Importance of test parameters, specimen type and use configuration on the identification of Sn/Ag solder behaviour laws

2018 ◽  
Vol 82 ◽  
pp. 213-223
Author(s):  
Carmen Martin ◽  
Alexandre Micol ◽  
François Pérès
2012 ◽  
Vol 4 (1) ◽  
pp. 1
Author(s):  
Djoko Purwanto

Timber Acacia mangium (Acacia mangium, Willd) for Furniture. The study aims to determine the mechanical and physical properties and the decorative value (color and fiber) wood of acacia mangium with using finishing materials. This type of finishing material used is ultran lasur natural dof ,ultran lasur classic teak, aqua politur clear dof, aqua politur akasia dan aqua politur cherry. After finishing the wood is stored for 3 months. Test parameters were observed, namely, physical and mechanical properties of wood, adhesion of finishing materials, color and appearance of the fiber, and timber dimensions expansion. The results showed that the mechanical physical properties of acacia wood qualified SNI. 01-0608-89 about the physical and mechanical properties of wood for furniture, air dry the moisture content from 13.78 to 14.89%, flexural strength from 509.25 to 680.50 kg/cm2, and compressive strength parallel to fiber 342.1 - 412.9 kg/cm2. Finishing the treatment process using five types of finishing materials can increase the decorative value (color and fiber) wood. Before finishing the process of acacia mangium wood has the appearance of colors and fibers and less attractive (scale scores 2-3), after finishing acacia wood fibers have the appearance of colors and interesting and very interesting (scale 4-5).Keywords: mangium wood, mechanical properties, decorative value, finishing, furniture.


2010 ◽  
Vol 2 (2) ◽  
pp. 8
Author(s):  
Evy Setiawati

Rattan on frequently attacked by the powder post beetle (Tellu, 2001). The prevention of dry powder attacks is done by preservation. The increasing resistant of rattan from insect attack can be done by an environmentally friendly preservative, the Galam wood vinegar. This research  aims to determine the most effective concentration of preservative that shows the lowest attacks level of D. Farb minutus powder. The rattan used is green rattan (Calamus sp.) The concentration of preservative that are used:10%, 40%, 70% and 100%. The testing of dry powder attack  used force feedback method. The effectiveness test parameters of wood vinegar to dry powder attacks  included degree of protection Dinoderus minutus Farb. powder,  reduction percentage of rattan weight and the mortality of dry powder Dinoderus sp for toxicological testing of wood vinegar. The test results showed that the degree of protection powder in rattan growing along with the increased concentration of preservatives. The higher the concentration of  wood vinegar, the smaller the reduction of rattan weight and the higher the mortality rate of dry powder. Keywords: resistant of rattan, wood vinegar, Dinoderus minutus.


2018 ◽  
Vol 60 (7-8) ◽  
pp. 679-686 ◽  
Author(s):  
Jim Floor ◽  
Bas van Deursen ◽  
Erik Tempelman

2017 ◽  
pp. 95-98
Author(s):  
N. L. Venediktov ◽  
A. N. Venediktov ◽  
I. M. Kovenskiy

The experimental laboratory-scale plant for the fatigue testing of samples with electrolytic coating were designed and constructed. Shows the kinematic scheme and considered the principle of the plant. The dependences for determination of test parameters and the method of testing samples with coatings under variable loads were obtained.


Author(s):  
J. Shi

Scatter in test results is common for relatively brittle materials such as ceramic matrix composites. The scatter may come from differences in material processing conditions, specimen machining/handling and from variations in test parameters for nominally the same test material. Large scatter in test results makes material modeling difficult. In the past, master curve concepts have been proposed to reduce scatter in tensile data and to interpret fatigue/creep results. In this paper, one such concept is examined in detail by applying it to the recent tensile test results of a SiC/SiC composite. It was found that the way to construct master curves did not apply to the CMC studied and thus a new master curve was developed to better represent the tensile data. In addition, the test data were analysed statistically based on the new master curve.


2021 ◽  
Vol 11 (11) ◽  
pp. 5294
Author(s):  
Peer Decker ◽  
Ines Zerbin ◽  
Luisa Marzoli ◽  
Marcel Rosefort

Two different intergranular corrosion tests were performed on EN AW-6016 sheet material, an ISO 11846:1995-based test with varying solution amounts and acid concentrations, and a standard test of an automotive company (PV1113, VW-Audi). The average intergranular corrosion depth was determined via optical microscopy. The differences in the intergranular corrosion depths were then discussed with regard to the applicability and quality of the two different test methods. The influence of varying test parameters for ISO 11846:1995 was discussed as well. The determined IGC depths were found to be strongly dependent on the testing parameters, which will therefore have a pronounced influence on the determined IGC susceptibility of a material. In general, ISO 11846:1995 tests resulted in a significantly lower corrosion speed, and the corrosive attack was found to be primarily along grain boundaries.


Materials ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3074
Author(s):  
Kaveh Torkashvand ◽  
Vinod Krishna Selpol ◽  
Mohit Gupta ◽  
Shrikant Joshi

Sliding wear performance of thermal spray WC-based coatings has been widely studied. However, there is no systematic investigation on the influence of test conditions on wear behaviour of these coatings. In order to have a good understanding of the effect of test parameters on sliding wear test performance of HVAF-sprayed WC–CoCr coatings, ball-on-disc tests were conducted under varying test conditions, including different angular velocities, loads and sliding distances. Under normal load of 20 N and sliding distance of 5 km (used as ‘reference’ conditions), it was shown that, despite changes in angular velocity (from 1333 rpm up to 2400 rpm), specific wear rate values experienced no major variation. No major change was observed in specific wear rate values even upon increasing the load from 20 N to 40 N and sliding distance from 5 km to 10 km, and no significant change was noted in the prevailing wear mechanism, either. Results suggest that no dramatic changes in applicable wear regime occur over the window of test parameters investigated. Consequently, the findings of this study inspire confidence in utilizing test conditions within the above range to rank different WC-based coatings.


2012 ◽  
Vol 28 ◽  
pp. e2-e3
Author(s):  
B.C.F. Barreto ◽  
L.H.A. Raposo ◽  
S.J.B. Sousa ◽  
A.G. Pereira ◽  
A. Versluis ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document