THE USE OF SCATTERED LIGHT IN THE DETERMINATION OF THE DISTRIBUTION OF SIZE OF PARTICLES IN EMULSIONS1

1925 ◽  
Vol 47 (6) ◽  
pp. 1582-1596 ◽  
Author(s):  
Alfred J. Stamm ◽  
The Svedberg
1974 ◽  
Vol 13 (6) ◽  
pp. 499-502
Author(s):  
I. V. Romanovich ◽  
B. N. Babich
Keyword(s):  

2013 ◽  
Vol 6 (3) ◽  
pp. 4123-4152 ◽  
Author(s):  
Y. Cai ◽  
J. R. Snider ◽  
P. Wechsler

Abstract. This work describes calibration methods for the particle sizing and particle concentration systems of the passive cavity aerosol spectrometer probe (PCASP). Laboratory calibrations conducted over six years, in support of the deployment of a PCASP on a cloud physics research aircraft, are analyzed. Instead of using the many calibration sizes recommended by the PCASP manufacturer, a relationship between particle diameter and scattered light intensity is established using three sizes of mobility-selected polystyrene latex particles, one for each amplifier gain stage. In addition, studies of two factors influencing the PCASP's determination of the particle size distribution – amplifier baseline and particle shape – are conducted. It is shown that the PCASP-derived size distribution is sensitive to adjustments of the sizing system's baseline voltage, and that for aggregate spheres, a PCASP-derived particle size and a sphere-equivalent particle size agree within uncertainty dictated by the PCASP's sizing resolution. Robust determination of aerosol concentration, and size distribution, also require calibration of the PCASP's aerosol flowrate sensor. Sensor calibrations, calibration drift, and the sensor's non-linear response are documented.


1980 ◽  
Vol 90 ◽  
pp. 55-60
Author(s):  
A. Mujica ◽  
G. Lôpez ◽  
F. Sánchez

SummaryA method of determination of the scattered light intensity, , by a unit-volume of interplanetary space is presented. From ground base Zodiacal Light measurements and the experimental results of Pioneer X the density, ρ(r), and phase, σ(θ), functions are obtained without any previous assumptions about them.


1977 ◽  
Vol 23 (8) ◽  
pp. 1456-1464 ◽  
Author(s):  
J C Sternberg

Abstract A kinetic nephelometric method and instrument have been developed for the rapid determination of specific serum proteins by means of immunoprecipitin reactions. The maximum rate of change of scattered light intensity in an antigen-antibody reaction can be made to occur within 60 s after initiation of the reaction and provides a measure of the antigen concentration under antibody excess conditions. A mathematical relationship has been found for the conversion of the nonlinear maximum rate data directly into a linear concentration read-out, making possible the use of single-point calibration. Instrument operating parameters and computations are programmed for a particular analysis by means of machine-readable cards. Antigen-excess samples are detected rapidly by injection of calibrator into the reaction mixture after the rate signal has dropped to a pre-selected level. The method correlates well with both radial immunodiffusion and end-point nephelometric methods.


Author(s):  
T. Okada ◽  
Y. Ishizu ◽  
K. Matsunuma

AbstractA new method for determining particle-size distribution of cigarette smoke particles was developed by simultaneous measurement of scattered light at three angles for a fixed wavelength. A theoretical chart useful for this purpose, which was made of the relative intensities of scattered light at the angles 45° and 135° to that at the angle 90°, was calculated on the basis of the Mie theory. The number concentration was determined from the Rayleigh ratio using the working standard method. The measurements were rapidly performed, without change of particle size during measuring time, with a device for dilution. The geometric mean diameter, the logarithmic standard deviation and the number concentration of mainstream smoke were found to be about 0.18 um, 0.4 and 3 X 10


1977 ◽  
Vol 1977 (1) ◽  
pp. 153-156 ◽  
Author(s):  
Bruce Friedman

ABSTRACT Light scattering techniques are used in several oil-in-water monitors, proposed or in existence. Particulate matter which may interfere with these monitors is also frequently found in oily wastes. An analysis is made of the potential of using measurements of the angular intensity distribution of scattered light in conjunction with determination of the state of polarization of the scattered light for discriminating between oil and particulates. The size conditions which apply to the oil droplets and particulates relative to the incident light allow the scattered light angular intensity distribution to be treated as a consequence of a combination of classical diffraction and of geometrical refraction and reflection. The state of polarization of the scattered light for oil droplets is investigated using expressions for the electric field which are approximations to the expressions of the Mie theory. For the particulate matter, the state of polarization is probed on the basis of light reflected from a plane. It is found that it would be difficult to discriminate between oil and particulates using measurements of the angular intensity distribution of scattered light even in conjunction with the determination of the state of polarization of the scattered light in a real life situation.


Sign in / Sign up

Export Citation Format

Share Document