Electrochemical Oxidation of Refractory Organics in the Coking Wastewater and Chemical Oxygen Demand (COD) Removal under Extremely Mild Conditions

2008 ◽  
Vol 47 (21) ◽  
pp. 8478-8483 ◽  
Author(s):  
Bo Wang ◽  
Xin Chang ◽  
Hongzhu Ma
Water ◽  
2020 ◽  
Vol 12 (9) ◽  
pp. 2532
Author(s):  
Can He ◽  
Jianbing Wang ◽  
Heng Xu ◽  
Xiangyu Ji ◽  
Weiyi Wang ◽  
...  

In this work, the treatment of bio-treated coking wastewater (BCW) by catalytic ozonation was conducted in semi-batch and continuous flow reactors. The kinetics of chemical oxygen demand (COD) removal were analyzed using BCWs from five coking plants. An integral reactor with catalytic ozonation stacked by ozone absorption (IR) was developed, and its efficiency was studied. The catalyst of MnxCe1-xO2/γ-Al2O3 was efficient in the catalytic ozonation process for the treatment of various BCWs. The chemical oxygen demand (COD) removal efficiencies after 120 min reaction were 64–74%. The overall apparent reaction rate constants were 0.0101–0.0117 min−1, which has no obvious relationship with the initial COD of BCW and pre-treatment biological process. The IR demonstrated the highest efficiency due to the enhancement of mass transfer and the utilization efficiency of ozone. Bypass internal circulation can further improve the reactor efficiency. The optimal results were obtained with the ozone absorption section accounting for 19% of the valid water depth in the reactor and 250% of circulation flow ratio. The long-term and full-scale application of the novel reactor in a continuous mode indicated stable removal of COD and polycyclic aromatic hydrocarbons (PAHs). The results showed that the system of IR is a promising reactor type for tertiary treatment of coking wastewater by catalytic ozonation.


2019 ◽  
Vol 180 ◽  
pp. 105199 ◽  
Author(s):  
Ziqi Zhou ◽  
Tian Yu ◽  
Hailiang Dong ◽  
Liuqin Huang ◽  
Rosalie K. Chu ◽  
...  

2013 ◽  
Vol 2013 ◽  
pp. 1-8 ◽  
Author(s):  
Ali Jalilzadeh ◽  
Ramin Nabizadeh ◽  
Alireza Mesdaghinia ◽  
Aliakbar Azimi ◽  
Simin Nasseri ◽  
...  

A systematic model for chemical oxygen demand (COD) removal using the ANAMMOX (Anaerobic AMMonium OXidation) process was provided based on an experimental design. At first, the experimental data was collected from a combined biological aerobic/anaerobic reactor. For modelling and optimization of COD removal, the main parameters were considered, such as COD loading, ammonium, pH, and temperature. From the models, the optimum conditions were determined as COD 97.5 mg/L, ammonium concentration equal to 28.75 mg-N/L, pH 7.72, and temperature 31.3°C. Finally, the analysis of the optimum conditions, performed by the response surface method, predicted COD removal efficiency of 81.07% at the optimum condition.


Processes ◽  
2019 ◽  
Vol 7 (7) ◽  
pp. 418 ◽  
Author(s):  
Pedro Cisterna-Osorio ◽  
Verónica Lazcano-Castro ◽  
Gisela Silva-Vasquez ◽  
Mauricio Llanos-Baeza ◽  
Ignacio Fuentes-Ortega

The objective of this work is to evaluate the impact of innovative modifications made to conventional effluent capture and discharge devices used in subsurface flow wetlands (SSFW). The main modifications that have been developed extend the influence of the capture and discharge device in such a way that the SSFW width and height are fully covered. This improved innovative device was applied and evaluated in two subsurface flow wetlands, one on a pilot scale and one on a real scale. To evaluate the impact of the innovative device with respect to the conventional one in the operational functioning of subsurface flow wetlands, the elimination of chemical oxygen demand (COD) was measured and compared. The results show that for the innovative device, the COD removal was 10% higher than for the conventional device, confirming the validity and effectiveness of the modifications implemented in the effluent capture and discharge devices used in SSFW.


2020 ◽  
Vol 49 (1) ◽  
pp. 46-54 ◽  
Author(s):  
Wei Zhang ◽  
Weiwei Lv ◽  
Xiaoyan Li ◽  
Jiming Yao

Purpose In this study, the oxidative degradation performance of indigo wastewater based on electrochemical systems was explored. The decolourization degrees, removal rate of chemical oxygen demand and biochemical oxygen demand of the indigo wastewater after degradation were evaluated and optimized treatment conditions being obtained. Design/methodology/approach The single factor method was first used to select the electrolyte system and electrode materials. Then the response surface analysis based on Box–Behnken Design was chosen to determine the influence of four independent variables such as FeCl3 concentration, NaCl concentration, decolourization time and voltage on the degradation efficiency. Findings On the basis of single factor experiment, the electrode material of stainless steel was selected in the double cell, and the indigo wastewater was electrolyzed with FeCl3 and NaCl electrolytes. The process conditions of electrochemical degradation of indigo wastewater were optimized by response surface analysis: the concentration of FeCl3 and NaCl was of 16 and 9 g/L, respectively, with a decolourization time of 50 min, voltage of 10 V and decolourization percentage of 98.94. The maximum removal rate of chemical oxygen demand reached 75.46 per cent. The highest ratio of B/C was 3.77, which was considered to be more biodegradable. Research limitations/implications Dyeing wastewater is bringing out more and more pollution problems to the environment. However, there are some shortcomings in traditional technologies such as adsorption and filtration. As a kind of efficient and clean water treatment technology, electrochemical oxidation has been applied to the treatments of various types of wastewater. The decolourization and degradation of indigo wastewater is taken as an example to provide reference for the treatment of wastewater in actual plants. Practical implications The developed method provided a simple and practical solution for efficiently degrading indigo wastewater. Originality/value The method for the electrochemical oxidation technology was novel and could find numerous applications in the degradation of printing and dyeing wastewater.


2013 ◽  
Vol 68 (1) ◽  
pp. 257-260 ◽  
Author(s):  
Yujie Feng ◽  
Junfeng Liu ◽  
Limin Zhu ◽  
Jinzhi Wei

The clomazone herbicide wastewater was treated using a combined technology composed of electrochemical catalytic oxidation and biological contact degradation. A new type of electrochemical reactor was fabricated and a Ti/SnO2 electrode was chosen as the anode in electrochemical-oxidation reactor and stainless steel as the cathode. Ceramic rings loaded with SnO2 were used as three-dimensional electrodes forming a packed bed. The operation parameters that might influence the degradation of organic contaminants in the clomazone wastewater were optimized. When the cell voltage was set at 30 V and the volume of particle electrodes was designed as two-thirds of the volume of the total reactor bed, the chemical oxygen demand (COD) removal rate could reach 82% after 120 min electrolysis, and the ratio of biochemical oxygen demand (BOD)/COD of wastewater increased from 0.12 to 0.38. After 12 h degradation with biological contact oxidation, the total COD removal rate of the combined technology reached 95%, and effluent COD was below 120 mg/L. The results demonstrated that this electrocatalytic oxidation method can be used as a pretreatment for refractory organic wastewater before biological treatment.


2010 ◽  
Vol 62 (11) ◽  
pp. 2669-2677 ◽  
Author(s):  
Lizhang Wang ◽  
Yuemin Zhao

Experiments were performed to reduce chemical oxygen demand (COD) from 4,4′-diaminostilbene-2,2′-disulfonic (DSD) acid manufacturing wastewater using electrochemical oxidation coupled with adsorption by granular activated carbon. The COD removal is affected by the residence time and applied voltage. When the residence time is increased, lower value of COD effluent could be obtained, however, the average current efficiency (ACE) decreased rapidly, and so does the applied voltage. In addition, aeration could effectively enhance COD removal efficiency and protect anodes from corrosion. Furthermore, the acidic condition is beneficial to the rapid decrease of COD and the values of pH effluent are independent of the initial solution pH. The optimization conditions obtained from these experiments are applied voltage of 4.8 V, residence time of 180 min and air–liquid ratio of 4.2 with the COD effluent of about 690 mg L−1. In these cases, the ACE and energy consumption are 388% and 4.144 kW h kg−1 COD, respectively. These perfect results from the experiments illustrate that the combined process is a considerable alternative for the treatment of industrial wastewater containing high concentration of organic pollutants and salinity.


Molecules ◽  
2019 ◽  
Vol 24 (24) ◽  
pp. 4436 ◽  
Author(s):  
Zhiyong Yang ◽  
Penglei Wang ◽  
Yagang Zhang ◽  
Xingjie Zan ◽  
Wenjuan Zhu ◽  
...  

Polymerization mother liquid (PML) is one of the main sources of wastewater in the chlor-alkali industry. The effective degradation of the PML produced in PVC polymerization using three or five ozone reactors in tandem was designed with a focus on improving the ozonation efficiency. The ozonation efficiency of the tandem reactors for the degradation of PML, along with the effect of ozone concentration, the number of reactors utilized in series, and the reaction time on the chemical oxygen demand (COD) removal were investigated in detail. The results showed that the COD removal increased as the ozone concentration was increased from 10.6 to 60 mg·L−1, achieving 66.4% COD removal at ozone concentration of 80.6 mg·L−1. However, when the ozone concentration was increased from 60 mg·L−1 to 80 mg·L−1, the COD removal only increased very little. The COD decreased with increasing ozone concentration. During the initial degradation period, the degradation rate was the highest at both low and high ozone concentrations. The degradation rate decreased with reaction time. The rate at a low ozone concentration decreased more significantly than at high ozone concentration. Although high ozone concentration is desirable for COD removal and degradation rate, the utilization efficiency of ozone decreased with increasing ozone concentration. The ozone utilization efficiency of the five-reactor device was three times higher than that of three tandem reactors, demonstrating that ozonation utilization efficiency can be improved by increasing the number of tandem reactors. Ozonation in tandem reactors is a promising approach for PML treatment.


Sign in / Sign up

Export Citation Format

Share Document