Some practical realizations of preset time count rate meters using optimized adaptive digital signal-processing solutions

Author(s):  
Aleksandar Zigic
2005 ◽  
Vol 18 (3) ◽  
pp. 559-570
Author(s):  
Aleksandar Zigic ◽  
Vojislav Arandjelovic ◽  
Ðordje Saponjic ◽  
Ivana Veselinovic

Two optimized adaptive digital signal processors were implemented to the preset time count rate meters. Three mean count rate meters, based on the developed adaptive digital signal processors, were realized and were used for experimental validation of proposed adaptive digital signal processors. The experimental results, conducted without and with radioisotope for the specified errors of 10% and 5%, showed to agree well with theoretical predictions.


2005 ◽  
Vol 20 (2) ◽  
pp. 40-44
Author(s):  
Aleksandar Zigic

Experimental verifications of two optimized adaptive digital signal processing algorithms implemented in two pre set time count rate meters were per formed ac cording to appropriate standards. The random pulse generator realized using a personal computer, was used as an artificial radiation source for preliminary system tests and performance evaluations of the pro posed algorithms. Then measurement results for background radiation levels were obtained. Finally, measurements with a natural radiation source radioisotope 90Sr-90Y, were carried out. Measurement results, con ducted without and with radio isotopes for the specified errors of 10% and 5% showed to agree well with theoretical predictions.


2019 ◽  
pp. 34-39 ◽  
Author(s):  
E.I. Chernov ◽  
N.E. Sobolev ◽  
A.A. Bondarchuk ◽  
L.E. Aristarhova

The concept of hidden correlation of noise signals is introduced. The existence of a hidden correlation between narrowband noise signals isolated simultaneously from broadband band-limited noise is theoretically proved. A method for estimating the latent correlation of narrowband noise signals has been developed and experimentally investigated. As a result of the experiment, where a time frag ent of band-limited noise, the basis of which is shot noise, is used as the studied signal, it is established: when applying the Pearson criterion, there is practically no correlation between the signal at the Central frequency and the sum of signals at mirror frequencies; when applying the proposed method for the analysis of the same signals, a strong hidden correlation is found. The proposed method is useful for researchers, engineers and metrologists engaged in digital signal processing, as well as developers of measuring instruments using a new technology for isolating a useful signal from noise – the method of mirror noise images.