scholarly journals A novel method on single crystallization of h-BN coated tungsten tip using to a point electron source

2017 ◽  
Vol 4 (7) ◽  
pp. 7025-7031
Author(s):  
Shigeki Hayashi ◽  
Issei Kobayashi ◽  
Ryo Onoyama ◽  
Yota Kano ◽  
Yussei Yoshida
Author(s):  
P.H. McLaughlin

A shelved structure for the support of an electron optical column affords advantages both to the designer and the user. A lens may be removed for cleaning for example, without demounting the remaining lenses. A custom device for another example, may be placed on a shelf, substituting for the standard lens perhaps so that some specialized research may be undertaken. Especially advantageous is a shelved arrangement if the column assembly is designed to hang from a supporting structure such as a gas borne floating platform, as is the case with the system described below.As shown on the schematic, a floating platform (I) supports the electron source apparatus (2) and a U-shaped column support shelf (3). The column support shelf acts as a key for locating and supporting three struts (4) which with nuts (5) support the condenser shelf (6), the objective shelf (7), the upper projector shelf (8), and the lower projector shelf (9).


Author(s):  
A. Strojnik ◽  
J.W. Scholl ◽  
V. Bevc

The electron accelerator, as inserted between the electron source (injector) and the imaging column of the HVEM, is usually a strong lens and should be optimized in order to ensure high brightness over a wide range of accelerating voltages and illuminating conditions. This is especially true in the case of the STEM where the brightness directly determines the highest resolution attainable. In the past, the optical behavior of accelerators was usually determined for a particular configuration. During the development of the accelerator for the Arizona 1 MEV STEM, systematic investigation was made of the major optical properties for a variety of electrode configurations, number of stages N, accelerating voltages, 1 and 10 MEV, and a range of injection voltages ϕ0 = 1, 3, 10, 30, 100, 300 kV).


Author(s):  
M. Iwatsuki ◽  
Y. Kokubo ◽  
Y. Harada

On accout of its high brightness, small optical source size, and minimal energy spread, the field emission gun (FEG) has the advantage that it provides the conventional transmission electron microscope (TEM) with a highly coherent illumination system and directly improves the resolving power and signal-to-noise ratio of the scanning electron microscope (SEM). The FEG is generally classified into two types; the cold field emission (C-FEG) and thermal field emission gun (T-FEG). The former, in which a field emitter is used at the room temperature, was successfully developed as an electron source for the SEM. The latter, in which the emitter is heated to the temperature range of 1000-1800°K, was also proved to be very suited as an electron source for the TEM, as well as for the SEM. Some characteristics of the two types of the FEG have been studied and reported by many authors. However, the results of the respective types have been obtained separately under different experimental conditions.


Author(s):  
M.A. Gregory ◽  
G.P. Hadley

The insertion of implanted venous access systems for children undergoing prolonged courses of chemotherapy has become a common procedure in pediatric surgical oncology. While not permanently implanted, the devices are expected to remain functional until cure of the primary disease is assured. Despite careful patient selection and standardised insertion and access techniques, some devices fail. The most commonly encountered problems are colonisation of the device with bacteria and catheter occlusion. Both of these difficulties relate to the development of a biofilm within the port and catheter. The morphology and evolution of biofilms in indwelling vascular catheters is the subject of ongoing investigation. To date, however, such investigations have been confined to the examination of fragments of biofilm scraped or sonicated from sections of catheter. This report describes a novel method for the extraction of intact biofilms from indwelling catheters.15 children with Wilm’s tumour and who had received venous implants were studied. Catheters were removed because of infection (n=6) or electively at the end of chemotherapy.


GeroPsych ◽  
2012 ◽  
Vol 25 (4) ◽  
pp. 235-245 ◽  
Author(s):  
Katja Franke ◽  
Christian Gaser

We recently proposed a novel method that aggregates the multidimensional aging pattern across the brain to a single value. This method proved to provide stable and reliable estimates of brain aging – even across different scanners. While investigating longitudinal changes in BrainAGE in about 400 elderly subjects, we discovered that patients with Alzheimer’s disease and subjects who had converted to AD within 3 years showed accelerated brain atrophy by +6 years at baseline. An additional increase in BrainAGE accumulated to a score of about +9 years during follow-up. Accelerated brain aging was related to prospective cognitive decline and disease severity. In conclusion, the BrainAGE framework indicates discrepancies in brain aging and could thus serve as an indicator for cognitive functioning in the future.


2014 ◽  
Vol 62 (S 02) ◽  
Author(s):  
J. Photiadis ◽  
M. Musci ◽  
O. Miera ◽  
S. Ovroutski ◽  
A. Mekkawy ◽  
...  