scholarly journals Convection at an isothermal wall in an enclosure and establishment of stratification

2016 ◽  
Vol 799 ◽  
pp. 448-475 ◽  
Author(s):  
T. Caudwell ◽  
J.-B. Flór ◽  
M. E. Negretti

In this experimental–theoretical investigation, we consider a turbulent plume generated by an isothermal wall in a closed cavity and the formation of heat stratification in the interior. The buoyancy of the plume near the wall and the temperature stratification are measured across a vertical plane with the temperature laser induced fluorescence method, which is shown to be accurate and efficient (precision of $0.2\,^{\circ }$C) for experimental studies on convection. The simultaneous measurement of the velocity field with particle image velocimetry allows for the calculation of the flow characteristics such as the Richardson number and Reynolds stress. This enables us to give a refined description of the wall plume, as well as the circulation and evolution of the stratification in the interior. The wall plume is found to have an inner layer close to the heated boundary with a laminar transport of hardly mixed fluid which causes a relatively warm top layer and an outer layer with a transition from laminar to turbulent at a considerable height. The measured entrainment coefficient is found to be dramatically influenced by the increase in stratification of the ambient fluid. To model the flow, the entrainment model of Morton, Taylor & Turner (Proc. R. Soc. Lond. A, vol. 234 (1196), 1956, pp. 1–23) has first been adapted to the case of an isothermal wall. Differences due to their boundary condition of a constant buoyancy flux, modelled with salt by Cooper & Hunt (J. Fluid Mech., vol. 646, 2010, pp. 39–58), turn out to be small. Next, to include the laminar–turbulent transition of the boundary layer, a hybrid model is constructed which is based on the similarity solutions reported by Worster & Leitch (J. Fluid Mech., vol. 156, 1985, pp. 301–319) for the laminar part and the entrainment model for the turbulent part. Finally, the observed variation of the global entrainment coefficient, which is due to the increased presence of an upper stratified layer with a relatively low entrainment coefficient, is incorporated into both models. All models show reasonable agreement with experimental measurements for the volume, momentum and buoyancy fluxes as well as for the evolution of the stratification in the interior. In particular, the introduction of the variable entrainment coefficient improves all models significantly.

2006 ◽  
Author(s):  
Renqiang Xiong ◽  
J. N. Chung

Flow structures and pressure drops were investigated in rectangular serpentine micro-channels with miter bends which had hydraulic diameters of 0.209mm, 0.395mm and 0.549mm respectively. To evaluate the bend effect, the additional pressure drop due to the miter bend must be obtained. Three groups of micro-channels were fabricated to remove the inlet and outlet losses. A validated micro-particle image velocimetry (μPIV) system was used to achieve the flow structure in a serpentine micro-channel with hydraulic diameter of 0.173mm. The experimental results show the vortices around the outer and inner walls of the bend do not form when Re<100. Those vortices appear and continue to develop with the Re number when Re> 100-300, and the shape and size of the vortices almost remain constant when Re>1000. The bend loss coefficient Kb was observed to be related with the Re number when Re<100, with the Re number and channel size when Re>100. It almost keeps constant and changes in the range of ± 10% When Re is larger than some value in 1300-1500. And a size effect on Kb was also observed.


2018 ◽  
Vol 916 ◽  
pp. 221-225
Author(s):  
Ji Zu Lv ◽  
Liang Yu Li ◽  
Cheng Zhi Hu ◽  
Min Li Bai ◽  
Sheng Nan Chang ◽  
...  

Nanofluids is an innovative study of nanotechnology applied to the traditional field of thermal engineering. It refers to the metal or non-metallic nanopowder was dispersed into water, alcohol, oil and other traditional heat transfer medium, to prepared as a new heat transfer medium with high thermal conductivity. The role of nanofluids in strengthening heat transfer has been confirmed by a large number of experimental studies. Its heat transfer mechanism is mainly divided into two aspects. On the one hand, the addition of nanoparticles enhances the thermal conductivity. On the other hand, due to the interaction between the nanoparticles and base fluid causing the changes in the flow characteristics, which is also the main factor affecting the heat transfer of nanofluids. Therefore, a intensive study on the flow characteristics of nanofluids will make the study of heat transfer more meaningful. In this experiment, the flow characteristics of SiO2-water nanofluids in two-dimensional backward step flow are quantitatively studied by PIV. The results show that under the same Reynolds number, the turbulence of nanofluids is larger than that of pure water. With the increase of nanofluids volume fraction, the flow characteristics are constantly changing. The quantitative analysis proved that the nanofluids disturbance was enhanced compared with the base liquid, which resulting in the heat transfer enhancement.


2004 ◽  
Vol 126 (3) ◽  
pp. 391-398 ◽  
Author(s):  
Brandon S. Field ◽  
Eric Loth

A downward blowing isothermal wall jet at moderate Reynolds numbers (1,500 to 8,500) with significant inflow turbulence (ca. 6%) was investigated. The flow configuration is an idealization of the air curtains of refrigerated display cases. Flow visualization using particle seeding was employed to identify the flow field eddy dynamics. Particle Image Velocimetry was used to examine the velocity fields in terms of mean and fluctuating values. These diagnostics showed that the air curtain entrainment was dominated by a large variety of eddies that engulfed ambient air into the air curtain. The velocity fields generally showed linear spreading, significant deceleration and high turbulence levels (ca. 25%). It was observed that the air curtain dynamics, velocity fields and growth were not significantly sensitive to Reynolds number variation between Re=3,800 and Re=8,500. However, at low air velocities (Re=1,500), the curtain was found to detach, leading to a large air curtain thickness and high curtain entrainment.


Author(s):  
S C M Yu ◽  
J B Zhao

Flow characteristics in straight tubes with an asymmetric bulge have been investigated using particle image velocimetry (PIV) over a range of Reynolds numbers from 600 to 1200 and at a Womersley number of 22. A mixture of glycerine and water (approximately 40:60 by volume) was used as the working fluid. The study was carried out because of their relevance in some aspects of physiological flows, such as arterial flow through a sidewall aneurysm. Results for both steady and pulsatile flow conditions were obtained. It was found that at a steady flow condition, a weak recirculating vortex formed inside the bulge. The recirculation became stronger at higher Reynolds numbers but weaker at larger bulge sizes. The centre of the vortex was located close to the distal neck. At pulsatile flow conditions, the vortex appeared and disappeared at different phases of the cycle, and the sequence was only punctuated by strong forward flow behaviour (near the peak flow condition). In particular, strong flow interactions between the parent tube and the bulge were observed during the deceleration phase. Stents and springs were used to dampen the flow movement inside the bulge. It was found that the recirculation vortex could be eliminated completely in steady flow conditions using both devices. However, under pulsatile flow conditions, flow velocities inside the bulge could not be suppressed completely by both devices, but could be reduced by more than 80 per cent.


Author(s):  
Yunhui Peng ◽  
Quanhong Xu ◽  
Yuzhen Lin

Improvement of the lean blowout limit and more uniform combustor exit temperature distribution are particularly desirable for future aero engine. A triple swirler combination plus an airblast fuel injector might be a promising solution. The design with the triple swirler plus the airblast fuel injector including design A and B was presented and investigated in this paper. Single rectangle sector module combustor was used in the experiment for lean blowout (LBO), and three cups rectangle sector combustor was used for pattern factor (PF) experiments. The LBO and PF experiment data were provided. The primary zone flow field was measured by PIV (Particle Image Velocimetry) under atmospheric pressure and temperature. The result showed that the design A was a promising design, and the primary jet played very important role for flow field of primary zone. The insight relation between flow field and combustion performance could be found out from this paper.


2019 ◽  
Vol 6 (7) ◽  
pp. 182061 ◽  
Author(s):  
Wuhua Li ◽  
Xiangju Cheng ◽  
Jun Xie ◽  
Zhaoli Wang ◽  
Deguang Yu

An in-pond raceway system (IPRS) is an effective intensive aquaculture practice for regions with high water consumption and limited land resources. Water flow and dissolved oxygen (DO) are important for sustainable aquaculture. Several innovations have been made in IPRS design and operation to increase water exchange and DO concentration; one of these is the aeration plug-flow device (APFD). The APFD is commonly used in China as the only power source for water recirculation in aquaculture ponds. Understanding of the hydrodynamics of the system is necessary to improve the design of the IPRS with APFD. To this end, we performed experimental studies on a model system. We measured three-dimensional velocity at various locations using an Acoustic Doppler Velocimeter. Velocity distribution and turbulence characteristics were assessed, and plug-flow characteristics were analysed. Two patterns of velocity and turbulence in horizontal sections were observed: near the APFD, the water flow was intensively pushed downstream and simultaneously recirculated; farther away, the reflux area gradually decreased and the velocity and turbulence distribution trended towards uniform. Secondary flows occurred in different directions, which improved the diffusion of materials and DO retention. The system is effectively self-circulating, and the plug-flow capability may be scaled up for commercial application.


Author(s):  
Sung Yong Jung ◽  
Young Uk Min ◽  
Kyung Lok Lee

The performance characteristics of the radial pump commonly used as a multistage (8 or 10 stage) pump have been investigated experimentally. Due to the complex three-dimensional geometries, the hydraulic performance of multistage pumps is closely related to the internal flows in diffuser and return vanes. In order to investigate the flow characteristics in these regions by Particle Image Velocimetry (PIV) technique, a transparent pump is designed. A 532 nm continuous laser and a high-speed camera are used as a light source and an image acquisition device, respectively. The velocity field information in a diffuser of the radial pump is successfully obtained by two-dimensional PIV measurements at various operating conditions.


Sign in / Sign up

Export Citation Format