A procedure for calibration of differential scanning calorimeters

2016 ◽  
Vol 639 ◽  
pp. 10-13 ◽  
Author(s):  
I.A. Sedov ◽  
T.A. Muhametzyanov ◽  
B.N. Solomonov
Author(s):  
G. W. H. Höhne ◽  
W. Hemminger ◽  
H.-J. Flammersheim

Author(s):  
José A. Martinho Simões ◽  
Manuel Minas da Piedade

Physical and chemical changes may often be induced by raising or lowering the temperature of a substance. Typical examples are phase transitions, such as fusion, or chemical reactions, such as the solid state polymerization of sodium chloroacetate, which has an onset at 471 K: ClCH2COONa (cr) ⇋ NaCl (cr) + 1/n − (CH2COO)n − (pol) Differential scanning calorimetry (DSC) was designed to obtain the enthalpy or the internal energy of those processes and also to measure temperature-dependent properties of substances, such as the heat capacity. This is done by monitoring the change of the difference between the heat flow rate or power to a sample (S) and to a reference material (R), ΔΦ = ΦS − ΦR = (dQ/dt)S − (dQ/dt)R, as a function of time or temperature, while both S and R are subjected to a controlled temperature program. The temperature is usually increased or decreased linearly at a predetermined rate, but the apparatus can also be used isothermally. In some cases DSC experiments may provide kinetic data. According to Wunderlich, differential scanning calorimeters evolved from the differential thermal analysis (DTA) instruments built by Kurnakov at the beginning of the twentieth century. In these early DTA apparatus, the temperature difference between a sample and a reference, simultaneously heated by a single heat source, was measured as a function of time. No calorimetric data could be derived, and the instruments were used, for example, to determine the temperatures of phase transitions and to identify metals, oxides, minerals, soils, and foods. The attempts to obtain calorimetric data from DTA instruments eventually led to the development of DSC. The term differential scanning calorimetry and the acronym DSC were coined in 1963 when the first commercial instrument of this type became available. This apparatus was easy to operate, enabled fast experiments, and required only small samples (typically 5–10 mg). Its importance for materials characterization was immediately demonstrated and the DSC technique soon experienced a boom. New user-friendly commercial instruments were developed, and new applications were explored. It is, however, somewhat ironic that the method ows its still growing popularity to analytical rather than calorimetric uses.


2001 ◽  
Vol 674 ◽  
Author(s):  
Xiang-Cheng Sun ◽  
J. A. Toledo ◽  
S. Galindo ◽  
W. S. Sun

ABSTRACTFerromagnetic properties and nanocrystallization process of soft ferromagnetic (Fe0.99Mo0.01)78Si9B13 ribbons are studied by transmission electron microscope (TEM), X-ray diffraction (XRD), Mössbauer spectroscopy (MS), differential scanning calorimeters (DSC) and magnetization measurements. The Curie and crystallization temperature are determined to be TC=665K and Tx = 750K, respectively. The Tx value is in well agreement with DSC measurement results. X-ray diffraction patterns had shown a good reconfirm of two metastable phases (Fe23B6, Fe3B) were formed under in-situ nanocrystallization process. Of which these metastable phases embedded in the amorphous matrix have a significant effect on magnetic ordering. The ultimate nanocrystalline phases of α-Fe (Mo, Si) and Fe2B at optimum annealing temperature had been observed respectively. It is notable that the magnetization of the amorphous phase decreases more rapidly with increasing temperature than those of nanocrystalline ferromagnetism, suggesting the presence of the distribution of exchange interaction in the amorphous phase or high metalloid contents.


Sign in / Sign up

Export Citation Format

Share Document