Monitoring Coil–Globule Transitions of Thermoresponsive Polymers by Using NMR Solvent Relaxation

2018 ◽  
Vol 122 (22) ◽  
pp. 6094-6100 ◽  
Author(s):  
Ipsita Chakraborty ◽  
Kaustuv Mukherjee ◽  
Priyadarsi De ◽  
Rangeet Bhattacharyya
2021 ◽  
Author(s):  
Maximilian Felix Toni Meier ◽  
Franck Thetiot ◽  
Narsimhulu Pittala ◽  
Ingo Lieberwirth ◽  
Cleiton Kunzler ◽  
...  

We have designed novel macromolecular coordination ligands (MCLs) by conjugation of thermoresponsive polymers based on poly(N-isopropylacrylamide) (M ̅_n around 3 to 25 kg∙mol-1) with 1,2,4-triazole coordination sites. These triazole units...


Polymers ◽  
2020 ◽  
Vol 13 (1) ◽  
pp. 90
Author(s):  
Łukasz Otulakowski ◽  
Maciej Kasprów ◽  
Aleksandra Strzelecka ◽  
Andrzej Dworak ◽  
Barbara Trzebicka

Thermoresponsive polymers are a promising material for drug nanocarrier preparation, which makes the study of their aggregation in physiological conditions very important. In this paper, the thermal behaviour of the thermoresponsive polymers poly(N-isopropylacrylamide), poly(2-isopropyl-2-oxazoline-co-2-n-propyl-2-oxazoline) and poly[(2-hydroxyethyl methacrylate)-co-oligo(ethylene glycol) methyl ether methacrylate] were studied in phosphate buffer (PBS) and solutions of its salts in concentration as in PBS. The thermal response of the polymers was measured using UV-Vis and dynamic light scattering (DLS). The salts shifted the cloud point temperature (TCP) of the (co)polymers to higher values compared to the TCP of aqueous polymer solutions. In PBS and NaCl solutions, all polymers exhibited an unexpected and previously unreported transmittance profile. During heating, an additional aggregation of polymers appeared above the TCP accompanied by the formation of a precipitate. In monosodium phosphate solutions and pure water, the studied polymers showed lower critical solution temperature (LCST-type) behaviour. DLS measurements showed that a salt influenced the size of the resulting polymer particles. The sizes and stability of particles depended on the heating rate. In PBS and NaCl solutions, the size of particles in the dispersion decreased above 60 °C, and the precipitate appeared on the bottom of the cuvette. The additional aggregation of polymer and its falling out of solution may hinder the removal of carriers from the body and has to be taken into account when preparing nanocarriers.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Kenichi Nagase ◽  
Yuta Umemoto ◽  
Hideko Kanazawa

AbstractTemperature-responsive chromatography using thermoresponsive polymers is innovative and can control analyte retention via column temperature. Analyte elution behavior in this type of chromatography depends on the modified thermoresponsive polymer and the structure of the base materials. In the present study, we examine the effect of the pore diameter of silica beads on analyte elution behavior in temperature-responsive chromatography. Poly(N-isopropylacrylamide-co-n-butyl methacrylate) hydrogel was applied to beads of various pore sizes: 7, 12, and 30 nm. Almost the same amount of copolymer hydrogel was applied to all beads, indicating that the efficiency of copolymer modification was independent of pore size. Analyte retention on prepared beads in a packed column was observed using steroids, benzodiazepines, and barbiturates as analytes. Analyte retention times increased with temperature on packed columns of 12- and 30-nm beads, whereas the column packed with 7-nm beads exhibited decreased retention times with increasing temperature. The difference in analyte elution behavior among the various pore sizes was attributed to analyte diffusion into the bead pores. These results demonstrate that bead pore diameter determines temperature-dependent elution behavior.


Cells ◽  
2021 ◽  
Vol 10 (4) ◽  
pp. 877
Author(s):  
Ingrid Zahn ◽  
Daniel David Stöbener ◽  
Marie Weinhart ◽  
Clemens Gögele ◽  
Annette Breier ◽  
...  

Anterior cruciate ligament (ACL) cell sheets combined with biomechanically competent scaffolds might facilitate ACL tissue engineering. Since thermoresponsive polymers allow a rapid enzyme-free detachment of cell sheets, we evaluated the applicability of a thermoresponsive poly(glycidyl ether) (PGE) coating for cruciate ligamentocyte sheet formation and its influence on ligamentocyte phenotype during sheet-mediated colonization of embroidered scaffolds. Ligamentocytes were seeded on surfaces either coated with PGE or without coating. Detached ligamentocyte sheets were cultured separately or wrapped around an embroidered scaffold made of polylactide acid (PLA) and poly(lactic-co-ε-caprolactone) (P(LA-CL)) threads functionalized by gas-phase fluorination and with collagen foam. Ligamentocyte viability, protein and gene expression were determined in sheets detached from surfaces with or without PGE coating, scaffolds seeded with sheets from PGE-coated plates and the respective monolayers. Stable and vital ligamentocyte sheets could be produced within 24 h with both surfaces, but more rapidly with PGE coating. PGE did not affect ligamentocyte phenotype. Scaffolds could be colonized with sheets associated with high cell survival, stable gene expression of ligament-related type I collagen, decorin, tenascin C and Mohawk after 14 d and extracellular matrix (ECM) deposition. PGE coating facilitates ligamentocyte sheet formation, and sheets colonizing the scaffolds displayed a ligament-related phenotype.


2010 ◽  
Vol 46 (10) ◽  
pp. 1631 ◽  
Author(s):  
Ning Yan ◽  
Jiaguang Zhang ◽  
Yuan Yuan ◽  
Guang-Tao Chen ◽  
Paul. J. Dyson ◽  
...  

2016 ◽  
Vol 120 (20) ◽  
pp. 4635-4643 ◽  
Author(s):  
Qilu Zhang ◽  
Lenny Voorhaar ◽  
Sergey K. Filippov ◽  
Berin Fatma Yeşil ◽  
Richard Hoogenboom

2014 ◽  
Vol 183 ◽  
pp. 1-8 ◽  
Author(s):  
Roopali Saxena ◽  
Sandeep Shrivastava ◽  
Sourav Haldar ◽  
Andrey S. Klymchenko ◽  
Amitabha Chattopadhyay

Sign in / Sign up

Export Citation Format

Share Document