Potentiometric Response Characteristics of Polycation-Sensitive Membrane Electrodes toward Poly(amidoamine) and Poly(propylenimine) Dendrimers

2004 ◽  
Vol 76 (5) ◽  
pp. 1474-1482 ◽  
Author(s):  
Stacey A. Nevins Buchanan ◽  
Lajos P. Balogh ◽  
Mark E. Meyerhoff
Chemosensors ◽  
2020 ◽  
Vol 9 (1) ◽  
pp. 4
Author(s):  
Ville Yrjänä ◽  
Indrek Saar ◽  
Mihkel Ilisson ◽  
Sandip A. Kadam ◽  
Ivo Leito ◽  
...  

Solid-contact ion-selective electrodes with carbazole-derived ionophores were prepared. They were characterized as acetate sensors, but can be used to determine a number of carboxylates. The potentiometric response characteristics (slope, detection limit, selectivity, and pH sensitivity) of sensors prepared with different membrane compositions (ionophore, ionophore concentration, anion exchanger concentration, and plasticizer) were evaluated. The results show that for the macrocyclic ionophores, a larger cavity provided better selectivity. The sensors exhibited modest selectivity for acetate but good selectivity for benzoate. The carbazole-derived ionophores effectively decreased the interference from lipophilic anions, such as bromide, nitrate, iodide, and thiocyanate. The selectivity, detection limit, and linear range were improved by choosing a suitable plasticizer and by reducing the ionophore and anion exchanger concentrations. The influence of the electrode body’s material upon the composition of the plasticized poly(vinyl chloride) membrane, and thus also upon the sensor characteristics, was also studied. The choice of materials for the electrode body significantly affected the characteristics of the sensors.


Sensors ◽  
2021 ◽  
Vol 21 (5) ◽  
pp. 1612
Author(s):  
Andrea Paut ◽  
Ante Prkić ◽  
Ivana Mitar ◽  
Perica Bošković ◽  
Dražan Jozić ◽  
...  

A novel ion-selective electrode with membranes based on iron(III) phosphate and silver sulfide integrated into a completely new electrode body design has been developed for the determination of iron(III) cations. The best response characteristics with linear potential change were found in the iron(III) concentration range from 3.97× 10−5 to 10−2 mol L−1. The detection limit was found to be 2.41× 10−5 mol L−1 with a slope of –20.53 ± 0.63 and regression coefficient of 0.9925, while the quantification limit was 3.97× 10−5 M. The potential change per concentration decade ranged from –13.59 ± 0.54 to –20.53 ± 1.56 for Electrode Body 1 (EB1) and from –17.28 ± 1.04 to –24 ± 1.87 for Electrode Body 2 (EB2), which is presented for the first time in this work. The prepared electrode has a long lifetime and the ability to detect changes in the concentration of iron cations within 20 s. Membrane M1 showed high recoveries in the determination of iron cations in iron(III) standard solutions (98.2–101.2%) as well as in two different pharmaceuticals (98.6–106.5%). This proves that this type of sensor is applicable in the determination of ferric cations in unknown samples, and the fact that all sensor parts are completely manufactured in our laboratory proves the simplicity of the method.


Sensors ◽  
2018 ◽  
Vol 18 (7) ◽  
pp. 2297 ◽  
Author(s):  
Dana Vlascici ◽  
Nicoleta Plesu ◽  
Gheorghe Fagadar-Cosma ◽  
Anca Lascu ◽  
Mihaela Petric ◽  
...  

Pt(II) 5,10,15,20-tetra(4-methoxy-phenyl)-porphyrin (PtTMeOPP) was used in the construction of new ion-selective sensors. The potentiometric response characteristics (slope and selectivity) of iodide and bromide-selective electrodes based on (PtTMeOPP) metalloporphyrin in o-nitrophenyloctylether (NPOE), dioctylphtalate (DOP) and dioctylsebacate (DOS) plasticized poly(vinyl chloride) membranes are compared. The best results were obtained for the membranes plasticized with DOP and NPOE. The sensors have linear responses with near-Nernstian slopes toward bromide and iodide ions and good selectivity. The membrane plasticized with NPOE was electrochemically characterized using the EIS method to determine its water absorption and the diffusion coefficient into the membrane.


2015 ◽  
Vol 877 ◽  
pp. 1-8 ◽  
Author(s):  
Ji Min Kim ◽  
Loc Nguyen ◽  
Mary Frances Barr ◽  
Michael Morabito ◽  
Damien Stringer ◽  
...  

2012 ◽  
Vol 9 (4) ◽  
pp. 1941-1950 ◽  
Author(s):  
Hassan Ali Zamani ◽  
Mojdeh Zaferoni ◽  
Soraia Meghdadi

The N-benzoylethylidene-2-aminobenzylamine (BEA) was used as a suitable ionophore in construction of neodymium ion selective electrode. The electrode with composition of 30% PVC, 58% solvent mediator (NB), 2% ionophore (BEA) and 10% anionic additive (OA) shows the best potentiometric response characteristics. The Nd3+sensor exhibits a Nernstian slope of 21.2 ± 0.2 mV decade-1over the concentration range of 1.0 × 10-6to 1.0 × 10-2mol L-1, and a detection limit of 6.3 × 10-7mol L-1of Nd3+ions. The potentiometric response of the sensor is independent of the solution pH in the range of 2.4–8.5. It has a very short response time, in the whole concentration range (~7 s), and can be used for at least eight weeks. The proposed sensor revealed high selectivity with respect to all common alkali, alkaline earth, transition and heavy metal ions, including members of the lanthanide family other than Nd3+. The Nd3+sensor was successfully applied as an indicator electrode in the potentiometric titration of Nd3+ions with EDTA. The electrode was also employed for the determination of the fluoride ion in two mouth wash preparations.


1990 ◽  
Vol 239 ◽  
pp. 23-27 ◽  
Author(s):  
Takashi Katsu ◽  
Takashi Kayamoto ◽  
Yuzaburo Fujita

Sign in / Sign up

Export Citation Format

Share Document