scholarly journals How Many NOE Restraints Are Necessary for a Reliable Determination of the Relative Configuration of an Organic Compound:  Application to a Model System

1998 ◽  
Vol 63 (7) ◽  
pp. 2409-2409
Author(s):  
Matthias Köck ◽  
Jochen Junker
2001 ◽  
Vol 120 (5) ◽  
pp. A599-A599
Author(s):  
C ARNOLD ◽  
A GOEL ◽  
J CARETHERS ◽  
L WASSERMAN ◽  
C COMPTON ◽  
...  

2013 ◽  
Vol 12 (7) ◽  
pp. 460-465
Author(s):  
Sameer Amereih ◽  
Zaher Barghouthi ◽  
Lamees Majjiad

A sensitive colorimetric determination of fluoride in drinking water has been developed using a polymeric zirconium complex of 5-(2-Carboxyphenylazo)-8-Hydroxyquinoline as fluoride reagents. The method allowed a reliable determination of fluoride in range of (0.0-1.5) mg L-1. The molar absorptivity of the complex formation is 7695 ± 27 L mol-1 cm-1 at 460 nm. The sensitivity, detection limit, quantitation limit, and percentage recovery for 1.0 mg L-1 fluoride for the proposed method were found to be 0.353 ± 0.013 μg mL-1, 0.1 mg L-1, 0.3 mg L-1, and 101.7 ± 4.1, respectively.


Biosensors ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 153
Author(s):  
Georgios Koukouvinos ◽  
Chrysoula-Evangelia Karachaliou ◽  
Ioannis Raptis ◽  
Panagiota Petrou ◽  
Evangelia Livaniou ◽  
...  

Carbendazim is a systemic benzimidazole-type fungicide with broad-spectrum activity against fungi that undermine food products safety and quality. Despite its effectiveness, carbendazim constitutes a major environmental pollutant, being hazardous to both humans and animals. Therefore, fast and reliable determination of carbendazim levels in water, soil, and food samples is of high importance for both food industry and public health. Herein, an optical biosensor based on white light reflectance spectroscopy (WLRS) for fast and sensitive determination of carbendazim in fruit juices is presented. The transducer is a Si/SiO2 chip functionalized with a benzimidazole conjugate, and determination is based on a competitive immunoassay format. Thus, for the assay, a mixture of an in-house developed rabbit polyclonal anti-carbendazim antibody with the standards or samples is pumped over the chip, followed by biotinylated secondary antibody and streptavidin. The WLRS platform allows for real-time monitoring of biomolecular interactions carried out onto the Si/SiO2 chip by transforming the shift in the reflected interference spectrum caused by the immunoreaction to effective biomolecular adlayer thickness. The sensor is able to detect 20 ng/mL of carbendazim in fruit juices with high accuracy and precision (intra- and inter-assay CVs ≤ 6.9% and ≤9.4%, respectively) in less than 30 min, applying a simple sample treatment that alleviates any “matrix-effect” on the assay results and a 60 min preincubation step for improving assay sensitivity. Excellent analytical characteristics and short analysis time along with its small size render the proposed WLRS immunosensor ideal for future on-the-spot determination of carbendazim in food and environmental samples.


Molecules ◽  
2021 ◽  
Vol 26 (2) ◽  
pp. 479
Author(s):  
Shihan Wang ◽  
Yuanshuai Gan ◽  
Hong Kan ◽  
Xinxin Mao ◽  
Yongsheng Wang

As one of the featured products in northeast China, Oviductus Ranae has been widely used as a nutritious food, which contains a variety of bioactive unsaturated fatty acids (UFAs). It is necessary to establish a scientific and reliable determination method of UFA contents in Oviductus Ranae. In this work, six principal UFAs in Oviductus Ranae, namely eicosapentaenoic acid (EPA), linolenic acid (ALA), docosahexaenoic acid (DHA), arachidonic acid (ARA), linoleic acid (LA) and oleic acid (OA), were identified using UPLC-MS/MS. The UFAs identified in Oviductus Ranae were further separated based on the optimized RP-HPLC conditions. Quantitative analysis of multi-components by single-marker (QAMS) method was implemented in content determination of EPA, ALA, DHA, ARA and OA, where LA was used as the internal standard. The experiments based on Taguchi design verified the robustness of the QAMS method on different HPLC instruments and chromatographic columns. The QAMS and external standard method (ESM) were used to calculate the UFA content of 15 batches of Oviductus Ranae samples from different regions. The relative error (r < 0.73%) and cosine coefficient showed that the two methods obtained similar contents, and the method validations met the requirements. The results showed that QAMS can comprehensively and effectively control the quality of UFAs in Oviductus Ranae which provides new ideas and solutions for studying the active components in Oviductus Ranae.


Author(s):  
Ingrid Kästel ◽  
Giles de Quincey ◽  
Jörg Neugebauer ◽  
Robert Sader ◽  
Peter Gehrke

Abstract Background There is disagreement about the optimal torque for tightening smartpegs for resonance frequency analysis (RFA). Subjective finger pressure during hand tightening could affect the reliability of the resulting values. The aim of the current study was therefore to assess whether or not the insertion torque of a smartpeg magnetic device influences the implant stability quotient (ISQ) value during RFA. Methods Thirty self-tapping screw implants (XiVE S, Dentsply Sirona Implants, Bensheim, Germany) with a diameter of 3.8 mm and a length of 11 mm were inserted in three cow ribs with a bone quality of D1. The RFA value of each implant was measured (Ostell, FA W&H Dentalwerk, Bürmoos, Austria) in two orthogonal directions (mesial and buccal) after tightening the corresponding smartpeg type 45 with a mechanically defined value of 5 Ncm (Meg Torq device, Megagen, Daegu, South Korea) (test). Additionally, 4 different examiners measured the RFA after hand tightening the smartpegs, and the results were compared (control). Insertion torque values were determined by measuring the unscrew torque of hand seated smartpegs (Tohnichi Manufacturing Co. Ltd, Tokyo, Japan). Results The ISQ values varied from 2 to 11 Ncm by hand tightening and from 2 to 6 Ncm by machine tightening. The comparison of hand and machine tightening of smartpegs displayed only minor differences in the mean ISQ values with low standard deviations (mesial 79.76 ± 2,11, buccal 77.98 ± 2,) and no statistical difference (mesial p = 0,343 and buccal p = 0,890). Conclusions Manual tightening of smartpeg transducers allows for an objective and reliable determination of ISQ values during RFA.


Author(s):  
Akyıldız İsmail Emir ◽  
Yetimoğlu Kök Ece ◽  
Raday Sinem ◽  
Acar Sezer ◽  
Erdem Özge

Sign in / Sign up

Export Citation Format

Share Document