Fabrication of Multifunctional Gd2O3/Au Hybrid Nanoprobe via a One-Step Approach for Near-Infrared Fluorescence and Magnetic Resonance Multimodal Imaging in Vivo

2013 ◽  
Vol 85 (17) ◽  
pp. 8436-8441 ◽  
Author(s):  
Shao-Kai Sun ◽  
Lu-Xi Dong ◽  
Yang Cao ◽  
Hao-Ran Sun ◽  
Xiu-Ping Yan
PLoS ONE ◽  
2014 ◽  
Vol 9 (2) ◽  
pp. e90589 ◽  
Author(s):  
Kiran Vasudeva ◽  
Karl Andersen ◽  
Bree Zeyzus-Johns ◽  
T. Kevin Hitchens ◽  
Sravan Kumar Patel ◽  
...  

Nanoscale ◽  
2014 ◽  
Vol 6 (15) ◽  
pp. 9264-9272 ◽  
Author(s):  
Gary Sitbon ◽  
Sophie Bouccara ◽  
Mariana Tasso ◽  
Aurélie Francois ◽  
Lina Bezdetnaya ◽  
...  

Cadmium-free quantum dots doped with Mn2+ions show promising results forin vivobimodal MRI and NIR fluorescence imaging.


2010 ◽  
Vol 46 (21) ◽  
pp. 3705 ◽  
Author(s):  
Kevin Guo ◽  
Mikhail Y. Berezin ◽  
Jie Zheng ◽  
Walter Akers ◽  
Franck Lin ◽  
...  

Immunobiology ◽  
2015 ◽  
Vol 220 (12) ◽  
pp. 1328-1336 ◽  
Author(s):  
Hua He ◽  
Xiaojie Tu ◽  
Juan Zhang ◽  
Desmond Omane Acheampong ◽  
Li Ding ◽  
...  

2017 ◽  
Vol 53 (62) ◽  
pp. 8759-8762 ◽  
Author(s):  
Yu Fang ◽  
Wei Chen ◽  
Wen Shi ◽  
Hongyu Li ◽  
Ming Xian ◽  
...  

A new near-infrared fluorescence off–on probe with phenyl 2-(benzoylthio)benzoate as the recognition moiety is developed and applied in imaging H2Sn in living cells and mice in vivo.


2015 ◽  
Vol 51 (32) ◽  
pp. 6948-6951 ◽  
Author(s):  
Yanfeng Zhang ◽  
Qian Yin ◽  
Jonathan Yen ◽  
Joanne Li ◽  
Hanze Ying ◽  
...  

Anin vitroandin vivodrug-reporting system is developed for real-time monitoring of drug release via the analysis of the concurrently released near-infrared fluorescence dye.


2015 ◽  
Vol 42 (7) ◽  
pp. 1112-1118 ◽  
Author(s):  
Michaela Krohn ◽  
Sarah Ohrndorf ◽  
Stephanie G. Werner ◽  
Bernd Schicke ◽  
Gerd-Rüdiger Burmester ◽  
...  

Objective.Near-infrared fluorescence optical imaging (FOI) is a novel imaging technology in the detection and evaluation of different arthritides. FOI was validated in comparison to magnetic resonance imaging (MRI), greyscale ultrasonography (GSUS), and power Doppler ultrasonography (PDUS) in patients with early rheumatoid arthritis (RA).Methods.Hands of 31 patients with early RA were examined by FOI, MRI, and US. In each modality, synovitis of the wrist, metacarpophalangeal joints (MCP) 2–5, and proximal interphalangeal joints (PIP) 2–5 were scored on a 4-point scale (0–3). Sensitivity and specificity of FOI were analyzed in comparison to MRI and US as reference methods, differentiating between 3 phases of FOI enhancement (P1–3). Intraclass correlation coefficients (ICC) were calculated to evaluate the agreement of FOI with MRI and US.Results.A total of 279 joints (31 wrists, 124 MCP and 124 PIP joints) were evaluated. With MRI as the reference method, overall sensitivity/specificity of FOI was 0.81/0.00, 0.49/0.84, and 0.86/0.38 for wrist, MCP, and PIP joints, respectively. Under application of PDUS as reference, sensitivity was even higher, while specificity turned out to be low, except for MCP joints (0.88/0.15, 0.81/0.76, and 1.00/0.27, respectively). P2 appears to be the most sensitive FOI phase, while P1 showed the highest specificity. The best agreement of FOI was shown for PDUS, especially with regard to MCP and PIP joints (ICC of 0.57 and 0.53, respectively), while correlation with MRI was slightly lower.Conclusion.FOI remains an interesting diagnostic tool for patients with early RA, although this study revealed limitations concerning the detection of synovitis. Further research is needed to evaluate its full diagnostic potential in rheumatic diseases.


Sign in / Sign up

Export Citation Format

Share Document