Ion-pair extraction and GC–MS determination of linear alkylbenzene sulphonates in aqueous environmental samples

Talanta ◽  
2007 ◽  
Vol 71 (1) ◽  
pp. 471-478 ◽  
Author(s):  
Mehmet Akyüz
2005 ◽  
Vol 2 (3) ◽  
pp. 187-192 ◽  
Author(s):  
K. M. Reddy ◽  
K. Suvardhan ◽  
K. Suresh Kumar ◽  
D. Rekha ◽  
P. Chiranjeevi

A new simple and selective spectrophotometric method is developed for the determination of malathion by using Gention violet is described. The method was based on the alkaline hydrolysis of malathion in presence of sodium ethoxide to form sodium dimethyl dithiophosphate (Na-DMDTP). The Na-DMDTP was formed as an ion-pair complex with cationic dye, gention violet. The ion-pair complex was extracted into chloroform. The color of the organic layer was measured at 587 nm. The method was applied to the determination of malathion residues in water, grain and soil samples


2005 ◽  
Vol 2 (3) ◽  
pp. 193-198
Author(s):  
K. M. Reddy ◽  
P. Chiranjeevi

A new simple and selective spectrophotometric method is developed for the determination of dimethoate by using Azure-B is described. The method was based on the alkaline hydrolysis of dimethoate in presence of sodium ethoxide to form sodium dimethyl dithiophosphate (Na-DMDTP). The Na-DMDTP was formed as an ion-pair complex with cationic dye, azure-B. The ion-pair complex was extracted into chloroform. The color of the organic layer was measured at 535 nm. The method was applied to the determination of dimethoate residues in water, grain and soil samples.


Author(s):  
RUAA MUAYAD MAHMOOD ◽  
HAMSA MUNAM YASSEN ◽  
SAMAR , NAJWA ISSAC ABDULLA AHMED DARWEESH ◽  
NAJWA ISSAC ABDULLA

Simple, rapid and sensitive extractive spectrophotometric method is presented for the determination of glibenclamide (Glb) based on the formation of ion-pair complex between the Glb and anionic dye, methyl orange (MO) at pH 4. The yellow colored complex formed was quantitatively extracted into dichloromethane and measured at 426 nm. The colored product obeyed Beer’s law in the concentration range of (0.5-40) μg.ml-1. The value of molar absorptivity obtained from Beer’s data was found to be 31122 L.mol-1.cm-1, Sandell’s sensitivity value was calculated to be 0.0159 μg.cm-2, while the limits of detection (LOD) and quantification (LOQ) were found to be 0.1086 and 0.3292 μg.ml-1, respectively. The stoichiometry of the complex created between the Glb and MO was 1:1 as determined via Job’s method of continuous variation and mole ratio method. The method was successfully applied for the analysis of pharmaceutical formulation.


Sign in / Sign up

Export Citation Format

Share Document