Determination of the Lamellar Phase Content in MCM-41 Using X-ray Diffraction, Nitrogen Adsorption, and Thermogravimetry

2000 ◽  
Vol 104 (7) ◽  
pp. 1581-1589 ◽  
Author(s):  
Michal Kruk ◽  
Mietek Jaroniec ◽  
Yong Yang ◽  
Abdelhamid Sayari
2013 ◽  
Vol 779-780 ◽  
pp. 201-204
Author(s):  
Miao Li ◽  
Hong Wang ◽  
Xian Qing Li ◽  
Jin Rong Liu

Ordered hexagonally mesoporous molecular sieve Al-MCM-41 with Si/Al (atom) ratio=9 was prepared by hydrothermal synthesis using raw kaolin. X-ray diffraction (XRD), Nitrogen adsorption desorption, Transmission Electron Microscope (TEM) and Energy Dispersive X-ray Detector (EDX) were employed to characterise raw kaolin, calcined kaolin, as-synthesized and calcined Al-MCM-41. The results indicated that characteristic reflections of raw kaolin disappeared after calcination, both of as-synthesized and calcined Al-MCM-41 exhibited well ordered hexagonally mesoporous molecular sieve structure.


2006 ◽  
Vol 60 (21-22) ◽  
pp. 2682-2685 ◽  
Author(s):  
Marcelo J.B. Souza ◽  
Antonio S. Araujo ◽  
Anne M.G. Pedrosa ◽  
Bojan A. Marinkovic ◽  
Paula M. Jardim ◽  
...  

1997 ◽  
Vol 15 (1) ◽  
pp. 25-37 ◽  
Author(s):  
Th. El-Nabarawy

Ni/Al2O3 and Co/Al2O3 catalysts of different compositions have been prepared. Their structural properties were determined using X-ray diffraction and differential thermal analysis. The textural properties of these catalysts were determined from nitrogen adsorption at 77 K. The catalysts were reduced with hydrogen at 673 K and the adsorption of hydrogen on the reduced catalysts was measured at 320 K. Dehydrogenation of cyclohexane at flow rates of 10–30 ml/min and at 633–723 K was investigated. The loading of alumina with metal oxides leads to changes in the textural properties depending on the degree of loading and on the loaded metal oxide. The adsorption of hydrogen allowed the determination of important catalytic parameters. Dehydrogenation of cyclohexane on the investigated catalysts followed fraction order kinetics. The dehydrogenation activity has been related to the H2 uptake and to the extent of metal dispersion on the support.


2018 ◽  
Vol 74 (a2) ◽  
pp. e257-e257
Author(s):  
Petr Cejpek ◽  
Daniel Král ◽  
Elen Duverger-Nédellec ◽  
Lukáš Horák ◽  
Vacláv Holý

2021 ◽  
Vol 2021 ◽  
pp. 1-14
Author(s):  
Dang Thi Ngoc Hoa ◽  
Nguyen Thi Thanh Tu ◽  
Le Van Thanh Son ◽  
Le Vu Truong Son ◽  
Tran Thanh Tam Toan ◽  
...  

A facial differential pulse voltammetric procedure using a glassy carbon electrode modified with zeolite imidazolate framework-67/graphitic carbon nitride (ZIF-67/g-C3N4) for the diclofenac (DCF) determination is demonstrated. ZIF-67/g-C3N4 with different mass ratios of the components was synthesized in a self-assembly process. The obtained materials were characterized by using X-ray diffraction, scanning electron microscopy (SEM), EDX-mapping, and nitrogen adsorption/desorption isotherms. The peak current varies linearly with the DCF concentration in the range of 0.2–2.2 μmol·L−1 and has a detection limit of 0.071 μmol·L−1. The modified electrode exhibits acceptable repeatability, reproducibility, and selectivity towards DCF. The proposed electrode allows determining DCF in human urine without pretreatment, and the results are comparable with those determined with HPLC.


Sign in / Sign up

Export Citation Format

Share Document