scholarly journals Cellular Shuttles: Monocytes/Macrophages Exhibit Transendothelial Transport of Nanoparticles under Physiological Flow

2017 ◽  
Vol 9 (22) ◽  
pp. 18501-18511 ◽  
Author(s):  
Thomas L. Moore ◽  
Daniel Hauser ◽  
Thomas Gruber ◽  
Barbara Rothen-Rutishauser ◽  
Marco Lattuada ◽  
...  
2018 ◽  
Vol 14 (6) ◽  
pp. 481-502 ◽  
Author(s):  
Anber Saleem ◽  
Sadia Waheed ◽  
Sohail Nadeem

2000 ◽  
Author(s):  
Hai-Chao Han ◽  
Raymond P. Vito ◽  
Kristin Michael ◽  
David N. Ku

Abstract To study the effect of axial stretch on vascular function and wall remodeling, porcine carotid arteries were cultured under conditions of physiological flow and elevated axial stretch in an ex vivo organ culture system. Smooth muscle cell proliferation was measured by bromodeoxyuridine index. Results showed that cell proliferation was significantly increased in the highly stretched arteries when compared to the normally stretched arteries. This may indicate the feasibility of stimulating new arterial growth by stretching natural arteries.


2020 ◽  
pp. 1-8 ◽  
Author(s):  
Adithya S. Reddy ◽  
Yang Liu ◽  
Joshua Cockrum ◽  
Daniel Gebrezgiabhier ◽  
Evan Davis ◽  
...  

OBJECTIVEThe development of new endovascular technologies and techniques for mechanical thrombectomy in stroke has greatly relied on benchtop simulators. This paper presents an affordable, versatile, and realistic benchtop simulation model for stroke.METHODSA test bed for embolic occlusion of cerebrovascular arteries and mechanical thrombectomy was developed with 3D-printed and commercially available cerebrovascular phantoms, a customized hydraulic system to generate physiological flow rate and pressure, and 2 types of embolus analogs (elastic and fragment-prone) capable of causing embolic occlusions under physiological flow.RESULTSThe test bed was highly versatile and allowed realistic, radiation-free mechanical thrombectomy for stroke due to large-vessel occlusion with rapid exchange of geometries and phantom types. Of the transparent cerebrovascular phantoms tested, the 3D-printed phantom was the easiest to manufacture, the glass model offered the best visibility of the interaction between embolus and thrombectomy device, and the flexible model most accurately mimicked the endovascular system during device navigation. None of the phantoms modeled branches smaller than 1 mm or perforating arteries, and none underwent realistic deformation or luminal collapse from device manipulation or vacuum. The hydraulic system created physiological flow rate and pressure leading to iatrogenic embolization during thrombectomy in all phantoms. Embolus analogs with known fabrication technique, structure, and tensile strength were introduced and consistently occluded the middle cerebral artery bifurcation under physiological flow, and their interaction with the device was accurately visualized.CONCLUSIONSThe test bed presented in this study is a low-cost, comprehensive, realistic, and versatile platform that enabled high-quality analysis of embolus–device interaction in multiple cerebrovascular phantoms and embolus analogs.


2020 ◽  
Vol 44 (8) ◽  
pp. 818-826
Author(s):  
Albert Chong ◽  
Zhonghua Sun ◽  
Lennart van de Velde ◽  
Shirley Jansen ◽  
Michel Versluis ◽  
...  

2020 ◽  
Vol 61 (12) ◽  
Author(s):  
Sanjiv Gunasekera ◽  
Olivia Ng ◽  
Shannon Thomas ◽  
Ramon Varcoe ◽  
Charitha de Silva ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document