to determine whether the device can measure other parameters, including breath humidity, breath temperature, breath flow dynamics, and end tidal carbon dioxide. METHODS We will perform a single-visit, cross-sectional observational study of EBC H<sub>2</sub>O<sub>2</sub> levels, as measured by Inflammacheck, in people with respiratory disease and volunteers with no known lung disease. Participants with a confirmed diagnosis of asthma, chronic obstructive pulmonary disease, lung cancer, bronchiectasis, pneumonia, breathing pattern disorder, and interstitial lung disease as well as volunteers with no history of lung disease will be asked to breathe into the Inflammacheck device to record their breath sample. RESULTS The results from this study will be available in 2022, in anticipation of COVID-19–related delays. CONCLUSIONS This study will investigate the EBC H<sub>2</sub>O<sub>2</sub>, as well as other exhaled breath parameters, for use as a future diagnostic tool.


2018 ◽  
Vol 44 (3) ◽  
pp. 256-266 ◽  
Author(s):  
Don R. Bergfelt ◽  
John Lippolis ◽  
Michel Vandenplas ◽  
Sydney Davis ◽  
Blake A. Miller ◽  
...  

2020 ◽  
Vol 16 (7) ◽  
pp. 872-879
Author(s):  
Samin Hamidi

Background: Abuse of drugs is associated with several medical, forensic, toxicology and social challenges. “Drugs of abuse” testing is therefore an important issue. Objective: We propose a simple CE-based method for the quantification of amphetamine, codeine and morphine after direct injection of Exhaled Breath Condensate (EBC) by the aid of simple stacking mode and an off-line pre-concentration method. Methods: Using graphene oxide adsorbents, amphetamine, codeine and morphine were extracted from EBC in order to eliminate the proteins and other interferences. In addition to off-line method, an online stacking mode was applied to improve the analytical signal obtained from the instrument. Results: The validation parameters were experimented on the developed method based on the FDA guideline over concentration ranges of 12.5-100, 30-500 and 10-1250 ng/mL associated with amphetamine, codeine and morphine, respectively. Small volumes (around 100 μL) of EBC were collected using a lab-made setup and successfully analyzed using the proposed method where precisions and accuracies (within day and between days) were in accordance with the guideline (recommended less than 15 % for biological samples). The recovery tests were used to evaluate the matrix effect and data (94 to 105 %) showed that the proposed method can be applied in different EBC matrix samplings of subjects. Conclusion: The proposed method is superior for simultaneous determination of amphetamine, codeine and morphine over chromatographic analyses because it is fast and consumes fewer chemicals, with no derivatization step.


2020 ◽  
Vol 16 (8) ◽  
pp. 1032-1040
Author(s):  
Laleh Samini ◽  
Maryam Khoubnasabjafari ◽  
Mohamad M. Alimorad ◽  
Vahid Jouyban-Gharamaleki ◽  
Hak-Kim Chan ◽  
...  

Background: Analysis of drug concentrations in biological fluids is required in clinical sciences for various purposes. Among other biological samples, exhaled breath condensate (EBC) is a potential sample for follow up of drug concentrations. Methods: A dispersive liquid-liquid microextraction (DLLME) procedure followed by a validated liquid chromatography method was employed for the determination of budesonide (BDS) in EBC samples collected using a homemade setup. EBC is a non-invasive biological sample with possible applications for monitoring drug concentrations. The proposed analytical method is validated according to the FDA guidelines using EBC-spiked samples. Its applicability is tested on EBC samples collected from healthy volunteers receiving a single puff of BDS. Results: The best DLLME conditions involved the use of methanol (1 mL) as a disperser solvent, chloroform (200 μL) as an extraction solvent, and centrifugation rate of 3500 rpm for 5 minutes. The method was validated over a concentration range of 21-210 μg·L-1 in EBC. Inter- and intra-day precisions were less than 10% where the acceptable levels are less than 20%. The validated method was successfully applied for the determination of BDS in EBC samples. Conclusion: The findings of this study indicate that the developed method can be used for the extraction and quantification of BDS in EBC samples using a low cost method.


2019 ◽  
Vol 15 (5) ◽  
pp. 535-541 ◽  
Author(s):  
Fariba Pourkarim ◽  
Ali Shayanfar ◽  
Maryam Khoubnasabjafari ◽  
Fariborz Akbarzadeh ◽  
Sanaz Sajedi-Amin ◽  
...  

Background:Developing a simple analysis method for quantification of drug concentration is one of the essential issues in pharmacokinetic and therapeutic drug monitoring studies.Objective:A fast and reliable dispersive liquid-liquid microextraction procedure was employed for preconcentration of verapamil in exhaled breath condensate (EBC) samples and this was followed by the determination with high-performance liquid chromatography-ultraviolet detection.Methods:A reverse-phase high-performance liquid chromatography (RP-HPLC) combined with a dispersive liquid-liquid microextraction method (DLLME) was applied for quantification of verapamil in the EBC samples. The developed method was validated according to FDA guidelines.Results:Under the optimum conditions, the method provided a linear range between 0.07 and 0.8 µg.mL-1 with a coefficient of determination of 0.998. The intra- and inter-day relative standard deviation and relative error values of the method were below 15%, which indicated good precision and accuracy. The proposed method was successfully applied for the analysis of verapamil in two real samples with concentrations of 0.07 and 0.09 µg.mL-1.Conclusion:The established HPLC-UV-DLLME method could be applied for the analysis of verapamil in human EBC samples.


2019 ◽  
Vol 75 (2) ◽  
pp. 65-69 ◽  
Author(s):  
Chieh-Ming Wu ◽  
Anna Adetona ◽  
Chi (Chuck) Song ◽  
Luke Naeher ◽  
Olorunfemi Adetona