scholarly journals Experimental Study on Dynamic Thermal Response of Building Attached Photovoltaic (BAPV) Curtain Wall System

2017 ◽  
Vol 205 ◽  
pp. 314-320 ◽  
Author(s):  
Chao Zhou ◽  
Ruobing Liang ◽  
Jili Zhang ◽  
Ahmad Riaz
2017 ◽  
Vol 865 ◽  
pp. 383-389 ◽  
Author(s):  
Min Jung Bae ◽  
Yu Min Kim ◽  
Gyeong Seok Choi ◽  
Jae Sik Kang ◽  
Hyun Jung Choi

With the window rating system being enforced, window companies are required to assign window ratings to their products. As the window ratings is based on the experimental results of fenestration, they are required to spend a lot of time and money conducting laboratory tests in order to assign window ratings to all their products. Through the window performance evaluation system using simulation, the thermal transmittance of products calculated based on numerical simulation can be used in place of experimental results to obtain the window rating. To ensure the credibility of simulation results, it is necessary to use the correct evaluation methods and primary information derived from in use practice should be available for the numerical simulation. The purpose of this paper is to investigate the evaluation methods that the simulator actually uses for the thermal performance of fenestration in WINDOW/THERM. The evaluation methods used by twenty-one simulators were investigated using primary evaluation methods for numerical simulation as the criteria. This study found that most of the simulation results were not trustworthy even though they were similar to experimental results because the evaluation methods used by simulators are incorrect. Furthermore, to enhance the credibility of simulation results, the simulator should be provided with the detailed information used in practice related to the evaluation performance of numerical simulation.


2015 ◽  
Vol 725-726 ◽  
pp. 71-79
Author(s):  
Mikhail Petrichenko ◽  
Darya Nemova ◽  
Arina Bogomolova ◽  
Anastasiya Kopylova

The main function of walling system is to protect from environmental impact and to create favorable climate indoors. At the present time people use such tape of structures, such as: wall with silicate brick veneer, curtain wall system with a thin plaster layer and curtain wall system with air gap as well as without it. The results of the thermomoist calculation of enclosing structures with silicate brick veneer without air gap is presented in article. Technical guidelines for normalization of humidity conditions for data structures are provided in article. The main purpose is to calculate and to develop design consideration for realization enclosing structures with silicate brick veneer without air gap. The results of the calculation show conformity of the walling system to the required energy efficiency, hygiene and comfort standards.


Sign in / Sign up

Export Citation Format

Share Document