High energy resolution x-ray photoelectron spectroscopy studies of tetracyanoquinodimethane charge transfer complexes with copper, nickel, and lithium

1989 ◽  
Vol 1 (1) ◽  
pp. 72-78 ◽  
Author(s):  
John M. Lindquist ◽  
John C. Hemminger
2020 ◽  
Vol 22 (26) ◽  
pp. 14731-14735
Author(s):  
Anna Wach ◽  
Wojciech Błachucki ◽  
Joanna Czapla-Masztafiak ◽  
Daniel Luis Abreu Fernandes ◽  
Dariusz Banaś ◽  
...  

In this paper, we demonstrated how high energy resolution resonant X-ray emission spectroscopy can be employed to study the charge transfer dynamics in real-time during the temperature-induced oxidation of metallic tungsten.


1998 ◽  
Vol 5 (3) ◽  
pp. 1111-1113 ◽  
Author(s):  
Takanori Kiyokura ◽  
Fumihiko Maeda ◽  
Yoshio Watanabe ◽  
Eiji Shigemasa ◽  
Akira Yagishita ◽  
...  

A submicrometre-area photoelectron spectroscopy system that uses a multi-layer-coated Schwarzschild objective as the soft X-ray microbeam optics has been developed. The system is located at an undulator beamline (BL-16U) at the Photon Factory in the High Energy Accelerator Research Organization. By knife-edge measurement, the microbeam size was estimated to be 160 nm at the sample position using a 25–75% criterion. Photoelectron spectral measurements revealed that the Fermi edge width was 0.12 eV, which means that the instrumental resolution was 0.05 eV, after removing the natural broadening of the Fermi edge at room temperature. This system offers both high energy resolution and high spatial resolution.


1991 ◽  
Vol 4 (3) ◽  
pp. 18-19 ◽  
Author(s):  
Eugen Weschke ◽  
Clemens Laubschat ◽  
Thomas Simmons ◽  
Michael Domke ◽  
Gunter Kaindl

2020 ◽  
Vol 27 (1) ◽  
pp. 238-249 ◽  
Author(s):  
Christian Schulz ◽  
Klaus Lieutenant ◽  
Jie Xiao ◽  
Tommy Hofmann ◽  
Deniz Wong ◽  
...  

The performance of the recently commissioned spectrometer PEAXIS for resonant inelastic soft X-ray scattering (RIXS) and X-ray photoelectron spectroscopy and its hosting beamline U41-PEAXIS at the BESSY II synchrotron are characterized. The beamline provides linearly polarized light from 180 eV to 1600 eV allowing for RIXS measurements in the range 200–1200 eV. The monochromator optics can be operated in different configurations to provide either high flux with up to 1012 photons s−1 within the focal spot at the sample or high energy resolution with a full width at half maximum of <40 meV at an incident photon energy of ∼400 eV. The measured total energy resolution of the RIXS spectrometer is in very good agreement with theoretically predicted values obtained by ray-tracing simulations. PEAXIS features a 5 m-long RIXS spectrometer arm that can be continuously rotated about the sample position by 106° within the horizontal photon scattering plane, thus enabling the study of momentum-transfer-dependent excitations. Selected scientific examples are presented to demonstrate the instrument capabilities, including measurements of excitations in single-crystalline NiO and in liquid acetone employing a fluid cell sample manipulator. Planned upgrades of the beamline and the RIXS spectrometer to further increase the energy resolution to ∼100 meV at 1000 eV incident photon energy are discussed.


2019 ◽  
Vol 21 (33) ◽  
pp. 18363-18369 ◽  
Author(s):  
Daisuke Asakura ◽  
Yusuke Nanba ◽  
Eiji Hosono ◽  
Masashi Okubo ◽  
Hideharu Niwa ◽  
...  

High-energy-resolution soft X-ray emission spectroscopy (XES) was applied to understand the changes in the electronic structure of LiMn2O4 upon Li-ion extraction/insertion.


2015 ◽  
Vol 51 (48) ◽  
pp. 9864-9867 ◽  
Author(s):  
Richard C. Walroth ◽  
Jacob W. H. Uebler ◽  
Kyle M. Lancaster

CuI X-ray absorption features are assigned as metal-to-ligand charge transfer bands. These features facilitate species identification in catalytic reaction mixtures.


Sign in / Sign up

Export Citation Format

Share Document