Pseudomonas aeruginosa Outbreak in a Neonatal Intensive Care Unit Attributed to Hospital Tap Water

2017 ◽  
Vol 38 (7) ◽  
pp. 801-808 ◽  
Author(s):  
Cara Bicking Kinsey ◽  
Samir Koirala ◽  
Benjamin Solomon ◽  
Jon Rosenberg ◽  
Byron F. Robinson ◽  
...  

OBJECTIVETo investigate an outbreak of Pseudomonas aeruginosa infections and colonization in a neonatal intensive care unit.DESIGNInfection control assessment, environmental evaluation, and case-control study.SETTINGNewly built community-based hospital, 28-bed neonatal intensive care unit.PATIENTSNeonatal intensive care unit patients receiving care between June 1, 2013, and September 30, 2014.METHODSCase finding was performed through microbiology record review. Infection control observations, interviews, and environmental assessment were performed. A matched case-control study was conducted to identify risk factors for P. aeruginosa infection. Patient and environmental isolates were collected for pulsed-field gel electrophoresis to determine strain relatedness.RESULTSIn total, 31 cases were identified. Case clusters were temporally associated with absence of point-of-use filters on faucets in patient rooms. After adjusting for gestational age, case patients were more likely to have been in a room without a point-of-use filter (odds ratio [OR], 37.55; 95% confidence interval [CI], 7.16–∞). Case patients had higher odds of exposure to peripherally inserted central catheters (OR, 7.20; 95% CI, 1.75–37.30) and invasive ventilation (OR, 5.79; 95% CI, 1.39–30.62). Of 42 environmental samples, 28 (67%) grew P. aeruginosa. Isolates from the 2 most recent case patients were indistinguishable by pulsed-field gel electrophoresis from water-related samples obtained from these case-patient rooms.CONCLUSIONSThis outbreak was attributed to contaminated water. Interruption of the outbreak with point-of-use filters provided a short-term solution; however, eradication of P. aeruginosa in water and fixtures was necessary to protect patients. This outbreak highlights the importance of understanding the risks of stagnant water in healthcare facilities.Infect Control Hosp Epidemiol 2017;38:801–808

2004 ◽  
Vol 25 (9) ◽  
pp. 730-734 ◽  
Author(s):  
Kwan Kew Lai ◽  
Stephen P. Baker ◽  
Sally A. Fontecchio

AbstractObjective:To investigate a cluster of patients infected and colonized withSerratia marcescensin a neonatal intensive care unit (NICU).Methods:In June 2001, two neonates in the NICU had clinical infections withS. marcescensand one died. Infection control surveillance data for the NICU revealed that S.marcescenswas rarely isolated from clinical specimens. Surveillance and environmental cultures were performed and isolates were typed using pulsed-field gel electrophoresis. Staff and neonates were cohorted and a waterless, alcohol-based handwashing agent was introduced. A case-control study was performed.Results:From June 2 through August 20, 2001, 11 neonates withS. marcescensinfection and colonization were identified. The incidence ofS. marcescensinfections increased from 0.19 per 1,000 patient-days in 2000 to 0.52 per 1,000 patient-days in 2001 (P< .0001). In the first 3 weeks of the investigation, there were 2 sets of patients and sinks with indistinguishable strains; however, in subsequent weeks, all isolates were of unique strains, signifying no further transmission of the two initial predominant strains. Neonates withS. marcescenswere more likely to have a lower gestational age and birth weight. There was no association between cases and healthcare workers (HCWs).Conclusions:A cluster ofS. marcescenswas quickly terminated after the introduction of preventive measures including cohorting of infected and colonized neonates and HCWs, contact precautions, surveillance cultures, and a waterless, alcohol-based hand antiseptic. Chromosomal typing determined that strains with an indistinguishable pattern were no longer present in the unit after control measures were implemented.


Author(s):  
Emine Öztürk ◽  
Şükrü Yıldız

Objective: The aim of this study was to determine whether pregnant women who developed maternal hypoglycemia during the 75 g Oral Glucose Test (OGT) were at an increased risk for adverse obstetric and neonatal outcomes. Methods: This case-control study was conducted from computer-based medical records of women who delivered in a tertiary center between January 2015 and December 2018. OGT had been performed with 75 gr glucose for gestational diabetes screening at 24-28 weeks of gestation. The pregnants with 1st-hour blood glucose levels less than 90 mg/dl (low GT) were matched with normoglycemic patients according to age, body mass index (BMI), gravida and gestational weeks. Obstetric and neonatal outcomes were assessed. Results: Of the 1249 pregnant women included in the study, 62 (4.9%) were in the Low GT group. Admission to the neonatal intensive care unit (NICU) showed a rate of 3.48 increase in the Low GT group (95% confidence interval: 1.05-11.47, p=0.04). There was no difference between the two groups in the other obstetric and neonatal parameters such as: preeclampsia, preterm delivery, birth weight, and weight gained during pregnancy and the 5-minute Apgar scores adjusted for gestational age (SGA) of the fetus. Conclusion: Low 75 g OGT results are significantly associated with increased risk of neonatal intensive care unit (NICU) admissions.


2000 ◽  
Vol 38 (11) ◽  
pp. 4131-4136 ◽  
Author(s):  
Wil C. Van Der Zwet ◽  
Gerard A. Parlevliet ◽  
Paul H. Savelkoul ◽  
Jeroen Stoof ◽  
Annie M. Kaiser ◽  
...  

In 1998, an outbreak of systemic infections caused byBacillus cereus occurred in the Neonatal Intensive Care Unit of the University Hospital Vrije Universiteit, Amsterdam, The Netherlands. Three neonates developed sepsis with positive blood cultures. One neonate died, and the other two neonates recovered. An environmental survey, a prospective surveillance study of neonates, and a case control study were performed, in combination with molecular typing, in order to identify potential sources and transmission routes of infection. Genotypic fingerprinting by amplified-fragment length polymorphism (AFLP) showed that the three infections were caused by a single clonal type of B. cereus. The same strain was found in trachea aspirate specimens of 35 other neonates. The case control study showed mechanical ventilation with a Sensormedics ventilation machine to be a risk factor for colonization and/or infection (odds ratio, 9.8; 95% confidence interval, 1.1 to 88.2). Prospective surveillance showed that colonization with B. cereusoccurred exclusively in the respiratory tract of mechanically ventilated neonates. The epidemic strain of B. cereus was found on the hands of nursing staff and in balloons used for manual ventilation. Sterilization of these balloons ended the outbreak. We conclude that B. cereus can cause outbreaks of severe opportunistic infection in neonates. Typing by AFLP proved very useful in the identification of the outbreak and in the analysis of strains recovered from the environment to trace the cause of the epidemic.