scholarly journals Comparison of Scheimpflug imaging and spectral domain anterior segment optical coherence tomography for detection of narrow anterior chamber angles

Eye ◽  
2011 ◽  
Vol 25 (5) ◽  
pp. 603-611 ◽  
Author(s):  
D S Grewal ◽  
G S Brar ◽  
R Jain ◽  
S P S Grewal
2018 ◽  
Vol 1 ◽  
pp. 3
Author(s):  
Joshua S Agranat ◽  
Yoshihiro Yonekawa

Iris pigment epithelial (IPE) cysts are a subset of iris cysts that arise from the IPE. They are spontaneously erupting epithelial-lined cavities that are found in various anatomic locations of the iris, including the iris pupillary margin, midzone, periphery, and free floating in the vitreous or anterior chamber. We report the case of an asymptomatic 13-year-old boy with an incidental finding of a dislodged anterior chamber cyst diagnosed on routine examination. Modern multimodal image analysis of the cyst including anterior segment optical coherence tomography and ultrasound biomicroscopy (UBM) was utilized to characterize the microstructural anatomy of the lesion. The patient was managed conservatively without complications. Cysts of the IPE typically do not affect vision or ocular health and can be monitored and observed after ascertaining no associated malignancy. Initial diagnostic investigation can include UBM and anterior segment optical coherence tomography. Intervention should be reserved only for cases where the cyst growth leads to obstruction of the visual axis and/or other secondary complications.


Author(s):  
Alireza Khodabande ◽  
Massood Mohammadi ◽  
Hamid Riazi-Esfahani ◽  
Shahab Karami ◽  
Massood Mirghorbani ◽  
...  

Abstract Background To evaluate changes in anterior segment morphology on anterior segment optical coherence tomography (AS-OCT) following pars plana vitrectomy (PPV) without tamponade. Methods Patients who underwent PPV without tamponade for epiretinal membrane were evaluated. Eligible patients underwent intraocular pressure (IOP) measurement and AS-OCT preoperatively as well as 1 month and 6 months post-operatively. Anterior chamber width (ACW), anterior chamber depth (ACD), trabecular iris angle (TIA), angle opening distance at 500 and 750 µm (AOD), and trabecular iris space area at 500 and 750 µm (TISA) at four quadrants were recorded and analyzed. Additionally, the mean values of TIA (MTIA), AOD (MAOD), and TISA (MTISA) for each eye (mean of four quadrants) were analyzed. Results 23 patients completed the study. The mean age of participants was 56.4 ± 3.6 years of age and 13/23 (56%) were female. Mean IOP of patients was 18.1 ± 1.1, 18.3 ± 1.1, and 18.1 ± 1.2 preoperatively,1 month post-operatively, and 6 months post-operatively, respectively. (p = 0.83). No difference was detected post-operatively in measurements of ACW, ACD, MTIA, MAOD500, MAOD750, MTISA500, and MTISA750. Conclusion Pars plana vitrectomy without tamponade was not associated with changes in anterior chamber morphology.


2016 ◽  
Vol 57 (2) ◽  
pp. 87-91 ◽  
Author(s):  
Jie Lan ◽  
Dapeng Sun ◽  
Khatoon Alabdulrasool ◽  
Hassan Ebrahim Yusuf ◽  
Lu Zhang

2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Riham S. H. M. Allam ◽  
Rania A. Ahmed

Purpose. To study features of the lower punctum in normal subjects using spectral domain anterior segment optical coherence tomography (SD AS-OCT).Methods. Observational cross-sectional study that included 147 punctae (76 subjects). Punctae were evaluated clinically for appearance, position, and size. AS-OCT was used to evaluate the punctal shape, contents, and junction with the vertical canaliculus. Inner and outer diameters as well as depth were measured.Results. 24 males and 52 females (mean age44±14.35 y) were included. Lower punctum was perceived by OCT to be an area with an outer diameter (mean412.16±163 μm), inner diameter (mean233.67±138.73 μm), and depth (mean251.7±126.58 μm). The OCT measured outer punctum diameter was significantly less than that measured clinically (P: 0.000). Seven major shapes were identified. The junction with the vertical canaliculus was detectable in 44%. Fluid was detected in 34%, one of which had an air bubble; however, 63% of punctae showed no contents and 4% had debris.Conclusions. AS-OCT can be a useful tool in understanding the anatomy of the punctum and distal lacrimal system as well as tear drainage physiology. Measuring the punctum size may play a role in plugs fitting.


Cornea ◽  
2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Elias Flockerzi ◽  
Berit Elzer ◽  
Loay Daas ◽  
Kassandra Xanthopoulou ◽  
Timo Eppig ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document