scholarly journals A Nondestructive Prescreening Method for Bone Collagen Content Using Micro-Computed Tomography

Radiocarbon ◽  
2010 ◽  
Vol 52 (2) ◽  
pp. 612-619 ◽  
Author(s):  
Jennifer A Tripp ◽  
Maria E Squire ◽  
Julie Hamilton ◽  
Robert E M Hedges

Isolation of bone collagen for radiocarbon dating is a labor-intensive and time-consuming process that sometimes results in unacceptably low protein recovery. In preliminary studies reported here, micro-computed tomography (microCT), a nondestructive technique that uses X-rays to produce high-resolution three-dimensional images of mineralized materials such as bone, offers promise as a suitable prescreening option for bones of questionable preservation. We have found that the bone volume fraction calculated by the scanner software correlates well with collagen recovery in 4 analyzed bones from Etton, United Kingdom.

2006 ◽  
Vol 12 (2) ◽  
pp. 97-105 ◽  
Author(s):  
Bert Müller ◽  
Marco Riedel ◽  
Philipp J. Thurner

Micro-computed tomography with the highly intense, monochromatic X rays produced by the synchrotron is a superior method to nondestructively measure the local absorption in three-dimensional space. Because biological tissues and cells consist mainly of water as the surrounding medium, higher absorbing agents have to be incorporated into the structures of interest. Even without X-ray optics such as refractive lens, one can uncover the stain distribution with the spatial resolution of about 1 μm. Incorporating the stain at selected cell compartments, for example, binding to the RNA/DNA, their density distribution becomes quantified. In this communication, we demonstrate that tomograms obtained at the beamlines BW2 and W2 (HASYLAB at DESY, Hamburg, Germany) and 4S (SLS, Villigen, Switzerland) clearly show that the RNA/DNA-stained HEK 293 cell clusters have a core of high density and a peripheral part of lower density, which correlate with results of optical microscopy. The inner part of the clusters is associated with nonvital cells as the result of insufficient oxygen and nutrition supply. This necrotic part is surrounded by (6 ± 1) layers of vital cells.


2019 ◽  
Vol 48 (2) ◽  
pp. 595-605 ◽  
Author(s):  
S. S. Karhula ◽  
M. A. J. Finnilä ◽  
S. J. O. Rytky ◽  
D. M. Cooper ◽  
J. Thevenot ◽  
...  

Abstract The aim of this study was to quantify sub-resolution trabecular bone morphometrics, which are also related to osteoarthritis (OA), from clinical resolution cone beam computed tomography (CBCT). Samples (n = 53) were harvested from human tibiae (N = 4) and femora (N = 7). Grey-level co-occurrence matrix (GLCM) texture and histogram-based parameters were calculated from CBCT imaged trabecular bone data, and compared with the morphometric parameters quantified from micro-computed tomography. As a reference for OA severity, histological sections were subjected to OARSI histopathological grading. GLCM and histogram parameters were correlated to bone morphometrics and OARSI individually. Furthermore, a statistical model of combined GLCM/histogram parameters was generated to estimate the bone morphometrics. Several individual histogram and GLCM parameters had strong associations with various bone morphometrics (|r| > 0.7). The most prominent correlation was observed between the histogram mean and bone volume fraction (r = 0.907). The statistical model combining GLCM and histogram-parameters resulted in even better association with bone volume fraction determined from CBCT data (adjusted R2 change = 0.047). Histopathology showed mainly moderate associations with bone morphometrics (|r| > 0.4). In conclusion, we demonstrated that GLCM- and histogram-based parameters from CBCT imaged trabecular bone (ex vivo) are associated with sub-resolution morphometrics. Our results suggest that sub-resolution morphometrics can be estimated from clinical CBCT images, associations becoming even stronger when combining histogram and GLCM-based parameters.


Author(s):  
Xiaowei S. Liu ◽  
X. Henry Zhang ◽  
Paul Sajda ◽  
Punam K. Saha ◽  
Felix W. Wehrli ◽  
...  

Osteoporosis is an age-related disease characterized by low bone mass and architectural deterioration. Other than bone volume fraction (BV/TV), microarchitecture of trabecular bone, such as trabecular type (rods or plates), connectivity, and orientation of the trabecular network is also believed to be important in governing the mechanical properties of trabecular bone. A recent study [1] showed that the microarchitecture alone affects elastic moduli of trabecular bone and, further, that trabecular plates make a far greater contribution than rods. In human vertebral trabecular bone, the roles of transverse vs. vertical rods in conferring mechanical properties of trabecular bone have been debated [2, 3]. It has been suggested that the role of transverse trabecular rod is critical in determining elastic modulus of vertebral trabecular bone. However, without explicit classifications of trabecular type, or orientation assessment at an individual trabecula level, it is not possible yet to test this hypothesis in human trabecular bone samples despite the development of three-dimensional (3D) micro computed tomography (μCT) and μCT based finite element (FE) models of human trabecular bone. With the newly developed technique of complete volumetric decomposition and individual trabecula based orientation analyses [4], now it is possible to quantitatively examine the contributions of trabecular rods of various orientations in the elastic properties of vertebral trabecular bone.


2000 ◽  
Vol 164 (2) ◽  
pp. 239-245 ◽  
Author(s):  
T Yamashita ◽  
Y Nabeshima ◽  
M Noda

Inactivation mutation of the recently discovered klotho gene in mice causes a syndrome resembling aging. Manifestations include short life span, atherosclerosis, gonadal atropy, skin atropy, emphysema, ataxia and ectopic calcification. These mice also exhibit abnormally high bone density in the epiphyses of their tibiae based on X-ray and histological analyses. However, micro-structures of the trabecular bones in arbitrary two-dimensional planes or three-dimensional regions are difficult to analyze by these techniques. Therefore, we applied high resolution micro-computed tomography (microCT) to characterize the micro-structural abnormality in the trabecular bone in long bones as well as in vertebrae of four- to six-week-old klotho mutant mice. Two-dimensional microCT analyses in the mid-sagittal plane as well as three-dimensional microCT analyses indicated that the trabecular bone volume fraction measured in the proximal metaphyses of the tibiae was increased more than twofold in klotho mutant mice compared with the wild-type mice. Similarly, the trabecular bone area fraction in the mid-sagittal plane of the lumbar vertebral bodies was also increased by about 80% at the proximal and distal ends. No significant difference was observed with regard to the cortical thickness in the mid-shaft of femora between klotho mutant and wild-type mice. Three-dimensional microCT analyses also indicated that the trabecular number and thickness of the proximal metaphyses of the tibiae were increased by about 80% and 300% respectively in the klotho mutant mice, while trabecular separation was 60% less in klotho mutant mice compared with the wild-type mice. These quantitative microCT analyses indicate that the inactivation of klotho gene expression results in an increase in three-dimensional bone volume fraction, number and thickness of the trabecular bones in these mice.


Author(s):  
Theodore J. Heindel ◽  
Terrence C. Jensen ◽  
Joseph N. Gray

There are several methods available to visualize fluid flows when one has optical access. However, when optical access is limited to near the boundaries or not available at all, alternative visualization methods are required. This paper will describe flow visualization using an X-ray system that is capable of digital X-ray radiography, digital X-ray stereography, and digital X-ray computed tomography (CT). The unique X-ray flow visualization facility will be briefly described, and then flow visualization of various systems will be shown. Radiographs provide a two-dimensional density map of a three dimensional process or object. Radiographic images of various multiphase flows will be presented. When two X-ray sources and detectors simultaneously acquire images of the same process or object from different orientations, stereographic imaging can be completed; this type of imaging will be demonstrated by trickling water through packed columns and by absorbing water in a porous medium. Finally, local time-averaged phase distributions can be determined from X-ray computed tomography (CT) imaging, and this will be shown by comparing CT images from two different gas-liquid sparged columns.


2021 ◽  
pp. 105566562110363
Author(s):  
Jiuli Zhao ◽  
Hengyuan Ma ◽  
Yongqian Wang ◽  
Tao Song ◽  
Chanyuan Jiang ◽  
...  

Objective Palatoplasty would involve the structures around the pterygoid hamulus. However, clinicians hold different opinions on the optimal approach for the muscles and palatine aponeurosis around the pterygoid hamulus. The absence of a consensus regarding this point can be attributed to the lack of investigations on the exact anatomy of this region. Therefore, we used micro-computed tomography to examine the anatomical structure of the region surrounding the pterygoid hamulus. Design Cadaveric specimens were stained with iodine–potassium iodide and scanned by micro-computed tomography to study the structures of the tissues, particularly the muscle fibers. We imported Digital Imaging and Communications in Medicine images to Mimics to reconstruct a 3-dimensional model and simplified the model. Results Three muscles were present around the pterygoid hamulus, namely the palatopharyngeus (PP), superior constrictor (SC), and tensor veli palatini (TVP). The hamulus connects these muscles as a key pivot. The TVP extended to the palatine aponeurosis, which bypassed the pterygoid hamulus, and linked the PP and SC. Some muscle fibers of the SC originated from the hamulus, the aponeurosis of which was wrapped around the hamulus. There was a distinct gap between the pterygoid hamulus and the palatine aponeurosis. This formed a pulley-like structure around the pterygoid hamulus. Conclusions Transection or fracture of the palatine aponeurosis or pterygoid hamulus, respectively, may have detrimental effects on the muscles around the pterygoid hamulus, which play essential roles in the velopharyngeal function and middle ear ventilation. Currently, cleft palate repair has limited treatment options with proven successful outcomes.


2013 ◽  
Vol 7 (1) ◽  
pp. 47-54 ◽  
Author(s):  
Emi Yamashita-Mikami ◽  
Mikako Tanaka ◽  
Naoki Sakurai ◽  
Kazuho Yamada ◽  
Hayato Ohshima ◽  
...  

The subject was a 53-year-old male. An alveolar bone sample was obtained from the site of the lower left first molar, before dental implant placement. Although the details of the trabecular structure were not visible with conventional computed tomography, micro-computed tomography (microCT) three-dimensional images of the alveolar bone biopsy sample showed several plate-like trabeculae extending from the lingual cortical bone. Histological observations of the bone sample revealed trabeculae, cuboidal osteoblasts, osteoclasts and hematopoietic cells existing in the bone tissue at the implantation site. Bone metabolic markers and calcaneal bone density were all within normal ranges, indicating no acceleration of the patient’s bone metabolism.Using microCT, and histological and histomorphometrical techniques, a great deal of valuable information about the bone tissue was obtained from a biopsy sample extracted from the patient’s planned implant site.


2014 ◽  
Vol 695 ◽  
pp. 588-591
Author(s):  
Khairul Salleh Basaruddin ◽  
Ruslizam Daud

This study aims to investigate the influence of trabecular bone in human mandible bone on the mechanical response under implant load. Three dimensional voxel finite element (FE) model of mandible bone was reconstructed from micro-computed tomography (CT) images that were captured from bone specimen. Two FE models were developed where the first consists of cortical bone, trabecular bone and implants, and trabecular bone part was excluded in the second model. A static analysis was conducted on both models using commercial software Voxelcon. The results suggest that trabecular bone contributed to the strength of human mandible bone and to the effectiveness of load distribution under implant load.


PeerJ ◽  
2018 ◽  
Vol 6 ◽  
pp. e5156 ◽  
Author(s):  
Leoni Georgiou ◽  
Tracy L. Kivell ◽  
Dieter H. Pahr ◽  
Matthew M. Skinner

BackgroundIn addition to external bone shape and cortical bone thickness and distribution, the distribution and orientation of internal trabecular bone across individuals and species has yielded important functional information on how bone adapts in response to load. In particular, trabecular bone analysis has played a key role in studies of human and nonhuman primate locomotion and has shown that species with different locomotor repertoires display distinct trabecular architecture in various regions of the skeleton. In this study, we analyse trabecular structure throughout the distal femur of extant hominoids and test for differences due to locomotor loading regime.MethodsMicro-computed tomography scans ofHomo sapiens(n= 11),Pan troglodytes(n= 18),Gorilla gorilla(n= 14) andPongosp. (n= 7) were used to investigate trabecular structure throughout the distal epiphysis of the femur. We predicted that bone volume fraction (BV/TV) in the medial and lateral condyles inHomowould be distally concentrated and more anisotropic due to a habitual extended knee posture at the point of peak ground reaction force during bipedal locomotion, whereas great apes would show more posteriorly concentrated BV/TV and greater isotropy due to a flexed knee posture and more variable hindlimb use during locomotion.ResultsResults indicate some significant differences between taxa, with the most prominent being higher BV/TV in the posterosuperior region of the condyles inPanand higher BV/TV and anisotropy in the posteroinferior region inHomo. Furthermore, trabecular number, spacing and thickness differ significantly, mainly separatingGorillafrom the other apes.DiscussionThe trabecular architecture of the distal femur holds a functional signal linked to habitual behaviour; however, there was more similarity across taxa and greater intraspecific variability than expected. Specifically, there was a large degree of overlap in trabecular structure across the sample, andHomowas not as distinct as predicted. Nonetheless, this study offers a comparative sample of trabecular structure in the hominoid distal femur and can contribute to future studies of locomotion in extinct taxa.


2021 ◽  
Vol 8 (11) ◽  
Author(s):  
Matthew J. Lawson ◽  
Orestis L. Katsamenis ◽  
David Chatelet ◽  
Aiman Alzetani ◽  
Oliver Larkin ◽  
...  

Micro-computed tomography (µCT) provides non-destructive three-dimensional (3D) imaging of soft tissue microstructures. Specific features in µCT images can be identified using correlated two-dimensional (2D) histology images allowing manual segmentation. However, this is very time-consuming and requires specialist knowledge of the tissue and imaging modalities involved. Using a custom-designed µCT system optimized for imaging unstained formalin-fixed paraffin-embedded soft tissues, we imaged human lung tissue at isotropic voxel sizes less than 10 µm. Tissue sections were stained with haematoxylin and eosin or cytokeratin 18 in columnar airway epithelial cells using immunofluorescence (IF), as an exemplar of this workflow. Novel utilization of tissue autofluorescence allowed automatic alignment of 2D microscopy images to the 3D µCT data using scripted co-registration and automated image warping algorithms. Warped IF images, which were accurately aligned with the µCT datasets, allowed 3D segmentation of immunoreactive tissue microstructures in the human lung. Blood vessels were segmented semi-automatically using the co-registered µCT datasets. Correlating 2D IF and 3D µCT data enables accurate identification, localization and segmentation of features in fixed soft lung tissue. Our novel correlative imaging workflow provides faster and more automated 3D segmentation of µCT datasets. This is applicable to the huge range of formalin-fixed paraffin-embedded tissues held in biobanks and archives.


Sign in / Sign up

Export Citation Format

Share Document