Single-stage accelerator mass spectrometer radiocarbon-interference identification and positive-ionisation characterisation

Author(s):  
K.M. Wilcken ◽  
S.P.H.T. Freeman ◽  
S. Xu ◽  
A. Dougans
Radiocarbon ◽  
2019 ◽  
Vol 61 (5) ◽  
pp. 1511-1516
Author(s):  
Ming He ◽  
Yijun Pang ◽  
Yiwen Bao ◽  
Kangning Li ◽  
Shan Jiang ◽  
...  

ABSTRACTThe second home-made single stage accelerator mass spectrometer (SSAMS) system dedicated to radiocarbon (14C) measurements was built after the first SSAMS system was moved to Guangxi Normal University. With some improvements to the second SSAMS system, the performance has been improved. With the conditions of total ion energy of 200KeV, ions charge states of 1+ and helium as stripper gas, 14C measurements with precision of 0.5% and a background level of 0.5 pMC were achieved. Details of the system and the experimental performance are given here.


Author(s):  
Stewart P.H.T. Freeman ◽  
Andrew Dougans ◽  
Lanny McHargue ◽  
Klaus M. Wilcken ◽  
Sheng Xu

Author(s):  
Richard P. Shanks ◽  
Philippa L. Ascough ◽  
Andrew Dougans ◽  
Paul Gallacher ◽  
Pauline Gulliver ◽  
...  

Radiocarbon ◽  
2010 ◽  
Vol 52 (2) ◽  
pp. 263-271 ◽  
Author(s):  
P Naysmith ◽  
G T Cook ◽  
S P H T Freeman ◽  
E M Scott ◽  
R Anderson ◽  
...  

In 2003, a National Electrostatics Corporation (NEC) 5MV tandem accelerator mass spectrometer was installed at SUERC, providing the radiocarbon laboratory with 14C measurements to 4–5‰ repeatability. In 2007, a 250kV single-stage accelerator mass spectrometer (SSAMS) was added to provide additional 14C capability and is now the preferred system for 14C analysis. Changes to the technology and to our operations are evident in our copious quality assurance data: typically, we now use the 134-position MC-SNICS source, which is filled to capacity. Measurement of standards shows that spectrometer running without the complication of on-line δ13C evaluation is a good operational compromise. Currently, 3‰ 14C/13C measurements are routinely achieved for samples up to nearly 3 half-lives old by consistent sample preparation and an automated data acquisition algorithm with sample random access for measurement repeats. Background and known-age standard data are presented for the period 2003–2008 for the 5MV system and 2007–2008 for the SSAMS, to demonstrate the improvements in data quality.


2018 ◽  
Author(s):  
S. Rastigeev ◽  
A. Frolov ◽  
A. Goncharov ◽  
V. Klyuev ◽  
E. Konstantinov ◽  
...  

2016 ◽  
Vol 13 (7) ◽  
pp. 923-926 ◽  
Author(s):  
S. A. Rastigeev ◽  
A. D. Goncharov ◽  
V. F. Klyuev ◽  
E. S. Konstantinov ◽  
L. A. Kutnyakova ◽  
...  

Radiocarbon ◽  
1992 ◽  
Vol 34 (3) ◽  
pp. 478-482 ◽  
Author(s):  
K. F. Von Reden ◽  
G. A. Jones ◽  
R. J. Schneider ◽  
A. P. McNichol ◽  
G. J. Cohen ◽  
...  

Start-up performance and first results of the new Woods Hole Accelerator Mass Spectrometer are discussed. Special attention is given to the hemispherical ionizer sputter source and the triple-isotope injector design.


Sign in / Sign up

Export Citation Format

Share Document