scholarly journals Evaluation of a novel test method for the determination of strain rate-dependent material properties of high-performance fibers

2019 ◽  
Vol 17 ◽  
pp. 942-948
Author(s):  
Reimar Unger ◽  
Andreas Nocke ◽  
Gerald Gerlach ◽  
Chokri Cherif
2020 ◽  
Vol 62 (6) ◽  
pp. 573-583
Author(s):  
Andreas Lutz ◽  
Lukas Huber ◽  
Claus Emmelmann

2008 ◽  
Vol 400-402 ◽  
pp. 137-143 ◽  
Author(s):  
Vinod Rajayogan ◽  
Obada Kayali

Determination of a realistic model for the estimation of autogenous shrinkage in plain cement mixtures has been an ongoing research among researchers in high performance concrete. While no standard test method exists for the determination of autogenous shrinkage, various researchers have designed different test methods for measurement of autogenous shrinkage. Current study involved the experimental determination of autogenous shrinkage using the test method developed by O.M.Jensen and co-workers, complimented with non-contact eddy current sensors. Measurements were conducted from as early as 1.5 hours from the time of casting. The samples were placed in a constant temperature chamber and the temperature of the sample was also monitored using a thermocouple. The study was carried out on plain cement mixtures at three water cement ratios of 0.25, 0.32 and 0.38. Measurements were also conducted on simple sealed prismatic samples but these measurements could only be collected after 24 hours of casting. The work is supplemented with CEMHYD3D simulations of the samples at similar water-cement ratios under sealed conditions so as to understand the development of the microstructure of the cement responsible for autogenous shrinkage. While experimental determination of internal relative humidity is quite difficult, data regarding chemical shrinkage, amount of water left and the development of the discontinuous capillary network from the simulations help to understand the determined experimental values of autogenous shrinkage. A detailed explanation on the causes of autogenous shrinkage and the basic mechanism responsible for it has been presented.


2020 ◽  
Vol 404 ◽  
pp. 45-52
Author(s):  
Antonios Bouzakis ◽  
Georgios Skordaris ◽  
Konstantinos Dionysios Bouzakis ◽  
Mehmet Gökhan Gökcen ◽  
Apostolos Boumpakis ◽  
...  

Recently, stress, strain, strain-rate dependent curves for cemented carbide have become an established tool for evaluating the mechanical properties. In this paper, related strain-rate dependent data of a K05 insert were employed to define the developed stress and strain fields occurring in the compound coating-substrate at impact forces of various durations. In this way, the occurring maximum strains at various impact loads and times were analytically calculated. These maximum values and related fatigue endurance coating strain-rate dependent limits were consequently used to validate published coating fatigue critical impact forces associated with certain impact times.


2019 ◽  
Vol 89 (18) ◽  
pp. 3825-3838
Author(s):  
Ahmad Abuobaid ◽  
Raja Ganesh ◽  
John W Gillespie

A dynamic loop test method for measuring strain rate-dependent fiber properties was developed. During dynamic loop testing, the fiber ends are accelerated at constant levels of 20.8, 50 and 343 m/s2. The test method is used to study Kevlar® KM2-600, which fails in axial compression due to kink band formation. The compressive failure strain and strain rate at the onset of kink band formation is calculated from the critical loop diameter ( D C), which is monitored throughout the test using a high-speed camera. The results showed that compressive failure strain increases with strain rates from quasi-static to a maximum strain rate of 116 s−1 by a factor of ∼3. Kink angles (φ) and kink band spacing ( D S) were 60 ° ± 2 ° and 16 ± 3 μm, respectively, over the strain rates tested. Rate-dependent mechanisms of compressive failure by kink band formation were discussed.