Detection of Genetically Modified Coho Salmon Using Polymerase Chain Reaction (PCR) Amplification

2002 ◽  
Vol 50 (11) ◽  
pp. 3161-3164 ◽  
Author(s):  
Saad Masri ◽  
Heidi Rast ◽  
Teresa Ripley ◽  
Delano James ◽  
Margaret Green ◽  
...  
2005 ◽  
Vol 88 (3) ◽  
pp. 814-822 ◽  
Author(s):  
Katarina Cankar ◽  
Maja Ravnikar ◽  
Jana Žel ◽  
Kristina Gruden ◽  
Nataša Toplak

Abstract Labeling of genetically modified organisms (GMOs) is now in place in many countries, including the European Union, in order to guarantee the consumer's choice between GM and non-GM products. Screening of samples is performed by polymerase chain reaction (PCR) amplification of regulatory sequences frequently introduced into genetically modified plants. Primers for the 35S promoter from Cauliflower mosaic virus (CaMV) are those most frequently used. In virus-infected plants or in samples contaminated with plant material carrying the virus, false-positive results can consequently occur. A system for real-time PCR using a TaqMan minor groove binder probe was designed that allows recognition of virus coat protein in the sample, thus allowing differentiation between transgenic and virus-infected samples. We measured the efficiency of PCR amplification, limits of detection and quantification, range of linearity, and repeatability of the assay in order to assess the applicability of the assay for routine analysis. The specificity of the detection system was tested on various virus isolates and plant species. All 8 CaMV isolates were successfully amplified using the designed system. No cross-reactivity was detected with DNA from 3 isolates of the closely related Carnation etched ring virus. Primers do not amplify plant DNA from available genetically modified maize and soybean lines or from different species of Brassicaceae or Solanaceae that are natural hosts for CaMV. We evaluated the assay for different food matrixes by spiking CaMV DNA into DNA from food samples and have successfully amplified CaMV from all samples. The assay was tested on rapeseed samples from routine GMO testing that were positive in the 35S screening assay, and the presence of the virus was confirmed.


2007 ◽  
Vol 42 (10) ◽  
pp. 1249-1255 ◽  
Author(s):  
Cibele dos Santos Ferrari ◽  
Luciana Lehmkuhl Valente ◽  
Fábio Cristiano Angonesi Brod ◽  
Caroline Tagliari ◽  
Ernani Sebastião Sant'Anna ◽  
...  

2004 ◽  
Vol 50 (6) ◽  
pp. 415-421 ◽  
Author(s):  
J Guan ◽  
J L Spencer ◽  
M Sampath ◽  
J Devenish

The fate of the genetically modified (GM) Pseudomonas chlororaphis strain 3732 RN-L11 and its transgene (lacZ insert) during composting of chicken manure was studied using plate count and nested polymerase chain reaction (PCR) methods. The detection sensitivity of the nested PCR method was 165 copies of the modified gene per gram of moist compost or soil. Compost microcosms consisted of a 100-g mixture of chicken manure and peat, whereas soil microcosms were 100-g samples of sandy clay loam. Each microcosm was inoculated with 4 × 1010CFU of P. chlororaphis RN-L11. In controlled temperature studies, neither P. chlororaphis RN-L11 nor its transgene could be detected in compost microcosms after incubation temperature was elevated to 45 °C or above for one or more days. In contrast, in the compost microcosms incubated at 23 °C, the target organism was not detected by the plate count method after 6 days, but its transgene was detectable for at least 45 days. In compost bins, the target organism was not recovered from compost microcosms or soil microcosms at different levels in the bins for 29 days. However, the transgene was detected in 8 of the 9 soil microcosms and in only 1 of the 9 compost microcosms. The compost microcosm in which transgene was detected was at the lower level of the bin where temperatures remained below 45 °C. The findings indicated that composting of organic wastes could be used to reduce or degrade heat sensitive GM microorganisms and their transgenes.Key words: composting, genetically modified Pseudomonas strain, transgene, polymerase chain reaction.


1996 ◽  
Vol 44 (10) ◽  
pp. 1205-1207 ◽  
Author(s):  
A Dakhama ◽  
V Macek ◽  
J C Hogg ◽  
R G Hegele

The polymerase chain reaction (PCR) is a powerful method that allows enzymatic amplification of rate target nucleic acid sequences. It has been applied to the amplification of viral genomes from paraffin-embedded pathology specimens. However, interpretation of negative results requires amplification of a housekeeping gene such as beta-actin. In the present study we used specific oligonucleotide primers previously designed to amplify both the genomic DNA and the mRNA transcript from paraffin-embedded tissue. These products have predicted sizes of 250 BP and 154 BP, respectively, but our results showed that PCR amplification only (without reverse transcription) unexpectedly generated the 154-BP product. Further investigation of the nature of this product demonstrated that it originated from the amplification of DNA, not RNA. We conclude that the 154-BP product generated by these primers cannot be exclusively considered as beta-actin RNA product and should not be used to assess successful extraction of RNA, to ascertain its integrity, or to normalize for the total amount of RNA assayed by RT-PCR from paraffin-embedded tissue.


2011 ◽  
Vol 27 (3) ◽  
pp. 357-364
Author(s):  
B. T. Chia ◽  
S.-A. Yang ◽  
M.-Y. Cheng ◽  
C.-W. Lin ◽  
Y.-J. Yang

ABSTRACTIn this paper, the development of a portable polymerase chain reaction (PCR) device is presented. Integrating electromagnetic mini-actuators for bi-directional fluid transport, the proposed device, whose dimension is 67mm × 66mm × 25mm, can be fully operated with a 5V DC voltage. The device consists of four major parts: A disposable channel chip in which PCR mixture is manipulated and reacted, a heater chip which generates different temperature zones for PCR reaction, a linear actuator array for pumping PCR mixture, and a circuit module for controlling and driving the system. The advantages of the device include the rapid temperature responses associated with continuous-flow-type PCR devices, as well as the programmable thermal cycling associated with chamber-type PCR devices. The thermal characteristics are measured and discussed. PCR amplification is successfully performed for the 122 bp segment of MCF-7/adr cell line. Due to its small footprint, this self-contained system potentially can be employed for point-of-care (POC) applications.