Analysis of Perchlorate in Human Saliva by Liquid Chromatography−Tandem Mass Spectrometry

2009 ◽  
Vol 43 (1) ◽  
pp. 142-147 ◽  
Author(s):  
John F. Oldi ◽  
Kurunthachalam Kannan
2019 ◽  
Vol 2019 ◽  
pp. 1-8 ◽  
Author(s):  
Syed N. Alvi ◽  
Muhammad M. Hammami

A simple ultraperformance liquid chromatography-tandem mass spectrometry assay for measurement of cortisol level in human saliva was developed and validated. Saliva samples containing cortisol were spiked with tolperisone as internal standard (IS) and extracted with a mixture of methyl tert-butyl ether and hexane (8:2, v:v). After solvent evaporation, residue was reconstituted in 100 μl mobile phase. Analysis was performed on Atlantis dC18 column (2.1 × 100 mm, 3 μm particle size) with a mobile phase composed of acetonitrile and 2 mM ammonium acetate (50:50, v:v) and delivered at a flow rate of 0.3 ml/minute. Mass spectrometry acquisition was performed with multiple reaction monitoring in positive-ion mode for cortisol and IS (m/z: 363.1 → 121.0 and 246.0 → 97.9, respectively). Retention times of cortisol and IS were about 1.35 and 2.45 minutes, respectively. The relationship between cortisol level and peak area ratio of cortisol to IS was linear in the range of 0.5-100 ng/ml. Intra- and interday coefficient of variation and bias were ≤ 9.0% and ≤12.0%, respectively. Mean extraction recoveries of cortisol and IS from saliva samples were 92% and 94%, respectively. Using the method, cortisol was found to be ≥ 86% stable in processed (24 hours at room temperature or 48 hours at -20°C) and ≥ 91% stable in unprocessed (24 hours at room temperature or 20 weeks at -20°C) saliva samples. Further, the method was successfully applied to determine daily cortisol profile in saliva samples of a healthy volunteer.


Molecules ◽  
2019 ◽  
Vol 24 (7) ◽  
pp. 1191 ◽  
Author(s):  
Zeynab Zohdi ◽  
Mahdi Hashemi ◽  
Abdusalam Uheida ◽  
Mohammad Moein ◽  
Mohamed Abdel-Rehim

In this study, a novel sort of sample preparation sorbent was developed, by preparing thin layer graphene oxide tablets (GO-Tabs) utilizing a mixture of graphene oxide and polyethylene glycol on a polyethylene substrate. The GO-Tabs were used for extraction and concentration of omeprazole (OME) in human saliva samples. The determination of OME was carried out using liquid chromatography-tandem mass spectrometry (LC–MS/MS) under gradient LC conditions and in the positive ion mode (ESI+) with mass transitions of m/z 346.3→198.0 for OME and m/z 369.98→252.0 for the internal standard. Standard calibration for the saliva samples was in the range of 2.0–2000 nmol L−1. Limits of detection and quantification were 0.05 and 2.0 nmol L−1, respectively. Method validation showed good method accuracy and precision; the inter-day precision values ranged from 5.7 to 8.3 (%RSD), and the accuracy of determinations varied from −11.8% to 13.3% (% deviation from nominal values). The extraction recovery was 60%, and GO-Tabs could be re-used for more than ten extractions without deterioration in recovery. In this study, the determination of OME in real human saliva samples using GO-Tab extraction was validated.


Sign in / Sign up

Export Citation Format

Share Document