Computational Investigation of Flow Separation over NACA 23024 Airfoil at 6 Million Free Stream Reynolds Number Using k-Epsilon Turbulence Model

2018 ◽  
Vol 5 (5) ◽  
pp. 12632-12640 ◽  
Author(s):  
B.S. Anil Kumar ◽  
Ramalingaiah ◽  
S. Manjunath ◽  
Rudresh Ganganna
Author(s):  
M. Tadjfar ◽  
D. J. Kamari

Abstract The effects of applying a coupled unsteady blowing and suction combination over SD7003 airfoil at Reynolds number of 60,000 at an angle of attack of 13°, where a large separation on the suction side of the airfoil existed, was considered to investigate active flow control (AFC) mechanism. URANS equations were employed to solve the flow field and k–ω SST was used as the turbulence model. The unsteady blowing and suction were implemented at an angle to the surface crossing the boundary layer (CBL). The influence of location and frequency of the blowing/suction jets were examined.


Author(s):  
Mahmoud Ardebili ◽  
Yiannis Andreopoulos

An experimental investigation of a separated boundary layer flow has been attempted which has been created by perturbing a flat plate flow with a favorable pressure gradient immediately followed by an adverse pressure gradient. The aim of the research program is possible control of flow separation by means of free stream turbulence. The flow is configured in a large-scale low speed wind tunnel where measurements of turbulence can be obtained with high spatial and temporal resolution. A model has been designed by using CFD analysis. Mean wall pressure and vorticity flux measurements are reported in this paper. Twelve experiments with three different mesh size grids at three different Reynolds numbers have been carried out. Three bulk flow parameters seem to characterize the flow: The Reynolds number of the boundary layer, Re+, the Reynolds number of the flow through the grid, ReM, and the solidity of the grid. It was found that the pressure coefficient depends weakly on the solidity of the grids. Vorticity flux also depends on the grid used to generate free stream turbulence. The location of maximum or minimum vorticity flux moves upstream at higher ReM.


Author(s):  
Johannes Ruhland ◽  
Christian Breitsamter

AbstractThis study presents two-dimensional aerodynamic investigations of various high-lift configuration settings concerning the deflection angles of droop nose, spoiler and flap in the context of enhancing the high-lift performance by dynamic flap movement. The investigations highlight the impact of a periodically oscillating trailing edge flap on lift, drag and flow separation of the high-lift configuration by numerical simulations. The computations are conducted with regard to the variation of the parameters reduced frequency and the position of the rotational axis. The numerical flow simulations are conducted on a block-structured grid using Reynolds Averaged Navier Stokes simulations employing the shear stress transport $$k-\omega $$ k - ω turbulence model. The feature Dynamic Mesh Motion implements the motion of the oscillating flap. Regarding low-speed wind tunnel testing for a Reynolds number of $$0.5 \times 10^{6}$$ 0.5 × 10 6 the flap movement around a dropped hinge point, which is located outside the flap, offers benefits with regard to additional lift and delayed flow separation at the flap compared to a flap movement around a hinge point, which is located at 15 % of the flap chord length. Flow separation can be suppressed beyond the maximum static flap deflection angle. By means of an oscillating flap around the dropped hinge point, it is possible to reattach a separated flow at the flap and to keep it attached further on. For a Reynolds number of $$20 \times 10^6$$ 20 × 10 6 , reflecting full scale flight conditions, additional lift is generated for both rotational axis positions.


Author(s):  
Karsten Tawackolian ◽  
Martin Kriegel

AbstractThis study looks to find a suitable turbulence model for calculating pressure losses of ventilation components. In building ventilation, the most relevant Reynolds number range is between 3×104 and 6×105, depending on the duct dimensions and airflow rates. Pressure loss coefficients can increase considerably for some components at Reynolds numbers below 2×105. An initial survey of popular turbulence models was conducted for a selected test case of a bend with such a strong Reynolds number dependence. Most of the turbulence models failed in reproducing this dependence and predicted curve progressions that were too flat and only applicable for higher Reynolds numbers. Viscous effects near walls played an important role in the present simulations. In turbulence modelling, near-wall damping functions are used to account for this influence. A model that implements near-wall modelling is the lag elliptic blending k-ε model. This model gave reasonable predictions for pressure loss coefficients at lower Reynolds numbers. Another example is the low Reynolds number k-ε turbulence model of Wilcox (LRN). The modification uses damping functions and was initially developed for simulating profiles such as aircraft wings. It has not been widely used for internal flows such as air duct flows. Based on selected reference cases, the three closure coefficients of the LRN model were adapted in this work to simulate ventilation components. Improved predictions were obtained with new coefficients (LRNM model). This underlined that low Reynolds number effects are relevant in ventilation ductworks and give first insights for suitable turbulence models for this application. Both the lag elliptic blending model and the modified LRNM model predicted the pressure losses relatively well for the test case where the other tested models failed.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Burak Karadag ◽  
Cem Kolbakir ◽  
Ahmet Selim Durna

Purpose This paper aims to investigate the effects of a dielectric barrier discharge (DBD) plasma actuator (PA) qualitatively on aerodynamic characteristics of a 3 D-printed NACA 4412 airfoil model. Design/methodology/approach Airflow visualization study was performed at a Reynolds number of 35,000 in a small-scale open-loop wind tunnel. The effect of plasma actuation on flow separation was compared for the DBD PA with four different electrode configurations at 10°, 20° and 30° angles of attack. Findings Plasma activation may delay the onset of flow separation up to 6° and decreases the boundary layer thickness. The effects of plasma diminish as the angle of attack increases. Streamwise electrode configuration, in which electric wind is produced in a direction perpendicular to the freestream, is more effective in the reattachment of the airflow compared to the spanwise electrode configuration, in which the electric wind and the free stream are in the same direction. Practical implications The Reynolds number is much smaller than that in cruise aircraft conditions; however, the results are promising for low-velocity subsonic airflows such as improving control capabilities of unmanned aerial vehicles. Originality/value Superior efficacy of spanwise-generated electric wind over streamwise-generated one is demonstrated at a very low Reynolds number. The results in the plasma aerodynamics literature can be reproduced using ultra-low-cost off-the-shelf components. This is important because high voltage power amplifiers that are frequently encountered in the literature may be prohibitively expensive especially for resource-limited university aerodynamics laboratories.