The Unit System: A psychosocial and evaluative study

1965 ◽  
Author(s):  
Harry M. Grayson
2019 ◽  
Vol 42 (1) ◽  
pp. 223-143
Author(s):  
Víctor H. Salinas Torres ◽  
Cristián A. Vásquez ◽  
José S. Romeo

 This work presents a Bayesian approach for estimating the limiting availability of an one-unit repairable system. A Bayesian analysis is developed considering an informative prior and a less informative prior distribution, respectively. Simulations are presented to study the performance of the Bayesian solutions. The maximum likelihood method is also revisited. Finally, a case study is considered, the Bayesian methodology is applied to estimate the limiting availability of a palletizer, which is used in the packaging of glass bottles. Extensions to a coherent system are also discussed.


The main aim of this research work is to present a reliability and availability analysis of a three-unit system (A, As , B) under the provision of replacement of a unit using the Genetic algorithm. One unit is in standby mode so that after the failure of one unit it can be active. But one unit which is dissimilar to the previous one can be replaced with the new one after the failure. It has been considered that there is only one repair man availability within the organization. Here in this paper we have used the Genetic algorithm for finding out the optimized availability of the system and also with the assistance of numbers of graphs we have analyzed reliability characteristics, availability of the framework, so the result of the paper will be very useful for the industry people.


Author(s):  
R. C. Moretz ◽  
G. G. Hausner ◽  
D. F. Parsons

Electron microscopy and diffraction of biological materials in the hydrated state requires the construction of a chamber in which the water vapor pressure can be maintained at saturation for a given specimen temperature, while minimally affecting the normal vacuum of the remainder of the microscope column. Initial studies with chambers closed by thin membrane windows showed that at the film thicknesses required for electron diffraction at 100 KV the window failure rate was too high to give a reliable system. A single stage, differentially pumped specimen hydration chamber was constructed, consisting of two apertures (70-100μ), which eliminated the necessity of thin membrane windows. This system was used to obtain electron diffraction and electron microscopy of water droplets and thin water films. However, a period of dehydration occurred during initial pumping of the microscope column. Although rehydration occurred within five minutes, biological materials were irreversibly damaged. Another limitation of this system was that the specimen grid was clamped between the apertures, thus limiting the yield of view to the aperture opening.


Author(s):  
V. Castano ◽  
W. Krakow

In non-UHV microscope environments atomic surface structure has been observed for flat-on for various orientations of Au thin films and edge-on for columns of atoms in small particles. The problem of oxidation of surfaces has only recently been reported from the point of view of high resolution microscopy revealing surface reconstructions for the Ag2O system. A natural extension of these initial oxidation studies is to explore other materials areas which are technologically more significant such as that of Cu2O, which will now be described.


Author(s):  
Yimei Zhu ◽  
Masaki Suenaga ◽  
R. L. Sabatini ◽  
Youwen Xu

The (110) twin structure of YBa2Cu3O7 superconductor oxide, which is formed to reduce the strain energy of the tetragonal to orthorhombic phase transformation by alternating the a-b crystallographic axis across the boundary, was extensively investigated. Up to now the structure of the twin boundary still remained unclear. In order to gain insight into the nature of the twin boundary in Y-Ba-Cu-O system, a study using electron diffraction techniques including optical and computed diffractograms, as well as high resolution structure imaging techniques with corresponding computer simulation and processing was initiated.Bulk samples of Y-Ba-Cu-O oxide were prepared as described elsewhere. TEM specimens were produced by crushing bulk samples into a fine powder, dispersing the powder in acetone, and suspending the fine particles on a holey carbon grid. The electron microscopy during this study was performed on both a JEOL 2000EX and 2000FX electron microscopes operated at 200 kV.


1976 ◽  
Vol 7 (4) ◽  
pp. 207-219 ◽  
Author(s):  
Constance P. DesRoches

A statistical review provides analysis of four years of speech therapy services of a suburban school system which can be used for comparison with other school system programs. Included are data on the percentages of the school population enrolled in therapy, the categories of disabilities and the number of children in each category, the sex and grade-level distribution of those in therapy, and shifts in case-load selection. Factors affecting changes in case-load profiles are identified and discussed.


2006 ◽  
Vol 175 (4S) ◽  
pp. 323-324 ◽  
Author(s):  
Joseph Dall'era ◽  
Sweaty Koul ◽  
Jesse Mills ◽  
Jeremy Myers ◽  
Randall B. Meacham ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document