Distributed Feedback Lasing in Amorphous Polymers with Covalently Bonded Fluorescent Dyes: The Influence of Photoisomerization Process

2017 ◽  
Vol 50 (16) ◽  
pp. 6164-6173 ◽  
Author(s):  
Kacper Parafiniuk ◽  
Cyrille Monnereau ◽  
Lech Sznitko ◽  
Bastien Mettra ◽  
Monika Zelechowska ◽  
...  
Author(s):  
M. Boublik ◽  
W. Hellmann ◽  
F. Jenkins

The present knowledge of the three-dimensional structure of ribosomes is far too limited to enable a complete understanding of the various roles which ribosomes play in protein biosynthesis. The spatial arrangement of proteins and ribonuclec acids in ribosomes can be analysed in many ways. Determination of binding sites for individual proteins on ribonuclec acid and locations of the mutual positions of proteins on the ribosome using labeling with fluorescent dyes, cross-linking reagents, neutron-diffraction or antibodies against ribosomal proteins seem to be most successful approaches. Structure and function of ribosomes can be correlated be depleting the complete ribosomes of some proteins to the functionally inactive core and by subsequent partial reconstitution in order to regain active ribosomal particles.


Author(s):  
W.A. Carrington ◽  
F.S. Fay ◽  
K.E. Fogarty ◽  
L. Lifshitz

Advances in digital imaging microscopy and in the synthesis of fluorescent dyes allow the determination of 3D distribution of specific proteins, ions, GNA or DNA in single living cells. Effective use of this technology requires a combination of optical and computer hardware and software for image restoration, feature extraction and computer graphics.The digital imaging microscope consists of a conventional epifluorescence microscope with computer controlled focus, excitation and emission wavelength and duration of excitation. Images are recorded with a cooled (-80°C) CCD. 3D images are obtained as a series of optical sections at .25 - .5 μm intervals.A conventional microscope has substantial blurring along its optical axis. Out of focus contributions to a single optical section cause low contrast and flare; details are poorly resolved along the optical axis. We have developed new computer algorithms for reversing these distortions. These image restoration techniques and scanning confocal microscopes yield significantly better images; the results from the two are comparable.


Author(s):  
Rudolf Oldenbourg

The recent renaissance of the light microsope is fueled in part by technological advances in components on the periphery of the microscope, such as the laser as illumination source, electronic image recording (video), computer assisted image analysis and the biochemistry of fluorescent dyes for labeling specimens. After great progress in these peripheral parts, it seems timely to examine the optics itself and ask how progress in the periphery facilitates the use of new optical components and of new optical designs inside the microscope. Some results of this fruitful reflection are presented in this symposium.We have considered the polarized light microscope, and developed a design that replaces the traditional compensator, typically a birefringent crystal plate, with a precision universal compensator made of two liquid crystal variable retarders. A video camera and digital image processing system provide fast measurements of specimen anisotropy (retardance magnitude and azimuth) at ALL POINTS of the image forming the field of view. The images document fine structural and molecular organization within a thin optical section of the specimen.


Author(s):  
Anne M. Klinkner ◽  
Crystal R. Waites ◽  
Peter J. Bugelski ◽  
William D. Kerns

A primary effort in the understanding of the progression of atherosclerotic disease has been methods development for visualization of the atherosclerotic plaque. We introduce a new method for the qualitative analysis of lipids in atherosclerotic fatty streaks which also retains those lipids for biochemical evaluation. An original aspect of the process is the ability to view an entire fatty streak en face, selectively stained for specific lipid classes within the lesion.New Zealand white rabbits were fed a high cholesterol diet(0.15%-0.3% for 14 wks). The aorta was removed and fixed in Carson's phosphate buffered formaldehyde followed by dual staining in the fluorescent dyes Nile red and filipin. Stock solutions of nile red(0.5mg/ml acetone) and filipin(2.5mg/ml dimethyl formamide) were prepared and kept at -20°C; all subsequent steps were at RT. 0.5cm × 1.0cm pieces of aorta were trimmed and adventitia removed. The pieces were then washed 3×15 min in PBS w/o CaMg, soaked in Nile red(NR)/filipin(Fl) stain(100(il NR stock + 200μl Fl stock in 10 ml PBS for 30 min, washed in PBS 3×30 min, rinsed with distilled water, mounted(Crystal Mount, Biomedia) and coverslipped and viewed by fluorescence microscopy.


Author(s):  
Richard J. Spontak ◽  
Steven D. Smith ◽  
Arman Ashraf

Block copolymers are composed of sequences of dissimilar chemical moieties covalently bonded together. If the block lengths of each component are sufficiently long and the blocks are thermodynamically incompatible, these materials are capable of undergoing microphase separation, a weak first-order phase transition which results in the formation of an ordered microstructural network. Most efforts designed to elucidate the phase and configurational behavior in these copolymers have focused on the simple AB and ABA designs. Few studies have thus far targeted the perfectly-alternating multiblock (AB)n architecture. In this work, two series of neat (AB)n copolymers have been synthesized from styrene and isoprene monomers at a composition of 50 wt% polystyrene (PS). In Set I, the total molecular weight is held constant while the number of AB block pairs (n) is increased from one to four (which results in shorter blocks). Set II consists of materials in which the block lengths are held constant and n is varied again from one to four (which results in longer chains). Transmission electron microscopy (TEM) has been employed here to investigate the morphologies and phase behavior of these materials and their blends.


Author(s):  
S.D. Smith ◽  
R.J. Spontak ◽  
D.H. Melik ◽  
S.M. Buehler ◽  
K.M. Kerr ◽  
...  

When blended together, homopolymers A and B will normally macrophase-separate into relatively large (≫1 μm) A-rich and B-rich phases, between which exists poor interfacial adhesion, due to a low entropy of mixing. The size scale of phase separation in such a blend can be reduced, and the extent of interfacial A-B contact and entanglement enhanced, via addition of an emulsifying agent such as an AB diblock copolymer. Diblock copolymers consist of a long sequence of A monomers covalently bonded to a long sequence of B monomers. These materials are surface-active and decrease interfacial tension between immiscible phases much in the same way as do small-molecule surfactants. Previous studies have clearly demonstrated the utility of block copolymers in compatibilizing homopolymer blends and enhancing blend properties such as fracture toughness. It is now recognized that optimization of emulsified ternary blends relies upon design considerations such as sufficient block penetration into a macrophase (to avoid block slip) and prevention of a copolymer multilayer at the A-B interface (to avoid intralayer failure).


Author(s):  
Peter K. Hepler ◽  
Dale A. Callaham

Calcium ions (Ca) participate in many signal transduction processes, and for that reason it is important to determine where these ions are located within the living cell, and when and to what extent they change their local concentration. Of the different Ca-specific indicators, the fluorescent dyes, developed by Grynkiewicz et al. (1), have proved most efficacious, however, their use on plants has met with several problems (2). First, the dyes as acetoxy-methyl esters are often cleaved by extracellular esterases in the plant cell wall, and thus they do not enter the cell. Second, if the dye crosses the plasma membrane it may continue into non-cytoplasmic membrane compartments. Third, even if cleaved by esterases in the cytoplasm, or introduced as the free acid into the cytoplasmic compartment, the dyes often become quickly sequestered into vacuoles and organelles, or extruded from the cell. Finally, the free acid form of the dye readily complexes with proteins reducing its ability to detect free calcium. All these problems lead to an erroneous measurement of calcium (2).


Author(s):  
Ray Keller

The amphibian embryo offers advantages of size, availability, and ease of use with both microsurgical and molecular methods in the analysis of fundamental developmental and cell biological problems. However, conventional wisdom holds that the opacity of this embryo limits the use of methods in optical microscopy to resolve the cell motility underlying the major shape-generating processes in early development.These difficulties have been circumvented by refining and adapting several methods. First, methods of explanting and culturing tissues were developed that expose the deep, nonepithelial cells, as well as the superficial epithelial cells, to the view of the microscope. Second, low angle epi-illumination with video image processing and recording was used to follow patterns of cell movement in large populations of cells. Lastly, cells were labeled with vital, fluorescent dyes, and their behavior recorded, using low-light, fluorescence microscopy and image processing. Using these methods, the details of the cellular protrusive activity that drives the powerful convergence (narrowing)


Sign in / Sign up

Export Citation Format

Share Document