Hemoglobin-based blood substitutes: oxygen carriers, pressor agents, or oxidants?

10.1038/9849 ◽  
1999 ◽  
Vol 17 (6) ◽  
pp. 545-549 ◽  
Author(s):  
Abdu I. Alayash
2008 ◽  
Vol 44 ◽  
pp. 63-84 ◽  
Author(s):  
Chris E. Cooper

Optimum performance in aerobic sports performance requires an efficient delivery to, and consumption of, oxygen by the exercising muscle. It is probable that maximal oxygen uptake in the athlete is multifactorial, being shared between cardiac output, blood oxygen content, muscle blood flow, oxygen diffusion from the blood to the cell and mitochondrial content. Of these, raising the blood oxygen content by raising the haematocrit is the simplest acute method to increase oxygen delivery and improve sport performance. Legal means of raising haematocrit include altitude training and hypoxic tents. Illegal means include blood doping and the administration of EPO (erythropoietin). The ability to make EPO by genetic means has resulted in an increase in its availability and use, although it is probable that recent testing methods may have had some impact. Less widely used illegal methods include the use of artificial blood oxygen carriers (the so-called ‘blood substitutes’). In principle these molecules could enhance aerobic sports performance; however, they would be readily detectable in urine and blood tests. An alternative to increasing the blood oxygen content is to increase the amount of oxygen that haemoglobin can deliver. It is possible to do this by using compounds that right-shift the haemoglobin dissociation curve (e.g. RSR13). There is a compromise between improving oxygen delivery at the muscle and losing oxygen uptake at the lung and it is unclear whether these reagents would enhance the performance of elite athletes. However, given the proven success of blood doping and EPO, attempts to manipulate these pathways are likely to lead to an ongoing battle between the athlete and the drug testers.


2007 ◽  
Vol 131 (5) ◽  
pp. 734-741
Author(s):  
Paul M. Ness ◽  
Melissa M. Cushing

Abstract Context.—There is no true substitute for the many functions of human red blood cells, and synthetic products will not replace the need for blood donation in the foreseeable future. Hemoglobin-based oxygen carriers have many characteristics that would serve as a useful adjunct to red cells in clinical settings. Over time, these technologies have the potential to dramatically reshape the practice of transfusion medicine. Objective.—To review the characteristics and potential utility of hemoglobin-based oxygen carriers and perfluorocarbon-based oxygen carriers. Several hemoglobin-based oxygen carriers are under study in phase III clinical trials. Novel uses for synthetic oxygen therapeutics are emphasized. Data Sources.—All published reports with the key words oxygen therapeutics, blood substitutes, and red cell substitutes from 1933 until March 2006 were searched through Medline. Significant findings were synthesized. Conclusions.—Recognition of the true impact of red cell substitutes is still several years away. The most compelling products, hemoglobin-based oxygen carriers, have potential use in trauma, providing immediate oxygen-carrying support in the face of alloantibodies or autoantibodies, and in other clinical situations in which long-term survival of red cells is not essential. In the interim, efforts should be focused on enhancing the current blood supply system while supporting ongoing and planned blood substitute research efforts, including trials assessing novel clinical indications for these products.


Stroke ◽  
2013 ◽  
Vol 44 (suppl_1) ◽  
Author(s):  
Sean D Woods ◽  
Robert D Skinner ◽  
Aliza T Brown ◽  
Aaron M Ricca ◽  
Jennifer L Johnson ◽  
...  

Introduction: Neuroprotective strategies in ischemic stroke include oxygen delivery to sustain penumbra and prevent hypoxic cell death. Hyperbaric oxygen, blood substitutes, and liquid fluorocarbon-based oxygen carriers have often failed in treatment of stroke and other ischemic disorders. Dodecafluoropentane emulsion (DDFPe, boiling point 29°C) shifts to quasi-gas phase at body temperature, which allows absorption and transportation of very high levels of oxygen. Exceptionally small particle size, 250-300 nm, may allow oxygen delivery even through occluded vessels, by diffusion into hypoxic tissue unreachable by whole blood. In a preliminary stroke study in rabbits, DDFPe reduced infarct volumes in all experimental groups by 80% or more. Hypothesis: Repeated doses of DDFPe can reduce infarct volume for up to 24 hours after permanent cerebral artery occlusion in rabbits. Methods: New Zealand White rabbits (N=55) received cerebral angiography from a femoral artery approach. Embolic microspheres (diameter=700-900 μm) were injected into the internal carotid artery, permanently occluding the middle cerebral and/or anterior cerebral arteries. Rabbits were randomly assigned to treatment groups and sacrifice times as in Table 1. In all treated groups, intravenous DDFPe dosing with a 2% w/v emulsion began at 1 hour post-embolization and was repeated every 90 minutes until sacrifice at either 7 or 24 hours post-embolization. Following sacrifice, infarcts were measured as a percent of brain volume using vital stains on brain sections. Results: Percent infarct volume means significantly decreased for all DDFPe treated groups compared with controls (Table 1). Conclusion: Intravenous DDFPe begun 1 hour after stroke onset protects the brain from ischemic injury in the rabbit model of permanent embolic stroke. Decreased infarct volumes represent salvaged brain tissue. This effect can be observed for 24 hours with repeated doses.


1996 ◽  
Vol 85 (2) ◽  
pp. 248-254 ◽  
Author(s):  
Damianos E. Sakas ◽  
Karl W. Whittaker ◽  
Robert M. Crowell ◽  
Nicholas T. Zervas

✓ Over the last 30 years, perfluorocarbons (PFCs) have been extensively investigated as oxygen carriers. Early studies indicated that these compounds could be used as blood substitutes or protective agents against ischemia. Adverse characteristics such as instability, short intravascular half-life, and uncertainties concerning possible toxicity precluded wide clinical application. However, advances in PFC technology have led to the development of improved second-generation oxygen carriers that incorporate well-tolerated emulsifiers (egg-yolk phospholipids). The authors review recent developments in this field and consider the potential role of PFCs in future neurosurgical practice. Diagnostic applications could include their use to assess cerebral blood flow, local oxygen tension, and brain metabolism or to achieve enhanced imaging and precise staging of inflammatory, neoplastic, or vascular disease processes by means of computerized tomography, ultrasonography, and magnetic resonance studies. Therapeutic applications could include cerebral protection, an adjunctive role in radiotherapy of malignant brain tumors, protection against air embolism, the preservation of organs for transplantation, and ventilatory support in head-injured patients with compromised lung function. In addition, PFCs have been used successfully as a tool in ophthalmic microsurgery and potentially they could fulfill a similar role in microneurosurgery.


Author(s):  
Sara Emily Bachert ◽  
Prerna Dogra ◽  
Leonard I Boral

Abstract Objectives We discuss two main categories of blood substitutes: perfluorocarbons and hemoglobin-based oxygen carriers. Methods We provide a review of the notable products developed in both categories and include their attributes as well as their setbacks. Results We contribute a case report tothe growing literature of the successful use of Sanguinate. Conclusions We find that artificial oxygen carriers are an attractive field of research because of the practical limitations and the multitude of potential complications that surround human blood transfusions.


1998 ◽  
Vol 357 ◽  
pp. 89-100 ◽  
Author(s):  
Lawrence T. Goodnough ◽  
Mitchell G. Scott ◽  
Terri G. Monk

1985 ◽  
Vol 248 (4) ◽  
pp. E432-E437
Author(s):  
C. Chubb ◽  
P. Draper

Organs perfused in vitro are important experimental models for physiological studies. Perfusion medium supplemented with artificial oxygen carriers would at physiological flow rates supply sufficient oxygen to organs and would be superior to medium containing erythrocytes because it is more defined. Perfluorotributylamine (FC-43), a perfluorochemical, is an artificial oxygen carrier that has been previously reported to be ineffective in maintaining endocrine organs perfused in vitro. The purpose of this study was to determine the efficacy of FC-43 as an oxygen carrier for rat testes perfused in vitro. The effects of FC-43 on testicular function and structure were assessed by comparing the results of experiments using perfusion medium containing either FC-43 or erythrocytes. The results suggest that perfusion medium containing perfluorochemicals must be prepared by standardized procedures and defined as to its physiochemical parameters. The study resulted in the first successful in vitro perfusion of an endocrine organ with perfluorochemicals as oxygen carriers. The results not only provide the basis for an improved perfusion medium but also support in vitro perfused testes as effective experimental tools for testing perfluorochemical-based blood substitutes.


2004 ◽  
Vol 18 (7) ◽  
pp. 441-448 ◽  
Author(s):  
Shunichi Takahata ◽  
Hiroyuki Konomi ◽  
Ann C Schloithe ◽  
James Toouli ◽  
Gino TP Saccone

BACKGROUND:Several studies have investigated the effects of hemoglobin-based oxygen carriers on gastrointestinal motility. Diaspirin cross-linked hemoglobin reduces sphincter of Oddi trans-sphincteric flow and increases duodenal motility in the Australian brush-tailed possum, effects attributed to nitric oxide (NO) scavenging. Recently, second-generation recombinant hemoglobin molecules with reduced NO scavenging ability have been developed.AIM:To determine the effects of two second-generation recombinant hemoglobin solutions and the prototype recombinant hemoglobin with high NO binding, on duodenal and biliary motility in the Australian brush-tailed possum.METHOD:Blood pressure; duodenal, sphincter of Oddi and gallbladder motility; and trans-sphincteric flow were recorded. The effects of recombinant hemoglobin or human serum albumin (control) solutions on these parameters were investigated. Each solution was infused intravenously at 1 mL/kg/min to deliver 250 mg/kg or 500 mg/kg.RESULTS:Duodenal contraction frequency was stimulated by the high dose of prototype recombinant hemoglobin, but not by a comparable dose of second-generation recombinant hemoglobin. The induced duodenal activity occurred in the later phase of the experimental period. In contrast, biliary motility and trans-sphincteric flow were not altered by any hemoglobin solution. The high dose of all the hemoglobin solutions elevated blood pressure, whereas the low dose solutions did not alter any parameter measured.CONCLUSION:At the doses studied, the second-generation recombinant hemoglobin with reduced NO binding capacity did not significantly alter duodenal and biliary motility, supporting the need for further studies to evaluate their potential usefulness as blood substitutes.


Sign in / Sign up

Export Citation Format

Share Document