scholarly journals Power Flow Studies for Assessment the Security of Steady States in Zone Inside the Large Interconnected Power System

2017 ◽  
Vol 104 ◽  
pp. 421-428 ◽  
Author(s):  
Timurs Kuznecovs ◽  
Anatolijs Mahnitko ◽  
Antans Sauhats ◽  
Vladislav Oboskalov
Energies ◽  
2019 ◽  
Vol 12 (2) ◽  
pp. 322 ◽  
Author(s):  
Ping He ◽  
Seyed Arefifar ◽  
Congshan Li ◽  
Fushuan Wen ◽  
Yuqi Ji ◽  
...  

The well-developed unified power flow controller (UPFC) has demonstrated its capability in providing voltage support and improving power system stability. The objective of this paper is to demonstrate the capability of the UPFC in mitigating oscillations in a wind farm integrated power system by employing eigenvalue analysis and dynamic time-domain simulation approaches. For this purpose, a power oscillation damping controller (PODC) of the UPFC is designed for damping oscillations caused by disturbances in a given interconnected power system, including the change in tie-line power, the changes of wind power outputs, and others. Simulations are carried out for two sample power systems, i.e., a four-machine system and an eight-machine system, for demonstration. Numerous eigenvalue analysis and dynamic time-domain simulation results confirm that the UPFC equipped with the designed PODC can effectively suppress oscillations of power systems under various disturbance scenarios.


Load frequency control (LFC) in interconnected power system of small distribution generation (DG) for reliability in distribution system. The main objective is to performance evaluation load frequency control of hybrid for interconnected two-area power systems. The simulation consist of solar farm 10 MW and gasifier plant 300 kW two-area in tie line. This impact LFC can be address as a problem on how to effectively utilize the total tie-line power flow at small DG. To performance evaluation and improve that defect of LFC, the power flow of two-areas LFC system have been carefully studied, such that, the power flow and power stability is partially LFC of small DG of hybrid for interconnected two-areas power systems. Namely, the controller and structural properties of the multi-areas LFC system are similar to the properties of hybrid for interconnected two-area LFC system. Inspired by the above properties, the controller that is propose to design some proportional-integral-derivative (PID) control laws for the two-areas LFC system successfully works out the aforementioned problem. The power system of renewable of solar farm and gasifier plant in interconnected distribution power system of area in tie – line have simulation parameter by PID controller. Simulation results showed that 3 types of the controller have deviation frequency about 0.025 Hz when tie-line load changed 1 MW and large disturbance respectively. From interconnected power system the steady state time respond is 5.2 seconds for non-controller system, 4.3 seconds for automatic voltage regulator (AVR) and 1.4 seconds for under controlled system at 0.01 per unit (p.u.) with PID controller. Therefore, the PID control has the better efficiency non-controller 28 % and AVR 15 %. The result of simulation in research to be interconnected distribution power system substation of area in tie - line control for little generate storage for grid connected at better efficiency and optimization of renewable for hybrid. It can be conclude that this study can use for applying to the distribution power system to increase efficiency and power system stability of area in tie – line.


IEEE Access ◽  
2020 ◽  
Vol 8 ◽  
pp. 18036-18063 ◽  
Author(s):  
Imdadullah ◽  
Syed Muhammad Amrr ◽  
M. S. Jamil Asghar ◽  
Imtiaz Ashraf ◽  
Mohammad Meraj

2014 ◽  
Vol 536-537 ◽  
pp. 1542-1546
Author(s):  
Xun Gao ◽  
Jie Meng ◽  
Yi Qun Li ◽  
Ying Wang ◽  
Wen Chao Zhang

A phenomenon that the damping ratio will decrease when the power flows from both sides to the primary power grid is summarized and analyzed in the paper. Based on analysis of the damping ratio change of West Inner Mongolia-Shandong oscillation under the sequential operation mode and the hedge operation mode, a three-machine equivalent system is established to study edge to edge (ETE) oscillation mode under hedge operating mode of the power system. The influence of magnitudes and trends of power flow on damping ratio is analyzed, and the reason that why damping ratios decreases when both sides send power to the mid-side power grid is explained.


2010 ◽  
Vol 59 (3-4) ◽  
pp. 121-140 ◽  
Author(s):  
Łukasz Nogal ◽  
Jan Machowski

WAMS - based control of series FACTS devices installed in tie-lines of interconnected power systemThis paper addresses the state-variable stabilising control of the power system using such series FACTS devices as TCPAR installed in the tie-line connecting control areas in an interconnected power system. This stabilising control is activated in the transient state and is supplementary with respect to the main steady-state control designed for power flow regulation. Stabilising control laws, proposed in this paper, have been derived for a linear multi-machine system model using direct Lyapunov method with the aim to maximise the rate of energy dissipation during power swings and therefore maximisation their damping. The proposed control strategy is executed by a multi-loop controller with frequency deviations in all control areas used as the input signals. Validity of the proposed state-variable control has been confirmed by modal analysis and by computer simulation for a multi-machine test system.


2020 ◽  
pp. 37-46
Author(s):  
B. Ayuev ◽  
V. Davydov ◽  
P. Erokhin ◽  
V. Neuymin ◽  
A. Pazderin

Steady-state equations play a fundamental role in the theory of power systems and computation practice. These equations are directly or mediately used almost in all areas of the power system state theory, constituting its basis. This two-part study deals with a geometrical interpretation of steady-state solutions in a power space. Part I considers steady states of the power system as a surface in the power space. A power flow feasibility region is shown to be widely used in power system theories. This region is a projection of this surface along the axis of a slack bus active power onto a subspace of other buses power. The findings have revealed that the obtained power flow feasibility regions, as well as marginal states of the power system, depend on a slack bus location. Part II is devoted to an analytical study of the power surface of power system steady states.


2018 ◽  
Vol 7 (2.6) ◽  
pp. 130 ◽  
Author(s):  
Hayder O. Alwan ◽  
Noor M. Farhan

Outages and faults cause problems in interconnected power system with huge economic consequences in modern societies. In the power system blackouts, black start resources such as micro combined heat and power (CHP) systems and renewable energies, due to their self-start ability, are one of the solutions to restore power system as quickly as possible. In this paper, we propose a model for power system restoration considering CHP systems and renewable energy sources as being available in blackout states. We define a control variable representing a level of balance between the distance and importance of loads according to the importance and urgency of the affected customer. Dynamic power flow is considered in order to find feasible sequence and combination of loads for load restoration.


2018 ◽  
Vol 7 (2.8) ◽  
pp. 18
Author(s):  
B Vijaya Krishna ◽  
B Venkata Prashanth ◽  
P Sujatha

In current days, the power quality issues in the interconnected power system are mainly happens due to the demand of electricity and utilization of large non-linear loads as well as inductive/capacitive loads. The power quality cries are voltage sag and swell in multi-bus power system (MBPS). In this article studies on a two bus, three bus and five bus power systems using DPFC. In order to eliminate the voltage sag and swell in the MBPS, a distributed power flow controller (DPFC) is designed. The structure of the DPFC consists of three-phase shunt converter and three single series phase converters. Both these converters are arranged in back-back voltage source inverters (VSIs). These converters are controlled with help of the pulse width modulation (PWM) scheme. The feedback controllers and reference signals are derived the PWM for DPFC to magnify the power quality problems in MBPS. The performance of the model is investigated at different loads by making of MATLAB/Simulink model. The simulation results are presented.