Long-term performance of a gas chromatography/tandem mass spectrometry assay for tebufelone in plasma

1990 ◽  
Vol 62 (17) ◽  
pp. 1819-1824 ◽  
Author(s):  
Roy L. M. Dobson ◽  
David M. Neal ◽  
Bruce R. DeMark ◽  
Susan R. Ward
2021 ◽  
Vol 9 ◽  
Author(s):  
José J. Pérez ◽  
Clifford H. Watson ◽  
Benjamin C. Blount ◽  
Liza Valentín-Blasini

The long-term health effects of using e-cigarette, or vaping, products (EVPs; also known as e-cigarettes, electronic nicotine delivery systems, and vape pens) remain largely unknown. The inhalation of excipients, such as propylene glycol (PG) and glycerin (GLY), may have long-term health effects. In addition to the direct health effects of PG and GLY, glycerin-containing products can be contaminated with toxic ethylene glycol (EG) and diethylene glycol (DEG). To assess this issue, we developed a simple, versatile, high-throughput isotope dilution gas chromatography-tandem mass spectrometry method for quantifying these common excipients and contaminants. The method is applicable to both the liquid contents and machine-generated aerosols of EVPs. Our rigorous method validation demonstrates that the new method is specific, precise, accurate, and rugged/robust. The calibration range is linear from 0.1–7 mg for the excipients and 2.5–1,000 µg for the contaminants. These ranges encompass expected excipients levels in EVP e-liquids and their machine-generated aerosols and the relevant maximum residue safety limit of 1 mg/g, or 0.1% (w/w), for the contaminants. The calculated limits of detection for PG, GLY, EG, and DEG were determined as 0.0109 mg, 0.0132 mg, 0.250 µg, and 0.100 µg, respectively. The method was applied to the aerosol emissions analysis of 141 EVPs associated with the 2019 lung injury outbreak, and found typical levels of PG (120.28–689.35 mg/g of aerosol) and GLY (116.83–845.96 mg/g of aerosol) in all nicotine-containing products; PG (81.58–491.92 mg/g of aerosol) and GLY (303.86–823.47 mg/g of aerosol) in 13% of cannabidiol (CBD) products; PG (74.02–220.18 mg/g of aerosol) and GLY (596.43–859.81 mg/g of aerosol) in products with neither nicotine nor CBD; and none detected in tetrahydrocannabinol (THC) products. No products contained glycol contaminants above the recommended maximum residue safety limit.


Water ◽  
2021 ◽  
Vol 13 (5) ◽  
pp. 655
Author(s):  
Mohamed H. EL-Saeid ◽  
Modhi. O. Alotaibi ◽  
Mashael Alshabanat ◽  
Murefah Mana AL-Anazy ◽  
Khadijah R. Alharbi ◽  
...  

Pesticide residues are harmful to the environment and human and animal health even at low levels because of long-term bioaccumulation. In this study, photolysis was applied to treat three representative water samples: aqueous atrazine and dimethoate solutions as target pesticides, as well as wastewater and agriculture wastewater containing pesticide residue. It was performed using ultraviolet (UV) irradiation at two wavelengths (254 and 306 nm) with exposure times ranging from 2 to 12 h in the presence and absence of a photocatalyst to identify the optimal degradation conditions. Extraction and analyzation process were performed by the Quick Easy Cheap Effective Rugged Safe (QuEChERS) methods and gas chromatography–tandem mass spectrometry with triple quadrupole detector (GC–MSMS/TQD), respectively. Photodegradation increased with an increase in exposure time and the TiO2 catalyst was beneficial for degradation. Both selected irradiation wavelengths were effective, although the wavelength of λ = 306 nm was the most efficient.


Sign in / Sign up

Export Citation Format

Share Document