scholarly journals Noninvasive and Quantitative Assessment of the Function of Multidrug Resistance-Associated Protein 1 in the Living Brain

2008 ◽  
Vol 29 (3) ◽  
pp. 504-511 ◽  
Author(s):  
Toshimitsu Okamura ◽  
Tatsuya Kikuchi ◽  
Maki Okada ◽  
Chie Toramatsu ◽  
Kiyoshi Fukushi ◽  
...  

Multidrug resistance-associated protein 1 (MRP1) acts as a defense mechanism by pumping xenobiotics and endogenous metabolites out of the brain. The currently available techniques for studying brain-to-blood efflux have significant limitations related to either their invasiveness or the qualitative assessment. Here, we describe an in vivo method, which overcomes these limitations for assessing MRP1 function, using positron emission tomography (PET) and a PET probe. 6-Bromo-7-[11C]methylpurine was designed to readily enter the brain after intravenous administration and to be efficiently converted to its glutathione conjugate (MRP1 substrate) in situ. Dynamic PET scan provided the brain time—activity curve after injection of 6-bromo-7-[11C]methylpurine into mice. The efflux rate of the substrate was kinetically estimated to be 1.4 h−1 with high precision. Moreover, knockout of Mrp1 gene caused approximately a 90% reduction of the efflux rate, compared with wild-type mice. In conclusion, our method allows noninvasive and quantitative assessment for MRP1 function in the living brain.

Molecules ◽  
2020 ◽  
Vol 25 (10) ◽  
pp. 2289
Author(s):  
Naresh Damuka ◽  
Paul Czoty ◽  
Ashley Davis ◽  
Michael Nader ◽  
Susan Nader ◽  
...  

Dysregulation of microtubules is commonly associated with several psychiatric and neurological disorders, including addiction and Alzheimer’s disease. Imaging of microtubules in vivo using positron emission tomography (PET) could provide valuable information on their role in the development of disease pathogenesis and aid in improving therapeutic regimens. We developed [11C]MPC-6827, the first brain-penetrating PET radiotracer to image microtubules in vivo in the mouse brain. The aim of the present study was to assess the reproducibility of [11C]MPC-6827 PET imaging in non-human primate brains. Two dynamic 0–120 min PET/CT imaging scans were performed in each of four healthy male cynomolgus monkeys approximately one week apart. Time activity curves (TACs) and standard uptake values (SUVs) were determined for whole brains and specific regions of the brains and compared between the “test” and “retest” data. [11C]MPC-6827 showed excellent brain uptake with good pharmacokinetics in non-human primate brains, with significant correlation between the test and retest scan data (r = 0.77, p = 0.023). These initial evaluations demonstrate the high translational potential of [11C]MPC-6827 to image microtubules in the brain in vivo in monkey models of neurological and psychiatric diseases.


Cancers ◽  
2021 ◽  
Vol 13 (10) ◽  
pp. 2342
Author(s):  
Corentin Martens ◽  
Olivier Debeir ◽  
Christine Decaestecker ◽  
Thierry Metens ◽  
Laetitia Lebrun ◽  
...  

Recent works have demonstrated the added value of dynamic amino acid positron emission tomography (PET) for glioma grading and genotyping, biopsy targeting, and recurrence diagnosis. However, most of these studies are based on hand-crafted qualitative or semi-quantitative features extracted from the mean time activity curve within predefined volumes. Voxelwise dynamic PET data analysis could instead provide a better insight into intra-tumor heterogeneity of gliomas. In this work, we investigate the ability of principal component analysis (PCA) to extract relevant quantitative features from a large number of motion-corrected [S-methyl-11C]methionine ([11C]MET) PET frames. We first demonstrate the robustness of our methodology to noise by means of numerical simulations. We then build a PCA model from dynamic [11C]MET acquisitions of 20 glioma patients. In a distinct cohort of 13 glioma patients, we compare the parametric maps derived from our PCA model to these provided by the classical one-compartment pharmacokinetic model (1TCM). We show that our PCA model outperforms the 1TCM to distinguish characteristic dynamic uptake behaviors within the tumor while being less computationally expensive and not requiring arterial sampling. Such methodology could be valuable to assess the tumor aggressiveness locally with applications for treatment planning and response evaluation. This work further supports the added value of dynamic over static [11C]MET PET in gliomas.


Biomedicines ◽  
2021 ◽  
Vol 9 (3) ◽  
pp. 252
Author(s):  
Jacopo Meldolesi

Biomarkers are molecules that are variable in their origin, nature, and mechanism of action; they are of great relevance in biology and also in medicine because of their specific connection with a single or several diseases. Biomarkers are of two types, which in some cases are operative with each other. Fluid biomarkers, started around 2000, are generated in fluid from specific proteins/peptides and miRNAs accumulated within two extracellular fluids, either the central spinal fluid or blood plasma. The switch of these proteins/peptides and miRNAs, from free to segregated within extracellular vesicles, has induced certain advantages including higher levels within fluids and lower operative expenses. Imaging biomarkers, started around 2004, are identified in vivo upon their binding by radiolabeled molecules subsequently revealed in the brain by positron emission tomography and/or other imaging techniques. A positive point for the latter approach is the quantitation of results, but expenses are much higher. At present, both types of biomarker are being extensively employed to study Alzheimer’s and other neurodegenerative diseases, investigated from the presymptomatic to mature stages. In conclusion, biomarkers have revolutionized scientific and medical research and practice. Diagnosis, which is often inadequate when based on medical criteria only, has been recently improved by the multiplicity and specificity of biomarkers. Analogous results have been obtained for prognosis. In contrast, improvement of therapy has been limited or fully absent, especially for Alzheimer’s in which progress has been inadequate. An urgent need at hand is therefore the progress of a new drug trial design together with patient management in clinical practice.


Author(s):  
Eduardo Rigon Zimmer ◽  
Antoine Leuzy ◽  
Serge Gauthier ◽  
Pedro Rosa-Neto

ABSTRACTThe presence of neurofibrillary tangles in the brain is a hallmark feature of several neurodegenerative diseases termed “tauopathies,” including Alzheimer’s disease (AD) and the tau molecular subgroup of frontotemporal lobar degeneration (FTLD-tau). Recently, several positron emission tomography (PET) radiopharmaceuticals targeting abnormal conformations of the tau protein have been developed. To date, six novel tau imaging agents—[18F]THK523, [18F]THK5105, [18F]THK5117, [18F]T807, [18F]T808, and [11C]PBB3—have been described and are considered promising as potential tau radioligands. Tau imaging agents offer the opportunity of in vivo topographical mapping and quantification of tau aggregates in parallel with clinical and cognitive assessments. As such, tau imaging is considered of key importance for progress toward earlier and more accurate diagnosis of tauopathies as well as for the monitoring of therapeutic interventions and drug development. Here, we shed light on the most important developments in tau radiopharmaceuticals, highlighting challenges, possibilities and future directions.


2016 ◽  
Vol 37 (6) ◽  
pp. 2185-2195 ◽  
Author(s):  
Sylvain Auvity ◽  
Hélène Chapy ◽  
Sébastien Goutal ◽  
Fabien Caillé ◽  
Benoit Hosten ◽  
...  

Diphenhydramine, a sedative histamine H1-receptor (H1R) antagonist, was evaluated as a probe to measure drug/H+-antiporter function at the blood–brain barrier. In situ brain perfusion experiments in mice and rats showed that diphenhydramine transport at the blood–brain barrier was saturable, following Michaelis–Menten kinetics with a Km = 2.99 mM and Vmax = 179.5 nmol s−1 g−1. In the pharmacological plasma concentration range the carrier-mediated component accounted for 77% of diphenhydramine influx while passive diffusion accounted for only 23%. [14C]Diphenhydramine blood–brain barrier transport was proton and clonidine sensitive but was influenced by neither tetraethylammonium, a MATE1 (SLC47A1), and OCT/OCTN (SLC22A1-5) modulator, nor P-gp/Bcrp (ABCB1a/1b/ABCG2) deficiency. Brain and plasma kinetics of [11C]diphenhydramine were measured by positron emission tomography imaging in rats. [11C]Diphenhydramine kinetics in different brain regions were not influenced by displacement with 1 mg kg−1 unlabeled diphenhydramine, indicating the specificity of the brain positron emission tomography signal for blood–brain barrier transport activity over binding to any central nervous system target in vivo. [11C]Diphenhydramine radiometabolites were not detected in the brain 15 min after injection, allowing for the reliable calculation of [11C]diphenhydramine brain uptake clearance (Clup = 0.99 ± 0.18 mL min−1 cm−3). Diphenhydramine is a selective and specific H+-antiporter substrate. [11C]Diphenhydramine positron emission tomography imaging offers a reliable and noninvasive method to evaluate H+-antiporter function at the blood–brain barrier.


2018 ◽  
Vol 314 (5) ◽  
pp. E413-E417 ◽  
Author(s):  
Qiaojun Han ◽  
Yanli Cao ◽  
Nicola Gathaiya ◽  
Bradley J. Kemp ◽  
Michael D. Jensen

PET radiopharmaceuticals can noninvasively measure free fatty acid (FFA) tissue uptake. Investigators often use PET scan-derived data to calculate FFA flux. We tested whether the [1-11C]palmitate PET measures of palmitate flux provide results equivalent to a continuous infusion of [U-13C]palmitate. Nine volunteers participated in study 1 to evaluate whether a rapidly (10–20 s) given bolus of [1-11C]palmitate affects calculated flux results. Thirty volunteers participated in study 2, which was identical to study 1 except that the [1-11C]palmitate bolus was given over 1 min. Volunteers in both studies also received a continuous intravenous infusion of [U-13C]palmitate. Plasma palmitate concentrations and enrichment were measured by liquid chromatography-mass spectrometry. The PET/CT images were analyzed on a workstation running PMOD. Palmitate flux was estimated using PET time-activity curve (TAC) data from regions of interest in the left ventricle (LV) and aorta both with and without hybrid TACs that employed the 11CO2-corrected data for the first 5 min and the 11CO2-corrected blood radioactivity for the remainder of the PET scan. Palmitate flux in study 1 measured with PET [1-11C]palmitate and [U-13C]palmitate were not correlated, and the PET [1-11C]palmitate flux was significantly less than the [U-13C]palmitate measured flux. In study 2, the palmitate flux using PET [1-11C]palmitate hybrid LV models provided closer mean estimates of [U-13C]palmitate measured flux. The best PET calculation approaches predicted 64% of the interindividual variance in [U-13C]palmitate measured flux. Palmitate kinetics measured using [1-11C]palmitate/PET do not provide the same palmitate kinetic results as the continuous infusion [U-13C]palmitate approach.


2015 ◽  
Vol 35 (12) ◽  
pp. 1930-1936 ◽  
Author(s):  
Toshimitsu Okamura ◽  
Maki Okada ◽  
Tatsuya Kikuchi ◽  
Hidekatsu Wakizaka ◽  
Ming-Rong Zhang

A disturbance in redox balance has been implicated in the pathogenesis of a number of diseases. This study sought to examine the feasibility of imaging brain redox status using a 11C-labeled dihydroquinoline derivative ([11C]DHQ1) for positron emission tomography (PET). The lipophilic PET tracer [11C]DHQ1 was rapidly oxidized to its hydrophilic form in mouse brain homogenate. The redox modulators diphenyleneiodonium and apocynin significantly reduced the initial velocity of [11C]DHQ1 oxidation, and apocynin also caused concentration-dependent inhibition of the initial velocity. Moreover, [11C]DHQ1 readily entered the brain by diffusion after administration and underwent oxidation into the hydrophilic cationic form, which then slowly decreased. By contrast, apocynin treatment inhibited the in vivo oxidation of [11C]DHQ1 to the hydrophilic cationic form, leading to a rapid decrease of radioactivity in the brain. Thus, the difference in the [11C]DHQ1 kinetics reflects the alteration in redox status caused by apocynin. In conclusion, [11C]DHQ1 is a potential PET tracer for imaging of redox status in the living brain.


Molecules ◽  
2019 ◽  
Vol 24 (15) ◽  
pp. 2791 ◽  
Author(s):  
Ritawidya ◽  
Ludwig ◽  
Briel ◽  
Brust ◽  
Scheunemann

Phosphodiesterase 2A (PDE2A) is highly expressed in distinct areas of the brain, which are known to be related to neuropsychiatric diseases. The development of suitable PDE2A tracers for Positron Emission Tomography (PET) would permit the in vivo imaging of the PDE2A and evaluation of disease-mediated alterations of its expression. A series of novel fluorinated PDE2A inhibitors on the basis of a Benzoimidazotriazine (BIT) scaffold was prepared leading to a prospective inhibitor for further development of a PDE2A PET imaging agent. BIT derivatives (BIT1–9) were obtained by a seven-step synthesis route, and their inhibitory potency towards PDE2A and selectivity over other PDEs were evaluated. BIT1 demonstrated much higher inhibition than other BIT derivatives (82.9% inhibition of PDE2A at 10 nM). BIT1 displayed an IC50 for PDE2A of 3.33 nM with 16-fold selectivity over PDE10A. This finding revealed that a derivative bearing both a 2-fluoro-pyridin-4-yl and 2-chloro-5-methoxy-phenyl unit at the 8- and 1-position, respectively, appeared to be the most potent inhibitor. In vitro studies of BIT1 using mouse liver microsomes (MLM) disclosed BIT1 as a suitable ligand for 18F-labeling. Nevertheless, future in vivo metabolism studies are required.


Sign in / Sign up

Export Citation Format

Share Document