Revealing the Viscosity Changes in Lipid Droplets during Ferroptosis by the Real-Time and In Situ Near-Infrared Imaging

ACS Sensors ◽  
2020 ◽  
Author(s):  
Baoli Dong ◽  
Wenhui Song ◽  
Yaru Lu ◽  
Yaru Sun ◽  
Weiying Lin
2017 ◽  
Vol T170 ◽  
pp. 014027 ◽  
Author(s):  
A Huber ◽  
D Kinna ◽  
V Huber ◽  
G Arnoux ◽  
I Balboa ◽  
...  

2021 ◽  
pp. 130747
Author(s):  
Yanyan Ma ◽  
Yongyuan Liu ◽  
Zike Jiang ◽  
Hongmin Lv ◽  
Jing Wang ◽  
...  

2020 ◽  
Vol 12 (19) ◽  
pp. 3211
Author(s):  
Xiaobin Qi ◽  
Zongcheng Ling ◽  
Jiang Zhang ◽  
Jian Chen ◽  
Haijun Cao ◽  
...  

Until 29 May 2020, the Visible and Near-Infrared Imaging Spectrometer (VNIS) onboard the Yutu-2 Rover of the Chang’e-4 (CE-4) has acquired 96 high-resolution surface in-situ imaging spectra. These spectra were acquired under different illumination conditions, thus photometric normalization should be conducted to correct the introduced albedo differences before deriving the quantitative mineralogy for accurate geologic interpretations. In this study, a Lommel–Seeliger (LS) model and Hapke radiative transfer (Hapke) model were used and empirical phase functions of the LS model were derived. The values of these derived phase functions exhibit declining trends with the increase in phase angles and the opposition effect and phase reddening effect were observed. Then, we discovered from in-situ and laboratory measurements that the shadows caused by surface roughness have significant impacts on reflectance spectra and proper corrections were introduced. The validations of different phase functions showed that the maximum discrepancy at 1500 nm of spectra corrected by the LS model was less (~3.7%) than that by the Hapke model (~7.4%). This is the first time that empirical phase functions have been derived for a wavelength from 450 to 2395 nm using in-situ visible and near-infrared spectral datasets. Generally, photometrically normalized spectra exhibit smaller spectral slopes, lower FeO contents and larger optical maturity parameter (OMAT) than spectra without correction. In addition, the band centers of the 1 and 2 μm absorption features of spectra after photometric normalization exhibit a more concentrated distribution, indicating the compositional homogeneity of soils at the CE-4 landing site.


Neurosurgery ◽  
2019 ◽  
Vol 66 (Supplement_1) ◽  
Author(s):  
Steve Sungwon Cho ◽  
Ashwin G Ramayya ◽  
Clare W Teng ◽  
Steven Brem ◽  
Sunil Singhal ◽  
...  

Abstract INTRODUCTION Neuronavigation allows neurosurgeons to localize intracranial structures in 3D space and has been shown to have positive impacts on patient survival in neuro-oncology surgery. However, its major limitation is the intraoperative brain-shift phenomenon, in which the brain moves during surgery due to physical, surgical, and/or biological factors, invalidating the preoperative registration and leading to inaccuracies in the cranium. One reliable way to account for brain-shift intraoperatively may be to use tumor-targeting near-infrared fluorophores, such as ICG accumulating in neoplastic tissue (ie, Second-Window ICG), which offers real-time visualization of tumors through normal cortex and dura. METHODS Patients undergoing craniotomy for primary resection of intracranial tumors were enrolled under an ongoing clinical trial investigating the efficacy of SWIG. For this analysis, retrospective data were collected on patients in whom neuronavigation was used to plan the craniotomy in such a way as to place the tumor in the center of the craniotomy (ie, parasagittal tumors, skull-base tumors, and large/asymmetrical tumors were excluded). During surgery, near-infrared imaging was performed before and after durotomy to localize the gross tumor. Image analysis was performed to measure the deviation between the craniotomy center and the center of the tumor as seen with near-infrared fluorescence. RESULTS A total of 63 patients (24 high-grade-gliomas, 12 meningiomas, 25 metastases, 2 others) were included in this preliminary analysis. Neuronavigation demonstrated a median deviation of 22.4% (range 7.7%-44.4%) relative to craniotomy size. Patient position was a significant predictor of neuronavigation inaccuracy, with the prone position having significantly higher inaccuracy (28.5 ± 8.8%) compared to the supine (19.3 ± 9.2%, P-value = .015) or the lateral (17.9 ± 6.6%, P-value = .012) positions. Additionally, the neuronavigation device used and postgraduate training level of the residents performing the registration trended towards significance on multivariate analysis. In contrast, near-infrared fluorescence perfectly delineated the tumor in all cases. CONCLUSION We demonstrate that near-infrared fluorescence imaging offers more accurate localization of intracranial tumors compared to frameless neuronavigation. Near-infrared imaging could potentially be used to adjust neuronavigation registrations intraoperatively to enhance accuracy. Further prospective studies with distance measurements could better explore this potential benefit of intraoperative near-infrared imaging.


2014 ◽  
Vol 2 (4) ◽  
pp. 180-183 ◽  
Author(s):  
Yasuyuki Mitani ◽  
Akio Kubota ◽  
Masaki Ueno ◽  
Katsunari Takifuji ◽  
Takashi Watanabe ◽  
...  

2018 ◽  
Vol 143 (9) ◽  
pp. 1076-1083 ◽  
Author(s):  
Suzanne M. Dintzis ◽  
Stacey Hansen ◽  
Kristi M. Harrington ◽  
Lennart C. Tan ◽  
Dennis M. Miller ◽  
...  

Context.— Resection of breast carcinoma with adequate margins reduces the risk of local recurrence and reoperation. Tozuleristide (BLZ-100) is an investigational peptide-fluorophore agent that may aid in intraoperative tumor detection and margin assessment. In this study, fluorescence imaging was conducted ex vivo on gross breast pathology specimens. Objectives.— To determine the potential of tozuleristide to detect breast carcinoma in fresh pathology specimens and the feasibility of fluorescence-guided intraoperative pathology assessment of surgical margins. Design.— Twenty-three patients received an intravenous bolus dose of 6 or 12 mg of tozuleristide at least 1 hour before surgery. Fifteen lumpectomy and 12 mastectomy specimens were evaluated for fluorescence by the site's clinical pathology staff using the SIRIS, an investigational near-infrared imaging device. The breast tissue was then processed per usual procedures. Fluorescent patterns were correlated with the corresponding hematoxylin-eosin–stained sections. Clinical pathology reports were used to correlate fluorescent signal to grade, histotype, prognostic marker status, and margin measurements. Results.— Tozuleristide fluorescence was readily observed in invasive and in situ breast carcinoma specimens. Most invasive carcinomas were bright and focal, whereas in situ lesions demonstrated a less intense, more diffuse pattern. Tozuleristide was detected in ductal and lobular carcinomas with a similar fluorescent pattern. Fluorescence was detected in high- and low-grade lesions, and molecular marker/hormone receptor status did not affect signal. Fluorescence could be used to identify the relationship of carcinoma to margins intraoperatively. Conclusions.— Tumor targeting with tozuleristide allowed visual real-time distinction between pathologically confirmed breast carcinoma and normal tissue.


2021 ◽  
Vol 13 (12) ◽  
pp. 2359
Author(s):  
Jiafei Xu ◽  
Meizhu Wang ◽  
Rong Wang ◽  
Qi Feng ◽  
Honglei Lin ◽  
...  

In-situ measurements of the spectral information on the lunar surface are of significance to study the geological evolution of the Moon. China’s Chang’E-4 (CE-4) Yutu-2 rover has conducted several in-situ spectral explorations on the Moon. The visible and near-infrared imaging spectrometer (VNIS) onboard the rover has acquired a series of in-situ spectra of the regolith at the landing site. In general, the mineralogical research of the lunar surface relies on the accuracy of the in-situ data. However, the spectral measurements of the Yutu-2 rover may be affected by shadows and stray illumination. In this study, we analyzed 106 CE-4 VNIS spectra acquired in the first 24 lunar days of the mission and noted that six of these spectra were affected by the shadows of the rover. Therefore, a method was established to correct the effects of the rover shadow on the spectral measurements. After shadow correction, the FeO content in the affected area is corrected to 14.46 wt.%, which was similar to the result calculated in the normal regolith. Furthermore, according to the visible images, certain areas of the explored sites were noted to be unusually bright. Considering the reflectance, geometric information, and shining patterns of the multi-layer insulation (MLI), we examined the influence of the specular reflection of the MLI on the bright spot regionsd , and found that the five sets of data were likely not affected by the specular reflection of the MLI. The results indicated that the complex illumination considerably influences the in situ spectral data. This study can provide a basis to analyze the VNIS scientific data and help enhance the accuracy of interpretation of the composition at CE-4 landing sites.


2015 ◽  
Vol 493 (1-2) ◽  
pp. 198-207 ◽  
Author(s):  
Patrick S. Wray ◽  
Wayne E. Sinclair ◽  
John W. Jones ◽  
Graham S. Clarke ◽  
Douglas Both

Sign in / Sign up

Export Citation Format

Share Document