Aluminum thiolate complexes of porphyrin as excellent initiators for Lewis acid-assisted high-speed living polymerization of methyl methacrylate

1993 ◽  
Vol 26 (6) ◽  
pp. 1238-1243 ◽  
Author(s):  
Takato Adachi ◽  
Hiroshi Sugimoto ◽  
Takuzo Aida ◽  
Shohei Inoue
1996 ◽  
Vol 29 (24) ◽  
pp. 8014-8016 ◽  
Author(s):  
Yuushou Nakayama ◽  
Tetsuya Shibahara ◽  
Hiroki Fukumoto ◽  
Akira Nakamura ◽  
Kazushi Mashima

2021 ◽  
Author(s):  
Fang Ge ◽  
Sun Li ◽  
Zhe Wang ◽  
Wenzhong Zhang ◽  
Xiaowu Wang

Developing different synthetic approaches to realize controlled or living polymerization are aspirational to achieve polymers with defined molecular weight, narrow molecular weight distribution and unambiguous structures by polymer chemists. Herein,...


2021 ◽  
Vol 12 (38) ◽  
pp. 5548-5555
Author(s):  
Yun Bai ◽  
Huaiyu Wang ◽  
Jianghua He ◽  
Yuetao Zhang

The frustrated Lewis pair composed of an organophosphorus(iii) superbase and a bulky organoaluminum Lewis acid promoted the living/controlled polymerization of naturally renewable butyrolactone-based vinylidenes.


1986 ◽  
Vol 250 (1) ◽  
pp. H131-H136
Author(s):  
J. L. Heckman ◽  
L. Garvin ◽  
T. Brown ◽  
W. Stevenson-Smith ◽  
W. P. Santamore ◽  
...  

Biplane ventriculography was performed on nine intact anesthetized rats. Images of the left ventricle large enough for analysis were obtained by placing the rats close to the radiographic tubes (direct enlargement). Sampling rates, adequate for heart rates of 500 beats/min, were obtained by filming at 500 frames/s. From the digitized silhouettes of the left ventricle the following information was obtained (means +/- SE): end-diastolic volume 0.60 +/- 0.03 ml, end-systolic volume 0.22 +/- 0.02 ml, stroke volume 0.38 +/- 0.02 ml, ejection fraction 0.63 +/- 0.02, cardiac output 118 +/- 7 ml/min, diastolic septolateral dimension 0.41 +/- 0.01 mm, diastolic anteroposterior dimension 0.40 +/- 0.01 mm, diastolic base-to-apex dimension 1.58 +/- 0.04 mm. To determine the accuracy with which the volume of the ventricle could be measured, 11 methyl methacrylate casts of the left ventricle were made. The correlation was high (r = 0.99 +/- 0.02 ml E) between the cast volumes determined by water displacement and by use of two monoplane methods (Simpson's rule of integration and the area-length method applied to the analysis of the anteroposterior films) and a biplane method (area-length). These results demonstrate that it is possible to obtain accurate dimensions and volumes of the rat left ventricle by use of high-speed ventriculography.


1992 ◽  
Vol 25 (18) ◽  
pp. 4457-4463 ◽  
Author(s):  
Sunil K. Varshney ◽  
Robert Jerome ◽  
Philippe Bayard ◽  
Christian Jacobs ◽  
Roger Fayt ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document